Water Supply

Run a hose from the water source to the unit water inlet.
Use the largest diameter, shortest length hose possible. A 
3/4” I.D. Inlet hose is the minimum recommended size. An 
appropriate backflow prevention device should be used to 
comply with all local codes and ordinances.
Dirt and debris in the water supply can cause excess pump 
wear, clog the unit filter, nozzles and reduce performance.
Do not use water from ponds, lakes or other sources that 
may be contaminated.
Fill the water tank prior to starting the unit (If Applicable).
The tank is equipped with a: (If Applicable)
•  Low water level shut-off (If Applicable) to prevent 

pump damage from insufficient water. This will shut 
OFF the engine when the tank water level falls below a 
predetermined level.

•  Float valve to shut-off inlet water when the tank is full, 

preventing water spillage through the tank vent. 

By removing two screws, the top of the tank can be 
removed for inspection or tank cleaning.

Warm water can be used for improved cleaning. Do not 
use water hotter than 60°C. When using warm water, use 
appropriate personal protective equipment to reduce the 
risk of burns.
When using in cold weather, use precautions to prevent 
water from freezing in the pump. This can damage the 
pump.

Hose Set-Up

Use care when routing hoses. Routing hoses over rough 
surfaces, sharp edges, crossing hoses, etc. can damage 
the hose jacket. Keeping the unit hose on the reel(s) will 
help to minimize hose damage.

Operating Instructions

CAUTION

Always wear eye protection to protect your eyes 
against dirt and other foreign objects. Always wear 
appropriate personal protective equipment for the 
work environment.
Never operate the unit without the hose attached to 
a spray gun. Hose can whip, causing striking injuries 
and spray can penetrate skin and cause serious 
injury.
High pressure fluid can inject under skin resulting 
in serious injury, including amputation. do not direct 
spray at people or animals. do not operate unit above 
pressure rating or 60°C (inlet water temperature). 
This increases the risk of injury, including burns, and 
damage to the unit. One person must control the unit 
process and water flow. 
Always use appropriate personal protective 
equipment while handling and using high pressure 
cleaning equipment. Appropriate personal protective 
equipment always includes safety glasses and 
gloves, and may also include equipment such as latex 
or rubber gloves, face shields, goggles, protective 
clothing, respirators, and steel toed footwear.
Follow operating instructions to reduce the risk of 
injury from whipping hoses, high pressure liquid 
injection, carbon monoxide and other causes.

1.  Make sure that machine and work area is properly set 

up and that the work area is free of bystanders and 
other distractions. If the unit is located remotely from 
the point of use, another person may be located at the 
unit.

2.  Attach the gun to the high pressure hose via coupling 

system.

3.  Attach the hose to the high pressure pump/valve 

outlet.

4.  Turn the battery isolator switch ON (If Applicable) and 

confirm the Emergency stop (If Applicable) button is in 
the out position (rotate button clockwise). 

5.  Confirm that the water supply is attached and turned 

on to low pressure pump inlet. Never start the engine 
without the water supply turned ON. This can damage 
the pump.

6.  Wash Wand Lock Out – the wash wand includes a lock 

out on the back of the trigger. Flip the lock out down 
to prevent the operation of the trigger when the wash 
wand is not in use.

Summary of Contents for Hornet G2 Series

Page 1: ...ct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol or Diesel Driven WARNING Read this Operator s Manual carefully before using this machine...

Page 2: ...Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Gearbox Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportatio...

Page 3: ...shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive a...

Page 4: ...personal protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators head protection...

Page 5: ...of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such h...

Page 6: ...heels Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on e...

Page 7: ...ngines produce carbon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows ar...

Page 8: ...ipment for the work environment Never operate the unit without the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High press...

Page 9: ...here is adequate water flow to the unit Turn the unit OFF Remove the nozzle and clean the orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive we...

Page 10: ...ne or electrical system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To...

Page 11: ...in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the sys...

Page 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil sea...

Page 13: ...13 HORNET G2 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 14: ...14 HORNET G2 MANUAL HIGH PRESSURE CLEANER Notes...