Page 2: ...ing i en trykbeholder skal installationen udf res i henhold til EN13445 og EN60364 El patronen placeres i beholderen med vandret indstik eller lodret indstik fra bunden El patronen m aldrig placeres i...

Page 3: ...roppen til Del 1 be st r af en m trik til bagsiden og en top til forsiden 3 Tag indholdet ud af Del 1 for at g re plads til montage af endeprop 4 Placer m trikken p inder siden af r rdelen i Del 1 S t...

Page 4: ...__________________________________________________________ 3 5 S t de tre sm skruer i in derdelen af Del 1 6 Forbind Del 1 og Del 2 som beskrevet nedenfor 7 De tre sm skruer i Del 1 passer i Del 2 Mon...

Page 5: ...ern 90 mm af isoleringen p kablet Monter 4 mm kabelsko p jordkablet Monter kabelsko p faser ne 9 Afmonter m trikken p for skruningen F r kablet gennem m trik ken og derefter gennem forskruningen 10 Va...

Page 6: ...ra Del 1 tilbage i r rdelen mens der tr kkes roligt ud i kablet 12 Sp nd forskruningen fast om kablet s kablet l ses 13 Monter Del 4 p den bne ende af Del 1 Sikr at hullerne i Del 1 og Del 4 passer in...

Page 7: ...___________________________ 6 Installationsvejledning DA Produkt Rund koblingsboks DR Varenummer 19004605 1 Monter termosikringen p beslaget ved at f lge ne denst ende procedure 2 Klem beslaget sammen...

Page 8: ..._________________________________________ 7 3 Monter de tre korte led ninger Forbind ledningerne til varmepatronen ved at l sne de tre m trikker uden laske placere led ningerne og sp nde m trikkerne i...

Page 9: ...__ 8 5 F r termosikringens f ler ned i varmepatronens f lerr r Fastsp nd de tre skruer der forbinder de to dele 6 F r de tre ledninger ind i position 11 21 og 31 7 Monter kabel til varmepa tron i den...

Page 10: ...tre ledere til termostaten s ledes Leder U 1 til position 12 p termosikringen Leder V 2 til position 22 p termosikringen Leder W 3 til position 32 p termosikringen Forbind kablets jordfor bindelse med...

Page 11: ...________________________________________________________________________________________________ 10 10 Monter l get 11 El patronen er klar til brug...

Page 12: ...______ 11 Installationsvejledning DA Produkt Rund koblingsboks ER Varenummer 19001080 19001114 19001122 1 Monter termostaten p beslaget ved at f lge ne denst ende procedure 2 Klem beslaget sammen s te...

Page 13: ...____________________________ 12 4 Monter de tre korte led ninger Forbind ledningerne til varmepatronen ved at l sne de tre m trikker placere ledningerne og sp nde m trikkerne 5 Forbind termostaten med...

Page 14: ..._______________________________________________ 13 Fastsp nd de tre skruer der forbinder delene 7 F r de tre ledninger i henholdsvis position 11 21 og 31 8 Monter varmelegemets kabel i den tilh rende...

Page 15: ...___________________________________ 14 9 Forbind jordforbindelsen fra koblingsboksens yderkappe og kablets jordforbindelse med ter mostatbeslaget hvis det valgte kabel er jordet 10 F r de tre ledere f...

Page 16: ..._ 15 11 Forbind de tre ledere i kablet til termostaten Leder U 1 til position 12 Leder V 2 til position 22 Leder W 3 til position 32 12 F r koblingsboksens yderkappe i bund S rg for at ledningerne i b...

Page 17: ..._________________________________ 16 Installationsvejledning DA Produkt Rund koblingsboks OR Varenummer 19004600 1 Monter termosikringen p beslaget ved at f lge ne denst ende procedure 2 Klem beslaget...

Page 18: ..._______________________________________________________ 17 3 Fastsp nd termosikrin gen med den medf lgen de messingm trik 4 Fastsp nd den ubrugte f letr d til beslagets side med kabelbindere 5 Forbind...

Page 19: ...______________________________________________ 18 6 F r termosikringens f ler ned i varmepatronens f lerr r 7 Forbind jordforbindelsen fra koblingsboksens yderkappe gennem for skruningen med ter mosik...

Page 20: ...skal for syne varmepatronen gennem den anden for skruning Forbind kablets jordfor bindelse til termosik ringsbeslaget hvis det valgte kabel er jordet 10 Forbind kablet til varme patronen ved at 1 l sn...

Page 21: ...______________ 20 11 Forbind termosikringsbe slaget med varmepatro nen ved at fastsp nde termosikringsbeslagets tre skruer til varmepatro nen 12 F r koblingsboksens yderkappe i bund og s rg for at led...

Page 22: ..._________________________________________ 21 Installationsvejledning DA Produkt Rund koblingsboks MR Varenummer 19001006 19001015 19001031 Procedure 1 Monter termostaten p beslaget 2 Klem beslaget sam...

Page 23: ...__________________________________________________ 22 3 Fastsp nd termostaten med de to skruer 4 Forbind termostaten med varmepatronen s ledes 5 F r termostatens f ler ned i varmepatronens f lerr r Fa...

Page 24: ...6 Monter kabler til termo stat og til varmepatron i forskruningerne Forbind til koblingsbok sen F r yderkappen ud over beslagets top 7 Forbind kablet til varme patronen ved at 1 l sne de tre m trikke...

Page 25: ..._______ 24 8 Forbind jordforbindelsen fra koblingsboksens yderkapper og kablets jordforbindelse med ter mostatbeslaget hvis det valgte kabel er jordet 9 Forbind kablet til termo staten som vist 10 F r...

Page 26: ...________________________________________________________________________________________________ 25 11 Monter l g og drejeknap Produktet er klar til brug...

Page 27: ...a pressure tank must be made according to EN13445 and EN60364 Place the heater in the tank either horizontally or vertically plugged in from the bottom Never place the heater in the tank with the jun...

Page 28: ...of part 1 consists of a nut for the rear side and a top for the front 3 Remove the content from part 1 to make room for installation of end cap 4 Place the nut at the inner side of the pipe of part 1...

Page 29: ...____________________________________________________ 28 5 Mount the three screws in the inner part of part 1 6 Connect part 1 and part 2 as described below 7 The three screws of part 1 fit into part 2...

Page 30: ...90 mm of the insulation from the cable Mount 4 mm cable shoes at the earth cable Mount cable shoes at the phases 9 Remove the nut from the gland Put the cable through the nut and the gland 10 The hea...

Page 31: ...pipe while drawing the cable care fully through the gland 12 Lock the cable into posi tion by tightening the gland 13 Mount part 4 at the open end of part 1 Ensure that the holes of part 1 and part 4...

Page 32: ...____________________________ 31 Assembly guide EN Product Round junction box DR Item no 19004605 1 Mount the thermal fuse on the bracket by follow ing the procedure below 2 Compress the bracket enabli...

Page 33: ...________________________________________ 32 3 Mount the three short wires Connect the wires to the immersion heater by loosening the three nuts placing the wires and tightening the nuts again 4 Connec...

Page 34: ...sensor of the thermal fuse into the probe pipe of the heating element Tighten the three screws connecting both parts 6 Lead the wires into the positions 11 21 and 31 7 Mount the cable for the heating...

Page 35: ...y Conductor U 1 to posi tion 12 of the thermal fuse Conductor V 2 to posi tion 22 of the thermal fuse Conductor W 3 to posi tion 32 of the thermal fuse Connect the earth con nection of the cable with...

Page 36: ...________________________________________________________________________________________________ 35 10 Mount the cover The immersion heater is ready for use...

Page 37: ...______________________ 36 Assembly guide EN Product Round junction box ER Item no 19001080 19001114 19001122 1 Mount the thermostat at the bracket by following the procedure below 2 Compress the brack...

Page 38: ...________________ 37 3 Fasten the thermostat by means of the two screws 4 Mount the three short wires Connect the wires to the heating element by loos ening the three nuts placing the wires and tighten...

Page 39: ...__________________________________________________________ 38 6 Lead the sensor of the thermostat into the probe pipe of the heating ele ment Tighten the three screws connecting both parts 7 Lead the...

Page 40: ...____________ 39 8 Mount the cable for the heating element in the gland Lead the outer casing over the top of the bracket 9 Connect the earthing from the outer casing of the junction box and the earthi...

Page 41: ...r side of the junction box 11 Connect the three con ductors of the thermostat in this way Conductor U 1 to posi tion 12 of the thermostat Conductor V 2 to posi tion 22 of the thermostat Conductor W 3...

Page 42: ...________________________________________________________________________________________________ 41 13 Mount the cover and the rotary switch The immersion heater is ready for use...

Page 43: ..._______________________________ 42 Assembly guide EN Product Round junction box OR Item no 194600 1 Mount the thermal fuse on the bracket by follow ing the procedure below 2 Compress the bracket enabl...

Page 44: ...__________________________________________________________ 43 3 Fasten the thermal fuse by means of the brass nut 4 Fasten the unused sen sor thread to the side of the bracket 5 Connect the thermal fu...

Page 45: ..._________________________________ 44 6 Lead the sensor of the thermal fuse into the probe pipe of the heating element 7 Connect the earth con nection from the outer casing of the junction box with the...

Page 46: ...eating element through the other gland Connect the earth con nection of the cable to the thermal fuse bracket if the cable in question is grounded 10 Connect the cable to the heating element by 1 loos...

Page 47: ...ermal fuse backet with the immer sion heater by fastening the three screws of the thermal fuse bracket to the heating element 12 Lead the outer casing of the junction box to the bottom position Make s...

Page 48: ...______________________________________ 47 Assembly guide EN Product Round junction box MR Item no 19001006 19001015 19001031 1 Mount the thermostat on the bracket 2 Compress the bracket ena bling the...

Page 49: ..._________________________ 48 3 Fasten the thermostat by means of the two screws 4 Connect the thermostat and the heating element in this way 5 Lead the sensor of the ther mostat into the probe pipe of...

Page 50: ...d the outer casing over the top of the bracket 7 Connect the cable to the heating element by 1 loosening the three nuts without butt plates 2 placing the wires so that the heating element is star conn...

Page 51: ..._______________________________________________________ 50 9 Connect the cable to the thermostat as shown 10 Lead the outer casing of the junction box to the bottom position Make sure that the wires a...

Page 52: ...________________________________________________________________________________________________ 51 11 Mount cover and knob The item is ready for use...

Page 53: ...ation gem EN13445 und EN60364 auszuf hren Den Einschraubheizk rper im Beh lter waagrecht oder senkrecht vom Boden her einsetzen Der Einschraubheizk rper darf im Beh lter niemals so eingesetzt wer den...

Page 54: ...die R ckseite und einem Deckel f r die Vorderseite 3 Den Inhalt aus Teil 1 herausnehmen um Platz f r die Montage des End stopfens zu haben 4 Die Mutter auf der Innen seite des Rohrteils in Teil 1 plat...

Page 55: ...___________________________ 54 5 Die drei kleinen Schrau ben in den Innenteil von Teil 1 einsetzen 6 Teil 1 und Teil 2 wie nachstehend beschrie ben verbinden 7 Die drei kleinen Schrau ben in Teil 1 pa...

Page 56: ...inen 4 mm Kabelschuh am Erdungsleiter montie ren Kabelschuhe an den Phasen montieren 9 Die Mutter von der Ver schraubung abschrau ben Das Kabel durch die Mut ter und anschlie end durch die Verschraubu...

Page 57: ...itig vorsichtig das Kabel her ausziehen 12 Die Verschraubung um das Kabel fest anziehen damit das Kabel gesi chert ist 13 Teil 4 am offenen Ende von Teil 1 montieren Sicherstellen dass die L cher in T...

Page 58: ..._ 57 Installationsanleitung DE Produkt Runde Anschlussdose DR Artikelnummer 19004605 1 Die Thermosicherung gem nachstehender Vorgehensweise am Be schlag montieren 2 Den Beschlag zusam mendr cken sodas...

Page 59: ..._________________ 58 3 Die drei kurzen Leitungs st cke montieren Die Leitungsst cke am Heizelement befestigen hierzu die drei Muttern ohne Lasche l sen die Leitungsst cke aufste cken und die Muttern w...

Page 60: ...ng in das F hler rohr des Heizelements einf hren Die drei Schrauben fest ziehen die die beiden Teile verbinden 6 Die drei Leitungsst cke auf Position 11 21 und 31 aufstecken 7 Das Kabel zum Heizele me...

Page 61: ...Position 12 an der Thermosicherung aufstecken Ader V 2 an Position 22 an der Thermosicherung aufstecken Ader W 3 an Position 32 an der Thermosicherung aufstecken Die Erdungsverbindung des Kabels am B...

Page 62: ...________________________________________________________________________________________________ 61 10 Den Deckel montieren 11 Der Einschraubheizk r per ist einsatzbereit...

Page 63: ...______ 62 Installationsanleitung DE Produkt Runde Anschlussdose ER Artikelnummer 19001080 19001114 19001122 1 Den Thermostat gem nachstehender Vorge hensweise am Beschlag montieren 2 Den Beschlag zusa...

Page 64: ..._______ 63 3 Den Thermostat mit den beiden Schrauben befes tigen 4 Die drei kurzen Leitungs st cke montieren Die Leitungsst cke am Heizelement befestigen hierzu die drei Muttern l sen die Leitungsst c...

Page 65: ..._________________________________________________ 64 6 Den F hler des Thermos tats in das F hlerrohr des Heizelements einf hren Die drei Schrauben fest ziehen die die Teile ver binden 7 Die drei Leitu...

Page 66: ...as Kabel des Heizele ments an der zugeh ri gen Verschraubung mon tieren Die Au enkappe ber das Oberteil des Beschlags f hren 9 Die Erdungsverbindung von der Au enkappe der Anschlussdose und der Erdung...

Page 67: ...stecken und auf der anderen Seite der Anschlussdose heraus f hren 11 Die drei Adern des Ka bels am Thermostat be festigen Ader U 1 an Position 12 Ader V 2 an Position 22 Ader W 3 an Position 32 12 Die...

Page 68: ...________________________________________________________________________________________________ 67 13 Den Deckel und den Drehknopf montieren Der Einschraubheizk r per ist jetzt einsatzbereit...

Page 69: ...___________ 68 Installationsanleitung DE Produkt Runde Anschlussdose OR Artikelnummer 19004600 1 Die Thermosicherung gem nachstehender Vorgehensweise am Be schlag montieren 2 Den Beschlag zusam mendr...

Page 70: ...__________________________________ 69 3 Die Thermosicherung mithilfe der mitgelieferten Messingmutter befesti gen 4 Den unbenutzten F hler draht mit Kabelbindern an der Seite des Be schlags befestigen...

Page 71: ...________________ 70 6 Den F hler der Thermos icherung in das F hler rohr des Heizelements einf hren 7 Die Erdungsverbindung von der Au enkappe der Anschlussdose durch die Verschraubung mit dem Beschla...

Page 72: ...en soll durch die andere Verschraubung f hren Die Erdungsverbindung des Kabels am Beschlag der Thermosicherung befestigen wenn das gew hlte Kabel geerdet ist 10 Das Kabel mit dem Heiz element verbinde...

Page 73: ...icherung mit dem Heizelement verbinden dazu die drei Schrauben des Beschlags der Ther mosicherung am Heiz element festziehen 12 Die Au enkappe bis zum Anschlag auf die An schlussdose schieben und daf...

Page 74: ..._______________ 73 Installationsanleitung DE Produkt Runde Anschlussdose MR Artikelnummer 19001006 19001015 19001031 Vorgehensweise 1 Den Thermostat am Be schlag montieren 2 Den Beschlag zusam mendr c...

Page 75: ...______________________ 74 3 Den Thermostat mit den beiden Schrauben befes tigen 4 Den Thermostat wie folgt mit dem Heizelement verbinden 5 Den F hler des Thermos tats in das F hlerrohr des Heizelement...

Page 76: ...hrau bungen an Thermostat und Heizelement befesti gen Mit der Anschlussdose verbinden Die Au enkappe ber das Oberteil des Be schlags f hren 7 Das Kabel mit dem Heiz element verbinden dazu 4 die drei M...

Page 77: ...enkappe der Anschlussdose und der Erdungsverbindung des Kabels mit dem Beschlag des Thermostats verbin den wenn das gew hlte Kabel geerdet ist 9 Das Kabel wie gezeigt mit dem Thermostat ver binden 10...

Page 78: ...________________________________________________________________________________________________ 77 11 Deckel und Drehknopf montieren Das Produkt ist einsatz bereit...