ELECTRICAL CONNECTION
CONTROLS
If hard-wiring to a fused spur, this work must be done
by a qualified electrician.
The electrical connection must be carried out in compliance
with the national regulations for electricians in force.
Before connecting the appliance to the electrical network,
make sure that the power is off.
Do not install the appliance if:
•
The power supply cable is damaged.
•
The appliance and / or the control boxes are
damaged.
The appliance supply voltage is 230V. Make sure the power
supply complies with the appliance’s voltage.
Make sure that the power supply cable never comes into
contact with the hot surface of the appliance.
This appliance must be earthed and connected to a supply
that is earthed.
If the appliance is mounted in the bathroom or shower, the
power line must be equipped with an RCD with maximum
rated current of 30mA.
In humid environments (bathrooms, kitchens, laundry
rooms etc.) it is very important that the electrical
connection to the network is situated at least at 50 cm from
the floor.
Your heater should not be operated without a control
system.
You must use either a wired or wireless thermostat depending
on your installation preference. If in doubt, ask professional
qualified personnel.
This heater is
NOT equipped with a device to control the room
temperature. Do not use this heater in small rooms when they
are occupied by persons not capable of leaving the room on
their own, unless constant supervision is provided.
WiFi connection:
A WiFi hub is required to connect the thermostats to the app.
Wired Diagram:
Wireless Diagram:
Mains
Fused Spur
Thermostat
IR Panel
Mains
Fused Spur
IR Panel
Thermostat
RF Switch