2. Technical information
A. Condition of use
1.
Temperature from -15° C to +40° C
2.
Humidity from 20 % to 90 %
3.
Weather conditions relevant to working conditions
4.
Natural and/or artificial lighting of the work site, >200 lux
B. Air compressor requirements
1.
Pneumatic pressure
16 bar maximum
2.
Required air flow
0,1-0,3 m3/min
3.
Air hose fittings
Cejn type
C. Operational capacities
1.
Max pushing force
30N
2.
Pushing speed
Adjustable 0-150 m/min
3.
Fiber sizes
0,5 mm to 3,0 mm
4.
Duct sizes
5,0 and 7,0 mm
D. Electrical requirements
1.
Power requirements
Volt max 12 V, 4,0 Ah
2.
Power connection
Milwaukee standard
E. Physical specifications
1. Height
260
mm
2.
Length
200
mm
3.
Width
120
mm
4.
Weight 2,3
kg
F. Wheel drive specifications
1.
Adjustable clamp force
G. Pipecoupling requirements
1.
Must withstand maximum air pressure of 16 bar
2.
Must withstand axial loading and vibration
3.
Must be a compression type coupler
4.
Must fit snugly
5.
Duct ends must be cut off squarely and deburred
6.
Duct must be fully seated into the connector
6