10
RAPTOR MANUAL - HIGH PRESSURE CLEANER
Transportation and Storage
1. Turn OFF the fuel valve.
2. Drain water from unit as needed.
3. Coil hoses and secure equipment appropriately. All
loose material must be removed. Transport remote reel
separate from unit.
4. Unit is equipped with wheels to allow transport over
smooth level surfaces.
5. Unit weighs from 50-80kg (approx.) Use appropriate
equipment and methods to load and transport.
Maintenance Instructions
WARNING
Before performing any maintenance, engine switch
battery isolation switch should be in OFF position and
spark plug wires should be disconnected to prevent
inadvertent operation. Open water control valve to
release any fluid pressure in system.
Always wear safety glasses and gloves when
performing any maintenance to help protect against
drain chemicals and bacteria.
Cleaning
The hose should be cleaned as needed with hot, soapy
water and/or disinfectants. Do not allow water to enter the
engine or electrical system. Do not clean with pressure
washer. Wipe the unit down with a damp cloth.
Engine
Maintain the engine as directed in the engine
operator’s manual
supplied with the unit.
Battery
To change battery (if applicable)
1. Unclip strap (if applicable) holding battery box top on,
remove top.
2. Disconnect ground (-) cable connection first, followed
by positive (+) cable connection.
3. Remove battery.
4. Reverse procedure to install.
Replacement batteries should have the following
specifications:
• BCI Group/Type: U1
• Size (L x W x H): 196 x 128 x 159 (mm)
• Voltage: 12
• Cold Cranking Amps (CCA): 350
• Reserve Capacity (RC): 45
• Terminal Type: Offset Lug Terminal (OLT)
• Assembly Type: C
• Max Charging Volt: 14.8
Pump Lubrication/Maintenance
Check the pump oil level prior to each use. Place the unit
on a level surface. Wipe any dirt and debris from the area
of the dipstick and sight-glass. Oil level should be at the
middle of the sight-glass (Figure 16). If needed, remove the
dipstick and add SAE 15W-40 Mineral non-detergent oil,
fill to half-way on the sight-glass. Do not overfill, reinstall
dipstick.
PUMP OIL SIGHT GLASS
Figure.16 - Checking Pump Oil Level
PUMP OIL DIPSTICK
Figure.16A - Checking Pump Oil Level