9
A. Determine fiber size
• Determine fiber size to be installed.
B. Select cable seal
• Choose the correct cable seal matching the cable size.
C. Install cable seal and fiber in track
• Install the appropriate cable seal on the cable. Once the cable seal is positioned properly on the fiber
you can install the fiber cable in the wheel drive, see E.
D. Install duct
• Ensure there is adequate length of duct available to avoid unnecessary strain on the duct.
• Place fibre cable into duct, place fibre cable and seal into the duct clamp.
• Once the duct is in place, secure the configuration by closing the top half of the duct clamp and
pressing firmly together. Close duct clamp cover and hand tighten the knob to secure.
E. Install fiber cable in the wheel drive and tighten
• Feed the cable in the wheel drive.
• Tighten adjustable clamp force wheel using the screw knob to ensure even pressure on the fibre cable.
Do not over tighten!
F. Adjust clutch for fibre security
• Adjust if needed, tighten it by turning the knob right and loosing it by turning left.
G. Connect battery to blowing unit
H. Connect air compressor
NOTE: Ensure the air control valve is off before connecting the air hose.
• Attach the air compressor hose to the air compressor if necessary.
• Then connect the compressor hose to the blower unit. The unit uses a standard quick connect air
compressor coupling (always use water separator on the compressor).
To avoid creating a trip hazard always route
air hose out of the way and secured to a stable object.
The fiber pan/reel should be placed axially perpendicular to the length of micro duct and typically 6ft
(2 m) or more from the TriggAIR. The TriggAIR must be positioned in-line between the fiber to be installed
and the micro duct. The fiber should not enter the TriggAIR at an angle of more than 10 degrees from
the intended axis.