background image

DEHUMIDIFIER

Owner’s Manual

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

ENERGY STAR® qualified

units remove moisture

with less energy than

conventional

dehumidifiers.

D025B-25PT

D025B-35PT

D026B-50PT

D026B-50PT-P

Summary of Contents for D025B-25PT

Page 1: ...IDIFIER Owner s Manual KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE ENERGY STAR qualified units remove moisture with less energy than conventional dehumidifiers D025B 25PT D025B 35PT D026B 50PT D026B 50PT P ...

Page 2: ......

Page 3: ... the following safety instructions DO NOT touch the dehumidifier or the electrical plug with wet hands Always ensure effective grounding Incorrect grounding may cause electric shock Do NOT exceed the rating of the power outlet or connection device Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual Disconnect the power if strange sounds sm...

Page 4: ... children of these dangers If the unit is damaged or it malfunctions do not continue to operate it Unplug the product from the electrical outlet Refer to the troubleshooting section and contact the customer support center DO NOT cover the air inlet or outlet on the appliance as this may cause the unit to fail Do NOT place flower vases or other water containers on top of the unit Water may spill in...

Page 5: ...ea 50 or Basement 45 Digital Mirage Display Easily monitor humidity changes from across the room Adjustable Humidistat Different dehumidification levels can be selected according to different room requirements Save Money This dehumidifier is Energy Star rated and could quickly remove moisture from the air without running up your utility bill Energy Star units not only save energy for the environme...

Page 6: ...ir Flow Volume H M L 131 116 101 CFM 131 116 101 CFM 188 168 151 CFM 188 168 151 CFM Noise Leve 53dB A 53dB A 53dB A 53dB A Weight 32 lbs 34 2 lbs 39 7 lbs 40 8 lbs Dimensions W D H 13 8 W 10 2 D 19 7 H 13 8 W 10 2 D 19 7 H 15 4 W 11 3 D 24 4 H 15 4 W 11 3 D 24 4 H Energy Star Yes Yes Yes Yes These specifications are for reference only For actual data please refer to the rating label on the back o...

Page 7: ...the filter Switch the unit OFF and carefully remove the filter from the unit and clean Replace the filter and switch ON the unit Press to cycle through High Medium or Low fan modes Higher fan speeds lead to increased moisture removal When humidity has been reduced or quiet operation is preferred set the fan to Medium or Low POWER Button FILTER Button FAN SPEED Button ...

Page 8: ... hours up to 10 hours After 10 hours each press of the or buttons will increase the timer in 1 hour increments up to 24 hours Once the desired time is reached the unit will automatically turn on Timer Auto Shut Off To program the unit to automatically turn off press the TIMER button when the unit is on Each press of the or buttons will change the timer setting in 30 min increments 5 hours up to 10...

Page 9: ...bucket with both hands and pull the bucket out gently 2 Drain the collected water NOTE 1 Do not remove the float from the water bucket The water full sensor will no longer be able to detect the water level correctly without the float and water may leak from the water bucket 2 If the drainage bucket is dirty wash it with cold or lukewarm water Do not use detergent scouring pads chemically treated d...

Page 10: ...a pitch of 11 5 TPI Place dehumidifier on a level surface Unscrew the cap on the back of the unit to access the garden hose nozzle Thread a garden hose not included onto the accessible nozzle lead to a floor drain and cut to length Make sure that there are no kinks or knots in the garden hose See picture below Turn on the unit and press the MODE button until set to CONTINUOUS Garden Hose Installat...

Page 11: ...ain Adapter and turn clockwise onto the garden hose nozzle on the back of the unit as pictured below Drain adapter is included in storage compartment on top of water bucket Once securely installed lead the Drain Hose to a nearby drain sink or out of a window up to 16ft height from the base of the unit Turn on the unit and press the pump button to activate the internal pump CAUTION PUMP MODE WILL O...

Page 12: ...eria Partially fill the bucket with clean water and mild detergent Swish it around in the bucket empty and rinse Clean the air filter 1 To remove the filter pull filter outwards 2 Wash the filter with clean water then dry 3 Re install the filter replace bucket Storing the dehumidifier 1 Before storing the unit let it rest for one full day so that the system can dry out naturally 2 Clean the unit w...

Page 13: ... 41 F There is a water vapor source in the room The unit makes a loud noise when operating Air filter may be dirty Clean filter Refer to Care and Cleaning section The unit is tilted instead of upright as it should be The floor surface is not level Frost appears on the coils This is normal The dehumidifier has Auto defrost feature Water on floor Hose to connector or hose connection may be loose Int...