Jetwave TYPHOON HOT G2 Manual Download Page 10

10

TYPHOON HOT G2 MANUAL -  WATER JETTER/DRAIN CLEANER

The manufacture reserves the right to modify design features and technical facts without notice: due to our principals of continuous improvement.

Applications

Pipe Size

Suggested Hose (ID)

Kitchen sinks, laundry tubs and stacks, clean-outs, and vents.

2” – 3”

1/8” Whip hose (optional equipment)

Shower and floor drains, lateral lines, and grease traps.

3” – 4”

1/8” or 3/16” Whip hose (optional 
equipment) or 1/4” Remote Reel

Sewer and storm water lines

4” – 6”

1/4” Remote Reel or 3/8” Primary Reel

Lateral and main lines.

6” – 10”

3/8” Primary Reel

Jetter Hose Selection Chart

Jetter Nozzle Selection Chart

Penetrating Nozzle (Red Cowl): Uses three jet thrusters in reverse plus one jet pointed 
forward to penetrate solid grease, sludge or sediment blockages. The forward jet blasts a 
small hole in the blockage for the nozzle to follow. It is also very effective when jetting ice 
blockages. Attaches to hose with quick connect, includes cowl protection. For 3” to 6” 
drain sizes.
Negotiator Nozzle (Blue Cowl): Use this nozzle to help negotiate more difficult bends or 
gully traps as it is of a short construction. This nozzle has three reverse jet thrusts and one 
forward. Attaches to hose with quick connect, includes cowl protection. For 3” to 6” drain 
sizes.
Large Drain Nozzle: hard fixed end within the standard kit for work on smaller diameter 
pipes (3” to 4”) with tighter radiuses/bends. This nozzle is smaller in size and eliminates 
the quick connect to allow easier negotiation around bends in the line. It has three rear jets 
with one facing forward for a range of applications. Nozzle includes a 1/4” BSPT thread to 
connect directly to hose thread.
Small Drain Nozzle: supplied with optional equipment flexible leader for smaller diameter 
pipes (2” to 4”). This nozzle is exceptionally small and short and has three rear jets with 
one facing forward for a range of more domestic applications e.g. internal drains/pipes 
etc. Nozzle includes a 1/8” BSPT thread to connect directly to hose thread as supplied 
standard.
Reverse Root Cutting Nozzle: Use to clear roots and other type of blockages. Uses a 
rear facing oscillating jet for more complete drain cleaning. Attaches to hose with quick 
connect. For drain sizes 4” to 10”, as noted here.

WARNING If using the Reverse Root Cutting nozzle for drains larger than 6”/150 mm and up to 
10”/250 mm, an extension must be used to reduce the risk of the nozzle changing direction in the 
drain, exiting at the user and causing serious injury.

If using nozzles that are not equipped with a quick connect, the female quick connect must be removed from the end of 
the hose and the nozzle securely threaded on. Stock hoses and nozzles use BSPT threads. Make sure that the threads 
match and that sealant is used to prevent leaks.

Summary of Contents for TYPHOON HOT G2

Page 1: ...T SERIAL NO ENGINE SERIAL NO PURCHASE DATE Hot Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents of this manual...

Page 2: ...re Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Drain Preparation 8 Hose Set Up 8 9 Jetter Hose Selection Chart 10 Jetter Nozzle Selection Chart 10 Operating Instructions 11 13...

Page 3: ...listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Keep bystanders children and visitors away while operati...

Page 4: ...l protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators head protection hearing...

Page 5: ...d to use a combination of water pressure heat and flow to clear grease sludge sediment and roots out of drains A highly flexible and lightweight hose is propelled through the drain pipe by the reverse...

Page 6: ...alf way on sight glasses per Maintenance section Wheels Optional Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the whee...

Page 7: ...and Work Area Set up Always wear safety glasses gloves and other appropriate protective equipment when setting up your jetter to protect against chemicals and bacteria on the equipment Rubber soled n...

Page 8: ...Do not use water hotter than 60 C this can cause pump and or float valve damage When using warm water use appropriate personal protective equipment to reduce the risk of burns When using in cold weath...

Page 9: ...but should be at least 4 1 2 m 4 Select a nozzle and attach Use nozzles specifically sized for the jetter being used Using incorrect nozzles can cause poor performance low operating pressure or low fl...

Page 10: ...Nozzle hard fixed end within the standard kit for work on smaller diameter pipes 3 to 4 with tighter radiuses bends This nozzle is smaller in size and eliminates the quick connect to allow easier neg...

Page 11: ...ays includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators and steel toed footwear Follow operating instr...

Page 12: ...the nozzle 6 Assume a proper operating position Be sure you can control the ON OFF action of a water control valve ball valve or foot valve Do not turn the valve ON yet In case of emergency you must b...

Page 13: ...etwave water jetting machine can also be used as a pressure washer Use as a pressure washer is similar to use as a jetter and those instructions should be used in conjunction with the following 1 Loca...

Page 14: ...klift pockets with a forklift Use rigging with current certifications per the manufacturer s instructions Figure 15 Brake Adjustment Maintenance Instructions WARNING Before performing any maintenance...

Page 15: ...here the temperature is near or below 0 C the jetter must be properly prepared If water freezes in the pump it can damage it After the tank is drained remove the hose from the water inlet filter Open...

Page 16: ...trapped in system Jetter nozzle orifices are blocked Remove nozzle and insert jet hose in drain line Run jetter to flush trapped air or debris Remove nozzle Use nozzle cleaning tool to clear nozzle o...

Page 17: ...R DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Hour Meter Reading Date Maintenance Perf...

Page 18: ...8 TYPHOON HOT G2 MANUAL WATER JETTER DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 19: ...9 TYPHOON HOT G2 MANUAL WATER JETTER DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 20: ...3599 sales jetwave com au jetwave com au jetwavegroup jetwave group Copyright Jetwave Group Pty Ltd All Rights Reserved Subject to change without notice The manufacture reserves the right to modify de...

Reviews: