background image

6

RAPTOR MANUAL -  HIGH PRESSURE CLEANER

The machine serial number is located on the frame. The 
first 4 digits indicate the year and month of manufacture 
respectively.

NOTICE This machine is made to high pressure water 
clean. If properly used it should not damage a surfaces that 
is in good condition and properly designed, constructed 
and maintained. If the surface is in poor condition or not 
properly designed, constructed or maintained, the water 
cleaning process may not be effective or could cause 
damage to the surface. The best way to determine the 
condition of a surface before cleaning is through visual 
inspection.
 
Improper use of this pressure cleaner can damage the unit 
and the surface. This machine may not clear all substrate 
debris.

Machine Assembly

WARNING

To prevent serious injury during use and prevent 
machine damage, follow these procedures for proper 
assembly.

Engine Oil

NOTICE The unit is shipped with oil in the engine.
Operating the engine with low or no oil will result in engine 
failure. See supplied engine operator’s manual for specific 
information on checking oil, adding oil and oil selection.

Pump

The unit is shipped with oil in the pump.
Check oil level (ensure half way on sight-glasses) per
Maintenance section. 

Wheels

Typically the unit is boxed and shipped without wheels 
assembled. Wheels, Axle & Locking Collar are found within 
the box. To assemble the wheels, slide axle through axle 
location hole, slide wheels on each side find centerline and 
proceed to install locking collar each side with 4mm Allen 
key tool.

Pre-Operation Inspection

WARNING

Before each use, inspect your pressure cleaner and 
correct any problems to reduce the risk of serious 
injury from high pressure water and other causes and 

prevent unit damage.
Always wear appropriate safety equipment, when 
inspecting your unit.

1.  Make sure that the engine switch is in the OFF position.  

2.  Clean any oil, grease or dirt from the equipment, 

including the handles and controls. This aids inspection 
and helps prevent the machine or control from slipping 
from your grip. 

3.  Inspect the high pressure cleaner and accessories for 

the following:

•  Proper assembly and completeness.
•  Broken, worn, missing, misaligned, binding or loose 

parts.

•  Presence and readability of the warning labels.  

(See Figure 4.)

•  Any other condition which may prevent the safe 

and normal operation.

If any problems are found, do not use the unit until the 
problems are corrected.

Figure.4 - Raptor Warning Labels

Clean water filter (Figure 5). Unscrew the brass nut from 
the filter and remove and clean the mesh filter. Dirt and 
debris can restrict the water flow to the pump and cause 
performance issues. 

Summary of Contents for Raptor

Page 1: ...r which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury READ CAREFULLY ENGLISH VERSION ...

Page 2: ...nt Description Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportation and Storage Maintenance Instructions Cleaning Engine Battery Pump Lubrication Maintenance Preparing Pump for Cold Weather Storage Optional Equipment Machine Storage Service And Repair Disposal...

Page 3: ... shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating a power to...

Page 4: ... goggles protective clothing respirators head protection hearing protection and steel toed footwear Practice good hygiene Use hot soapy water to wash hands and other body parts exposed to drain contents after handling or using drain cleaning equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contamination with toxic or infectious mater...

Page 5: ...ssure Cleaner Machine is a portable unit designed to use a combination of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such high pressure to remove dirt and grime from surfaces The Raptor High Pressure Cleaner is equipped with an gasoline Honda engine to ...

Page 6: ...Maintenance section Wheels Typically the unit is boxed and shipped without wheels assembled Wheels Axle Locking Collar are found within the box To assemble the wheels slide axle through axle location hole slide wheels on each side find centerline and proceed to install locking collar each side with 4mm Allen key tool Pre Operation Inspection WARNING Before each use inspect your pressure cleaner an...

Page 7: ...a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operate outside Set up the unit and work area according to these procedures to reduce the risk of injury from high pressure water chemical burns infections carbon monoxide and other causes and prevent jetter damage 1 Ch...

Page 8: ...putation do not direct spray at people or animals do not operate jetter above pressure rating or 60 C inlet water temperature This increases the risk of injury including burns and damage to the unit One person must control the unit process and water flow Always use appropriate personal protective equipment while handling and using high pressure cleaning equipment Appropriate personal protective eq...

Page 9: ...e orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive wear are evident Activate trigger and run the unit to remove air or debris from the system Turn the unit OFF before removing or attaching the lance nozzle 6 Assume a proper operating position Be sure you can control the ON OFF action of a water control valve Do not turn the valve ON yet In...

Page 10: ...al system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To change battery if applicable 1 Unclip strap if applicable holding battery box top on remove top 2 Disconnect ground cable connection first followed by positive cable connection 3 Remove battery 4 Reverse procedure ...

Page 11: ...ked area that is out of reach of children and people unfamiliar with High Pressure Cleaners This machine can cause serious injury in the hands of untrained users See Maintenance section for information on cold weather storage See engine operator s manual for specific information on engine storage Service And Repair WARNING Improper service or repair can make machine unsafe to operate The Maintenan...

Page 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil seal worn Water entering through breather Check and change oil twice as often Check and replace Water dripping from pump Piston packing worn Piston guide o rings worn Check and replace Check and replace ...

Page 13: ...13 RAPTOR MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log ...

Page 14: ...14 RAPTOR MANUAL HIGH PRESSURE CLEANER Notes ...