background image

10

RAPTOR MANUAL -  HIGH PRESSURE CLEANER

Transportation and Storage

1.  Turn OFF the fuel valve.
2.  Drain water from unit as needed.
3.  Coil hoses and secure equipment appropriately. All 

loose material must be removed. Transport remote reel 
separate from unit.

4.  Unit is equipped with wheels to allow transport over 

smooth level surfaces.

5.  Unit weighs from 50-80kg (approx.) Use appropriate 

equipment and methods to load and transport. 

Maintenance Instructions

WARNING

Before performing any maintenance, engine switch 
battery isolation switch should be in OFF position and 
spark plug wires should be disconnected to prevent 
inadvertent operation. Open water control valve to 
release any fluid pressure in system.
Always wear safety glasses and gloves when 
performing any maintenance to help protect against 
drain chemicals and bacteria.

Cleaning

The hose should be cleaned as needed with hot, soapy 
water and/or disinfectants. Do not allow water to enter the 
engine or electrical system. Do not clean with pressure 
washer. Wipe the unit down with a damp cloth. 

Engine

Maintain the engine as directed in the engine 
operator’s manual

 supplied with the unit. 

Battery

To change battery (if applicable)
1.  Unclip strap (if applicable) holding battery box top on, 

remove top.

2.  Disconnect ground (-) cable connection first, followed 

by positive (+) cable connection.

3.  Remove battery.
4.  Reverse procedure to install.
Replacement batteries should have the following  
specifications:
•  BCI Group/Type: U1
•  Size (L x W x H): 196 x 128 x 159 (mm)
•  Voltage: 12
•  Cold Cranking Amps (CCA): 350

•  Reserve Capacity (RC): 45
•  Terminal Type: Offset Lug Terminal (OLT)
•  Assembly Type: C
•  Max Charging Volt: 14.8

Pump Lubrication/Maintenance

Check the pump oil level prior to each use. Place the unit 
on a level surface. Wipe any dirt and debris from the area 
of the dipstick and sight-glass. Oil level should be at the 
middle of the sight-glass (Figure 16). If needed, remove the 
dipstick and add SAE 15W-40 Mineral non-detergent oil, 
fill to half-way on the sight-glass. Do not overfill, reinstall 
dipstick.

PUMP OIL SIGHT GLASS

Figure.16 - Checking Pump Oil Level

PUMP OIL DIPSTICK

Figure.16A - Checking Pump Oil Level

Summary of Contents for Raptor

Page 1: ...r which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury READ CAREFULLY ENGLISH VERSION ...

Page 2: ...nt Description Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportation and Storage Maintenance Instructions Cleaning Engine Battery Pump Lubrication Maintenance Preparing Pump for Cold Weather Storage Optional Equipment Machine Storage Service And Repair Disposal...

Page 3: ... shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating a power to...

Page 4: ... goggles protective clothing respirators head protection hearing protection and steel toed footwear Practice good hygiene Use hot soapy water to wash hands and other body parts exposed to drain contents after handling or using drain cleaning equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contamination with toxic or infectious mater...

Page 5: ...ssure Cleaner Machine is a portable unit designed to use a combination of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such high pressure to remove dirt and grime from surfaces The Raptor High Pressure Cleaner is equipped with an gasoline Honda engine to ...

Page 6: ...Maintenance section Wheels Typically the unit is boxed and shipped without wheels assembled Wheels Axle Locking Collar are found within the box To assemble the wheels slide axle through axle location hole slide wheels on each side find centerline and proceed to install locking collar each side with 4mm Allen key tool Pre Operation Inspection WARNING Before each use inspect your pressure cleaner an...

Page 7: ...a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows are open Only operate outside Set up the unit and work area according to these procedures to reduce the risk of injury from high pressure water chemical burns infections carbon monoxide and other causes and prevent jetter damage 1 Ch...

Page 8: ...putation do not direct spray at people or animals do not operate jetter above pressure rating or 60 C inlet water temperature This increases the risk of injury including burns and damage to the unit One person must control the unit process and water flow Always use appropriate personal protective equipment while handling and using high pressure cleaning equipment Appropriate personal protective eq...

Page 9: ...e orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive wear are evident Activate trigger and run the unit to remove air or debris from the system Turn the unit OFF before removing or attaching the lance nozzle 6 Assume a proper operating position Be sure you can control the ON OFF action of a water control valve Do not turn the valve ON yet In...

Page 10: ...al system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To change battery if applicable 1 Unclip strap if applicable holding battery box top on remove top 2 Disconnect ground cable connection first followed by positive cable connection 3 Remove battery 4 Reverse procedure ...

Page 11: ...ked area that is out of reach of children and people unfamiliar with High Pressure Cleaners This machine can cause serious injury in the hands of untrained users See Maintenance section for information on cold weather storage See engine operator s manual for specific information on engine storage Service And Repair WARNING Improper service or repair can make machine unsafe to operate The Maintenan...

Page 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil seal worn Water entering through breather Check and change oil twice as often Check and replace Water dripping from pump Piston packing worn Piston guide o rings worn Check and replace Check and replace ...

Page 13: ...13 RAPTOR MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log ...

Page 14: ...14 RAPTOR MANUAL HIGH PRESSURE CLEANER Notes ...

Page 15: ......

Page 16: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group ...

Reviews: