8
0 0 1 0 0 0
9
0 0 1 0 0 1
10
0 0 1 0 1 0
11
0 0 1 0 1 1
12
0 0 1 1 0 0
13
0 0 1 1 0 1
14
0 0 1 1 1 0
15
0 0 1 1 1 1
16
0 1 0 0 0 0
17
0 1 0 0 0 1
.
. . . . . .
63
1 11 1 1 1 1
6.2 Protocol setting
Protocol setting is done via a 4-position dip-switch SK2.
Switch
Item
1 2 3 4
Protocol Baud
Rate
1
Pelco-P 4800
2
Pelco-D 2400
6.3 Baud Rate setting
Baud rate setting is also done via Switch 1 and 2 of SK1.
Switch 1,2
Baud
Switch 1,2
Baud
6
9600
6
2400
6
4800
6
1200
Note: dip-switch up is “on”
For example, if you need 2400 baud, Switch 1 is “off” and 2 is “on”.