The manufacture reserves the right to modify design features and technical facts without notice: due to our principals of continuous improvement.

Change oil in pump after first 50 hours of operation and 
every 250 hours of operation after that. With the pump 
warm from operation, remove plug on bottom of pump 
and drain oil into suitable container. Replace plug. Fill to 
approximately half-way on the sight-glass with SAE 15W-
40 Mineral non-detergent oil using the checking procedure. 
Approximately 1000 ml of oil are required to change the 
pump oil.
At 1000 hours of use (less in severe use conditions) the unit 
should be taken to a Jetwave Independent Service Center 
for pump seal and valve service.

Gearbox Lubrication

Check the gearbox oil level prior to each use. Place the unit 
on a level surface. Wipe any dirt and debris from the area 
of the dipstick and sight-glass (Figure 16). Oil level should 
be at the middle of the sight-glass. If needed, remove the 
dipstick and add SAE 85W-140 gear lubricant oil, fill to 
half-way on the sight-glass. Do not overfill, reinstall dipstick.
Change oil in gearbox every 500 hours of operation. With 
the gearbox warm from operation, remove plug on bottom 
of gearbox and drain oil into suitable container. Replace 
plug. Fill to half-way on the sight-glass with SAE 85W-140 
gear lubricant oil. Approximately 300 ml of oil are required 
to change the gearbox oil.

Preparing Pump for Cold Weather Storage

If the unit will be stored under conditions where the 
temperature is near or below 0°C, the unit must be properly 
prepared. If water freezes in the pump, it can damage it.
After the tank is drained (if applicable), remove the hose 
from the water inlet filter. Open all valves in the system and 
use compressed air to force any water out of the system. 
This can also be used to remove water from the hoses.

Machine Storage

Store the unit in a well ventilated area protected from the 
weather elements. Keep the machine in a locked area 
that is out of reach of children and people unfamiliar with 
High Pressure Cleaners. This machine can cause serious 
injury in the hands of untrained users. See Maintenance 
section for information on cold weather storage. See 
engine operator’s manual for specific information on engine 
storage.

Service And Repair

WARNING

Improper service or repair can make machine unsafe 
to operate.

The “Maintenance Instructions” will take care of most 
of the service needs of this machine. Any problems not 
addressed by this section should only be handled by an 
authorized Jetwave service technician.
Unit should be taken to a Jetwave Independent Service 
Center or returned to the factory.
For information on your nearest Jetwave Independent 
Service Center or any service or repair questions:
•  Contact your local Jetwave distributor.
•  Visit jetwavegroup.com.au/find-a-dealer/ to find your 

local Jetwave contact point.

•  Contact Jetwave Technical Service Department at 

[email protected] or call (08) 8371 3599

Disposal

Parts of the unit contain valuable materials and can be 
recycled. There are companies that specialize in recycling 
that may be found locally. Dispose of the components in 
compliance with all applicable regulations. Contact your 
local waste management authority for more information.

Summary of Contents for EXPLORER G2

Page 1: ...te UNIT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Hot Water Petrol or Diesel Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents...

Page 2: ...on 5 Specifications 5 Standard Equipment 5 Machine Assembly Operation 6 Engine Oil 6 Pump Gearbox Oil 6 Wheels 6 Pre Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Hose Setup 8 O...

Page 3: ...AVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Keep bystanders children and visitors away while operating a pressure cleaner Distractions can cause you to lose control Perso...

Page 4: ...ody parts exposed to drain contents after handling or using drain cleaning equipment Do not eat or smoke while operating or handling high pressure cleaning equipment This will help prevent contaminati...

Page 5: ...o use a combination of water pressure heat and flow to clean different surfaces from dirt grease oil grime Water is pumped through the high pressure plunger pump boiler at increased pressure and flow...

Page 6: ...half way on sight glasses per Maintenance section Wheels Optional Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wh...

Page 7: ...the engine operator s manual Machine and Work Area Set up Always wear safety glasses gloves and other appropriate protective equipment when setting up your pressure cleaner Rubber soled non slip shoes...

Page 8: ...Keeping the unit hose on the reel s will help to minimize hose damage Operating Instructions CAUTION Always wear eye protection to protect your eyes against dirt and other foreign objects Always wear...

Page 9: ...re evident Activate trigger and run the unit to remove air or debris from the system Turn the unit OFF before removing or attaching the lance nozzle Assume a proper operating position Be sure you can...

Page 10: ...needed with hot soapy water and or disinfectants Do not allow water to enter the engine or electrical system Do not clean with pressure washer Wipe the unit down with a damp cloth Engine Maintain the...

Page 11: ...is near or below 0 C the unit must be properly prepared If water freezes in the pump it can damage it After the tank is drained if applicable remove the hose from the water inlet filter Open all valv...

Page 12: ...ly Earth leakage overload Check plug cable and switch Check earth leakage Will not product hot water Burner switch in off position Burner switch on but pump switch off Inadequate fuel supply Plugged f...

Page 13: ...URE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Hour Meter Reading Date Maintenance Performe...

Page 14: ...14 EXPLORER G2 MANUAL HIGH PRESSURE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 15: ...15 EXPLORER G2 MANUAL HIGH PRESSURE CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes...

Page 16: ...Reserved Subject to change without notice The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement 10 Smith Stre...

Reviews: