Machine Shut Down Procedure
1. When high pressure cleaning or water jetting task is
complete, release high pressure trigger.
2. Return to the unit controls.
3. Idle down unit RPMs via throttle control (if applicable)
4. Proceed to power down the engine via kill switch or
key switch (if applicable). Refer to engine operator
manual.
5. Turn water supply OFF.
6. Release system back pressure by pressing the trigger
on the spray gun (if applicable).
7. Disconnect high and low pressure hoses and coil the
assembly for safety and proper storage.
Hose Reel Brake Adjustment
The reels are equipped with an adjustable brake to
prevent the hose from playing off the reel under its own
weight. Tightening wingnut increases the drag on the reel,
loosening decreases the drag. Adjust as desired. The brake
only works in one direction (to resist hose moving off reel)
(Figure 15).
Transportation and Storage
1. Turn off the fuel valve and the battery isolation switch.
2. Drain water from Jetter as needed.
3. Coil hoses and secure equipment appropriately. All
loose material must be removed. Transport remote reel
separate from jetter.
4. Jetter is equipped with wheels to allow transport over
smooth level surfaces.
5. Jetter weighs 195kg (approx.) Use appropriate
equipment and methods to load and transport. Use
all four points supplied at the top corners of the frame
when lifting or use the intergrated forklift pockets with
a forklift. Use rigging with current certifications per the
manufacturer’s instructions.
Figure.15 - Brake Adjustment
Maintenance Instructions
WARNING
Before performing any maintenance, engine switch
battery isolation switch should be in OFF position and
spark plug wires should be disconnected to prevent
inadvertent operation. Open water control valve to
release any fluid pressure in system.
Always wear safety glasses and gloves when
performing any maintenance to help protect against
drain chemicals and bacteria.
Cleaning
The hose should be cleaned as needed with hot, soapy
water and/or disinfectants. Do not allow water to enter the
engine or electrical system. Do not clean with pressure
washer. Wipe the unit down with a damp cloth.
Engine
Maintain the engine as directed in the engine operator’s
manual supplied with the unit. An hour meter is included on
the engine to monitor jetter use.
Battery
To change battery
1. Unclip strap holding battery box top on, remove top.
2. Disconnect ground (-) cable connection first, followed
by positive (+) cable connection.
3. Remove battery.
4. Reverse procedure to install.
Replacement batteries should have the following
specifications:
• BCI Group/Type: U1
• Size (L x W x H): 196 x 128 x 159 (mm)
• Voltage: 12
• Cold Cranking Amps (CCA): 350
• Reserve Capacity (RC): 45
• Terminal Type: Offset Lug Terminal (OLT)
• Assembly Type: C
• Max Charging Volt: 14.8
Pump Lubrication/Maintenance
Check the pump oil level prior to each use. Place the jetter
on a level surface. Wipe any dirt and debris from the area
of the dipstick and sight-glass. Oil level should be at the
middle of the sight-glass (Figure 16). If needed, remove the
dipstick and add SAE 15W-40 Mineral non-detergent oil,
fill to half-way on the sight-glass. Do not overfill, reinstall
dipstick.