Jetwave EXPLORER G2 Manual Download Page 6

6

EXPLORER G2 MANUAL -  HIGH PRESSURE CLEANER

The manufacture reserves the right to modify design features and technical facts without notice: due to our principals of continuous improvement.

Figure.4B - Explorer G2 Water Filter

The machine serial number is located on the frame. The 
first letter & digits indicate the year and month of the 
manufacture. (G = 2021 (Year), 4 = April (Month)).

NOTICE This machine is made high pressure water clean. 
If properly used it should not damage a surfaces that is 
in good condition and properly designed, constructed 
and maintained. If the surface is in poor condition or not 
properly designed, constructed or maintained, the water 
cleaning process may not be effective or could cause 
damage to the surface. The best way to determine the 
condition of a surface before cleaning is through visual 
inspection. Improper use of this pressure cleaner can 
damage the unit and the surface. This machine may not 
clear all substrate debris.

Machine Assembly

WARNING

To prevent serious injury during use and prevent 
machine damage, follow these procedures for proper 
assembly.

Engine Oil

NOTICE The unit is shipped with oil in the engine.
Operating the engine with low or no oil will result in engine 
failure. See supplied engine operator’s manual for specific 
information on checking oil, adding oil and oil selection.

Pump/Gearbox Oil

The unit is shipped with oil in the pump and gearbox.
Check oil level (ensure half way on sight-glasses) per
Maintenance section. 

Wheels (Optional)

Typically the unit is boxed and shipped with wheels 
assembled. Wheels, Axles & Locking Collar are found 
within the box. To assemble the wheels, slide axles through 
axle location hole, slide wheels on each side find centerline 
and proceed to install locking collar each side with 4mm 
Allen key tool. (if applicable)

Pre-Operation Inspection

WARNING

Before each use, inspect your pressure cleaner and 
correct any problems to reduce the risk of serious 
injury from high pressure water and other causes and 
prevent unit damage. Always wear appropriate safety 
equipment, when inspecting your unit.

1.  Make sure that the battery isolator (if applicable) and 

engine switch is in the OFF position.  

2.  Clean any oil, grease or dirt from the equipment, 

including the handles and controls. This aids inspection 
and helps prevent the machine or control from slipping 
from your grip. 

3.  Inspect the high pressure cleaner and accessories for 

the following:

•  Proper assembly and completeness.
•  Broken, worn, missing, misaligned, binding or loose 

parts.

•  Presence and readability of the warning labels.  

(See Figure 4A.)

•  Any other condition which may prevent the safe 

and normal operation.

If any problems are found, do not use the unit until the 
problems are corrected.

Figure.4A - Explorer G2 Warning Labels

Clean water filter (Figure 4B). Unscrew the clear plastic 
bowl cover anti-clockwise and remove and clean the mesh 
filter (note: ensure the o-ring is set back into place before 
screwing plastic bowl back on). Dirt and debris can restrict 
the water flow to the pump and cause performance issues. 

Summary of Contents for EXPLORER G2

Page 1: ...te UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Hot Water Petrol or Diesel Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents...

Page 2: ...on 5 Specifications 5 Standard Equipment 5 Machine Assembly Operation 6 Engine Oil 6 Pump Gearbox Oil 6 Wheels 6 Pre Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Hose Setup 8 O...

Page 3: ...AVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Keep bystanders children and visitors away while operating a pressure cleaner Distractions can cause you to lose control Perso...

Page 4: ...ody parts exposed to drain contents after handling or using drain cleaning equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contaminati...

Page 5: ...o use a combination of water pressure heat and flow to clean different surfaces from dirt grease oil grime Water is pumped through the high pressure plunger pump boiler at increased pressure and flow...

Page 6: ...half way on sight glasses per Maintenance section Wheels Optional Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wh...

Page 7: ...the engine operator s manual Machine and Work Area Set up Always wear safety glasses gloves and other appropriate protective equipment when setting up your pressure cleaner Rubber soled non slip shoes...

Page 8: ...Keeping the unit hose on the reel s will help to minimize hose damage Operating Instructions CAUTION Always wear eye protection to protect your eyes against dirt and other foreign objects Always wear...

Page 9: ...re evident Activate trigger and run the unit to remove air or debris from the system Turn the unit OFF before removing or attaching the lance nozzle Assume a proper operating position Be sure you can...

Page 10: ...needed with hot soapy water and or disinfectants Do not allow water to enter the engine or electrical system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the...

Page 11: ...is near or below 0 C the unit must be properly prepared If water freezes in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valv...

Page 12: ...ly Earth leakage overload Check plug cable and switch Check earth leakage Will not product hot water Burner switch in off position Burner switch on but pump switch off Inadequate fuel supply Plugged f...

Page 13: ...URE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Hour Meter Reading Date Maintenance Performe...

Page 14: ...14 EXPLORER G2 MANUAL HIGH PRESSURE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 15: ...15 EXPLORER G2 MANUAL HIGH PRESSURE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 16: ...Reserved Subject to change without notice The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement 10 Smith Stre...

Reviews: