How to use the OZ

Location: Place the unit on a solid surface or locate on a wall or ceiling using the locating 
holes on the unit base. Place, preferably, at high level

.

Power connection: Connect to a suitable 

230

V supply

Operation: Switch on the units using switch (C) and indicator (B)

Function

The OZ1000/2000 uses UV-C and Ozone technology to sterilise and de-odorise the air within the area it is being 
used. The special Jimco lamp/s produces UV light at a certain wavelength that has a sterilising effect whilst also 
creating a small amount of Ozone  that will eliminate odour from the air and on the surfaces within the room. Bacteria 
and Vira

 

will be greatly reduced. The OZ1000/2000 will treat fabrics as well as air.

WARNING!!!

 

The

 

OZ1000/2000

 

produces

 

more

 

than

 

the

 

permissible

 

level

 

of

 

Ozone

 

for

 

room

 

occupation

 

during

treatment.

 

The

 

unit

 

should

 

be

 

switched

 

on

 

and

 

left

 

in

 

the

 

treatment

 

area

 

for

 

the

 

required

 

length

 

of

 

time,

 

depending

on

 

level

 

of

 

pollution,

 

it

 

should

 

then

 

be

 

switched

 

off

 

and

 

left

 

for

 

approximately

 

30

 

minutes

 

before

 

re

 

occupying

permanently.

 

Ozone

 

will

 

naturally

 

turn

 

back

 

to

 

Oxygen

 

after

 

a

 

short

 

time

 

and

 

the

 

only

 

other

 

by

 

products

 

of

 

the

 

unit

are

 

Carbon

 

Dioxide

 

(CO2)

 

and

 

Water,

 

but

 

these

 

are

 

in

 

such

 

small

 

amounts

 

they

 

can

 

hardly

 

be

 

measured.

Treatment Time:

Treatment times will vary according to size of room and level of pollution. Consult your supplier for help.

Lifetime

 

of the lamps

The normal life for the lamp/s is 8,000 operating hours, this equates to 24 hours a day for one year. If the efficiency 
appears to reduce before the 8,000 hours, you may need to clean the lamp/s.(see instructions below).

To replace the lamp

Switch off and unplug the unit from the socket

Remove to top from the unit via 4 No screws (D)

Unplug the lamp from the lamp socket

Remove old lamp/s from clips (H) and replace with new lamp

Replace lamp/s socket securely and replace the top of the unit

The OZ1000/2000 is now ready to operate

Cleaning (recommended every three months if using continuously)

Switch off and unplug the unit from the socket

Remove to top from the unit via 4 No screws (D)

Wipe the outside of the lamp/s and the fan with a clean damp cloth with a little detergent

Dry carefully with a soft dry cloth

Replace top of unit

AS Friis Ltd.

34/11 Phatthana Wet 8, Sukumvit Soi 71, Khwaeng Phra Khanong Nuea, Watthana, Bangkok 10110
Tel: +66 20 95 56 95

Fax: +66 20 95 56 90

email: [email protected]

, W

ebsite:

www.as-friis.com

Warranty Regulations

On the 

OZ's series

, JIMCO A/S provides 24-month warranty. Guarantee periods is 12 months. The warranty is calculated 

from the date of sale from your JIMCO dealer. To provide this, a receipt must be kept. Within the stated warranty period, 

JIMCO A/S will cover, without charge, every defect that are subject to material or manufacturing defects and, at your option, 

provides

 

warranty repair or replacement of the 

OZ products

Prerequisite for the guarantee benefit is that the appliance is used according to its purpose and in accordance with the 

operating instructions.

Excluded from the warranty are damages caused by improper use, wear or interference on the part of the owner or third 

parties. The warranty does not cover consumables 

 

For example lamps 

 

Or wear objects as a fan and lacking which only 

negatively

 affect the value or usefulness of the OZ Products

Summary of Contents for OZ1000

Page 1: ...2000 Compact cleaner 230V version AS Friis Ltd 34 11 Phatthana Wet 8 Sukumvit Soi 71 Khwaeng Phra Khanong Nuea Watthana Bangkok 10110 Tel 66 20 95 56 95 Fax 66 20 95 56 90 email infor as friis com Website www as friis com ...

Page 2: ...ure OZ1000 2000 Ultra low operating costs OZ1000 2000 CE Marked equipment WARNING Before attempting to change the lamp or open the enclosure make sure the unit is switched off and unplugged Direct exposure to UV C light can cause damage to the eyes and sunburn 1 2 Figure 2 E Cable access F JIMCO UV lamp G Lamps socket H Lamp clips I Fan 1 1 Fig 1 A Enclosure B Power Indicator C On Off switch D Enc...

Page 3: ...e 8 000 hours you may need to clean the lamp s see instructions below To replace the lamp Switch off and unplug the unit from the socket Remove to top from the unit via 4 No screws D Unplug the lamp from the lamp socket Remove old lamp s from clips H and replace with new lamp Replace lamp s socket securely and replace the top of the unit The OZ1000 2000 is now ready to operate Cleaning recommended...

Page 4: ...99 Identification of signer Date Signature References to standards and or technical specifications which are used for this Statement of Compliance or parts thereof Harmonised standards No Version Titel Parts 1 204 1 2 Machinery Safety Electrical material on machinery EN 60 204 1 Other standards and or technical specifications No Version Titel Parts 1 Other technical solutions where detailed inform...

Page 5: ...t nr Patentpending No 1713562 AS Friis Ltd 34 11 Phatthana Wet 8 Sukumvit Soi 71 Khwaeng Phra Khanong Nuea Watthana Bangkok 10110 Tel 66 20 95 56 95 Fax 66 20 95 56 90 email infor as friis com Website www as friis com Service record Lamp exchange Line ID AS FRIIS LTD Purchase Date Serial Number ...

Reviews: