background image

10

HORNET G2 MANUAL -  HIGH PRESSURE CLEANER

Transportation and Storage

1.  Turn off the fuel valve and the battery isolation switch.
2.  Drain water from unit as needed.
3.  Coil hoses and secure equipment appropriately. All 

loose material must be removed. Transport remote reel 
separate from unit.

4.  Unit is equipped with wheels to allow transport over 

smooth level surfaces.

5.  Unit weighs 80kg (approx.) Use appropriate equipment 

and methods to load and transport. 

Maintenance Instructions

WARNING

Before performing any maintenance, engine switch 
battery isolation switch should be in OFF position and 
spark plug wires should be disconnected to prevent 
inadvertent operation. Open water control valve to 
release any fluid pressure in system.
Always wear safety glasses and gloves when 
performing any maintenance to help protect against 
drain chemicals and bacteria.

Cleaning

The hose should be cleaned as needed with hot, soapy 
water and/or disinfectants. Do not allow water to enter the 
engine or electrical system. Do not clean with pressure 
washer. Wipe the unit down with a damp cloth. 

Engine

Maintain the engine as directed in the engine 
operator’s manual

 supplied with the unit. 

Battery

To change battery (if applicable)
1.  Unclip strap (if applicable) holding battery box top on, 

remove top.

2.  Disconnect ground (-) cable connection first, followed 

by positive (+) cable connection.

3.  Remove battery.
4.  Reverse procedure to install.
Replacement batteries should have the following  
specifications:
•  BCI Group/Type: U1
•  Size (L x W x H): 196 x 128 x 159 (mm)
•  Voltage: 12
•  Cold Cranking Amps (CCA): 350

•  Reserve Capacity (RC): 45
•  Terminal Type: Offset Lug Terminal (OLT)
•  Assembly Type: C
•  Max Charging Volt: 14.8

Pump Lubrication/Maintenance

Check the pump oil level prior to each use. Place the unit 
on a level surface. Wipe any dirt and debris from the area 
of the dipstick and sight-glass. Oil level should be at the 
middle of the sight-glass (Figure 16). If needed, remove the 
dipstick and add SAE 15W-40 Mineral non-detergent oil, 
fill to half-way on the sight-glass. Do not overfill, reinstall 
dipstick.

PUMP OIL SIGHT GLASS

Figure.16 - Checking Pump and Gearbox Oil Level

PUMP OIL DIPSTICK

GEARBOX OIL DIPSTICK

Summary of Contents for Hornet G2 Series

Page 1: ...ct serial number which is located on nameplate UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Cold Water Petrol or Diesel Driven WARNING Read this Operator s Manual carefully before using this machine...

Page 2: ...Specifications Standard Equipment Machine Assembly Operation Engine Oil Pump Gearbox Oil Wheels Pre Operation Inspection Machine and Work Area Set Up Water Supply Operating Instructions Transportatio...

Page 3: ...shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Cluttered benches and dark areas invite accidents Do not operate power tools in explosive a...

Page 4: ...personal protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators head protection...

Page 5: ...of water pressure and flow to clean different surfaces from dirt grease grime Water is pumped through the high pressure plunger pump at increased pressure and flow allowing water to be used at such h...

Page 6: ...heels Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on e...

Page 7: ...ngines produce carbon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and run engine in an enclosed area even if doors and windows ar...

Page 8: ...ipment for the work environment Never operate the unit without the hose attached to a spray gun Hose can whip causing striking injuries and spray can penetrate skin and cause serious injury High press...

Page 9: ...here is adequate water flow to the unit Turn the unit OFF Remove the nozzle and clean the orifices with the nozzle cleaning tool Ensure correct nozzle orifice size is used and no signs of excessive we...

Page 10: ...ne or electrical system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the engine as directed in the engine operator s manual supplied with the unit Battery To...

Page 11: ...in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the sys...

Page 12: ...ton packing Dirty filter Check clean or replace Check that all hoses and fittings are airtight Check and replace Check and clean Presence of water in oil High humidity in air Piston packing or oil sea...

Page 13: ...13 HORNET G2 MANUAL HIGH PRESSURE CLEANER Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log...

Page 14: ...14 HORNET G2 MANUAL HIGH PRESSURE CLEANER Notes...

Page 15: ......

Page 16: ...jetwavegroup jetwave group jetwavegroup 72 74 Richmond Road Keswick 5035 Adelaide South Australia AU 61 8 8371 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group...

Reviews: