3-7-3 Onboard Super IO Function
CMOS Setup Utility – Copyright(C) 1984-2004 Award Software
Onboard Super IO Function
Item Help
Onboard FDD Controller Enabled
Onboard Serial Port 1 3F8/IRQ4
Onboard Parallel Port 378/IRQ7
Parallel Mode SPP
EPP Mode Select EPP1.9
ECP Mode Use DMA 3
Menu Level >>
↑↓→←
Move Enter:/-/PU/PD:Value F10:Save ESC:Exit F1:General Help
F5:Previous Values F6:Optimized Defaults F7:Standard Defaults
Onboard FDD Controller
Select Enabled if your system has a floppy disk controller (FDD) installed on the system board
and you wish to use it. If you install add-on FDC or the system has no floppy drive, select
Disabled in this field. The settings are: Enabled and Disabled.
Onboard Serial Port
Select an address and corresponding interrupt for the first and the second serial ports. The
settings are: 3F8/IRQ4, 3E8/IRQ4, Disabled, Auto.
Onboard Parallel Port
There is a built-in parallel port on the on-board Super I/O chipset that Provides Standard, ECP,
and EPP features. It has the following option:
Disabled
(3BCH/IRQ7)/
Line Printer port 0
(278H/IRQ5)/
Line Printer port 2
(378H/IRQ7)
Line Printer port 1
Parallel Port Mode
SPP
: Standard Parallel Port
EPP
: Enhanced Parallel Port
ECP
: Extended Capability Port
SPP/EPP/ECP/ECP+EPP
To operate the onboard parallel port as Standard Parallel Port only, choose “SPP.” To
operate the onboard parallel port in the EPP modes simultaneously, choose “EPP.” By
choosing “ECP”, the onboard parallel port will operate in ECP mode only. Choosing
“ECP+EPP” will allow the onboard parallel port to support both the ECP and EPP modes
simultaneously. The ECP mode has to use the DMA channel, so choose the onboard
parallel port with the ECP feature. After selecting it, the following message will appear:
“ECP Mode Use DMA” at this time, the user can choose between DMA channels 3 to 1.
The onboard parallel port is EPP Spec. compliant, so after the user chooses the onboard
parallel port with the EPP function, the following message will be displayed on the screen:
“EPP Mode Select.” At this time either EPP 1.7 spec. or EPP 1.9 spec. can be chosen.