Use this item to select an optimal setting for Super IO Device.
The optional settings: [IO=3F8h; IRQ=4;]; [IO=3F8h; IRQ=3,4,5,7,10,11;];
[IO=2F8h; IRQ=3,4,5,7,10,11;]; [IO=3E8h; IRQ=3,4,5,7,10,11;]; [IO=2E8h;
IRQ=3,4,5,7,10,11;].
Transmission Mode Select
The optional settings: [RS422]; [RS232]; [RS485].
Mode Speed Select
The optional settings: [RS232/RS422/RS485=250kbps]; [RS232=1Mbps,
RS422/RS485=10Mbps].
Serial Port FIFO Mode
The optional settings: [16-Byte FIFO]; [32-Byte FIFO]; [64-Byte FIFO]; [128-Byte
FIFO].
WatchDog Reset Timer
Use this item to enable or disable WDT reset function.
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Value
User can select a value in the range of [10] to [255] seconds when ‘WatchDog
Reset Timer Unit’ set as [Sec]; or in the range of [1] to [255] minutes when
‘WatchDog Reset Timer Unit’ set as [Min].
WatchDog Reset Timer Unit
The optional settings: [Sec.]; [Min.].
WatchDog Wake-up Timer in ERP
This item support WDT wake-up while ‘
ERP Support
’ is set as [Auto].
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Timer Value in ERP
User can select a value in the range of [10] to [4095] seconds when ‘
WatchDog