Register areas

Description

Visualization

365100

Language selection according to ID

8.15 Flag

32 combined flags

203100

0 ... 31

203104

128 ... 159

203101

32 ... 63

203105

160 ... 191

203102

64 ... 95

203106

192 ... 223

203103

96 ... 127

203107

224 ... 255

16 combined flags

203108

0 ... 15

203116

128 ... 143

203109

16 ... 31

203117

144 ... 159

203110

32 ... 47

203118

160 ... 175

203111

48 ... 63

203119

176 ... 191

203112

64 ... 79

203120

192 ... 207

203113

80 ... 95

203121

208 ... 223

203114

96 ... 111

203122

224 ... 239

203115

112 ... 127

203123

240 ... 255

16 combined special flags

203132

2048 ... 2063

203140

2176 ... 2191

203133

2064 ... 2079

203141

2192 ... 2207

203134

2080 ... 2095

203142

2208 ... 2223

203135

2096 ... 2111

203143

2224 ... 2239

203136

2112 ... 2127

203144

2240 ... 2255

203137

2128 ... 2143

203145

2256 ... 2271

203138

2144 ... 2159

203146

2272 ... 2287

203139

2160 ... 2175

203147

2288 ... 2303

32 combined special flags

203124

2048 ... 2079

203128

2176 ... 2207

203125

2080 ... 2111

203129

2208 ... 2239

203126

2112 ... 2143

203130

2240 ... 2271

203127

2144 ... 2175

203131

2272 ... 2303

Application registers with overlaid flags

1000000

256 ... 287

1000028

1152 ... 1183

1000001

288 ... 319

1000029

1184 ... 1215

1000002

320 ... 351

1000030

1216 ... 1247

1000003

352 ... 383

1000031

1248 ... 1279

1000004

384 ... 415

1000032

1280 ... 1311

1000005

416 ... 447

1000033

1312 ... 1343

1000006

448 ... 479

1000034

1344 ... 1375

1000007

480 ... 511

1000035

1376 ... 1407

Summary of Contents for JVM-104-O08

Page 1: ...User Manual JVM 104 O08 We automate your success...

Page 2: ...the original User Manual Revision 4 10 1 Date of issue 1 31 2020 This document has been compiled by Jetter AG with due diligence and based on the known state of the art Revisions and further developme...

Page 3: ...tions 10 4 1 Dimensions 10 4 2 Electrical properties 10 4 3 Mechanical specifications 10 4 4 Environmental conditions 11 4 5 Display 11 4 6 Acoustic signal generator 11 4 7 Ports and interfaces 11 4 7...

Page 4: ...ting system via programming tool 29 7 6 2 Performing an OS update via JetEasyDownload 29 7 7 Application program 30 8 Registers Overview 31 8 1 Default address on the CANopen bus 31 8 2 General overvi...

Page 5: ...Jetter AG Table of contents JVM 104 O08 User Manual v 10 1 Customer service 40 11 Spare parts and accessories 41 11 1 Accessories 41...

Page 6: ...ervice Start Jetter We automate your success For further information refer to the following information products Version updates Information about new versions of software products or of the operating...

Page 7: ...in the technical specifications Intended use of the product includes its operation in accordance with this man ual SELV PELV If this device is not used in a vehicle or mobile machine a SELV or PELV p...

Page 8: ...elf propelled machines 3 1 Design 1 13 12 9 3 4 8 10 2 6 7 5 11 11 11 11 Fig 1 Device configuration 1 TFT display 2 F3 key 3 F4 key 4 Home key 5 ESC key 6 Digipot 7 Scroll key 8 Power key 9 F1 key 10...

Page 9: ...M 104 O08 User Manual 9 44 3 3 Nameplate Fig 2 Nameplate 1 Logo 2 Serial number 3 Barcode 4 Article number and hardware re vision 5 Model code number 3 4 Scope of delivery Scope of delivery Item numbe...

Page 10: ...ent 2 A Typical current consumption logic circuit VBAT_ECU 170 mA at DC 12 V 90 mA at DC 24 V Power consumption Approx 2 W Integrated protective func tions Reverse polarity protection overvoltage volt...

Page 11: ...t screen monitor Resolution 320 x 240 pixels Size 3 5 Background lighting LED typically 350 cd m2 dimmable Horizontal viewing angle 70 to each side Vertical viewing angle 50 from above 70 from below T...

Page 12: ...unshielded Tab 8 CAN interface specification Line lengths The maximum permitted cable length depends on the baud rate used and the number of CANopen devices connected Baud rate Max line length Max stu...

Page 13: ...fications 4 JVM 104 O08 User Manual 13 44 ESD EN 61000 4 2 ESD EN 61000 4 2 Values Functional class Contact discharge 4 kV to conductive sur faces A Discharge through air 8 kV to insulating sur faces...

Page 14: ...ation must allow air to circulate The installation location must be of sufficient size The device must be easily accessible to allow for service work Space required for installation and ser vice It sh...

Page 15: ...ll consisting of mounting plate and screws for housing with Deutsch or M12 connector without RAM mount attachments 10001621 OR Mounting plate for RAM Mount arm with suction cup consisting of mounting...

Page 16: ...nt ball 6 Alternate position of the RAM Mount ball 1 Screw the desired RAM Mount attachments onto the mounting plate 2 Hold the JVM 104 O08 against the mounting plate from behind The connec tors must...

Page 17: ...Jetter AG Mechanical installation 5 JVM 104 O08 User Manual 17 44 Fig 7 Installing the strain relief...

Page 18: ...ss may cause mechanical stress Protect the cables from bending twisting or chafing Install strain reliefs for the connecting cables NOTICE Surges resulting from missing protection or fusing Surges may...

Page 19: ...key is in position Ignition ON INFO Current consumption When the JVM 104 O08 is energized the current consumption is temporarily higher To ensure a reliable start up of the device provide at least 3...

Page 20: ...rty deviates from the default properties listed below Property Standard design Type of access Read write Value after reset 0 or undefined e g revision version number Takes effect Immediately Write acc...

Page 21: ...X functions are used in the communication between the JVM 104 O08 and other CANopen nodes The JVM 104 O08 supports the following STX functions Features Description CanOpenInit The function CanOpenInit...

Page 22: ...RD Server 3 SDO parameter SDO parameter R W 1203 RECORD Server 4 SDO parameter SDO parameter R W INFO Further information about this subject can be found in the topic CANopen Ob ject Directory in the...

Page 23: ...in the CPU or in separate I O modules 7 4 2 Operating system memory The OS is stored to a non volatile flash memory in the CPU Therefore the OS can be executed immediately after the device is powered...

Page 24: ...d for directory and file names The location of the directories App and Data is on the flash disk drive 7 4 6 Storing registers and variables Storing to a non volatile remanent memory Registers and var...

Page 25: ...signed to permanent addresses MX When the operating system is launched special flags are initialized using their default values Quantity 256 Flag numbers 2048 2303 Type of access By JetSym From HMIs F...

Page 26: ...ers with a corresponding sample program Digipot registers Register Description 363000 This register holds the current count value If you turn the digipot the count value increments or decrements Where...

Page 27: ...for prompting the state of the ignition Where If then Bit 0 0 Ignition is switched on and voltage is present at terminal 15 Ignition Bit 0 1 Ignition is off and no voltage is present at terminal 15 I...

Page 28: ...for the Shutdown function has the value false This means that the device will switch off Var Ignition Int At VL 361100 End_Var Task Ign Autorun Loop When Ignition Continue Delay 3000 Shutdown False E...

Page 29: ...ss is completed 5 To activate the newly installed OS re boot the device 7 6 2 Performing an OS update via JetEasyDownload To update the operating system of a JVM 104 O08 use a Peak CAN dongle and the...

Page 30: ...ription Startup Section name Project Path to the application program file This path is rela tive to app Program Name of the application program file Example Startup Project test_program Program test_p...

Page 31: ...999 Display 1000000 1029999 Application registers non volatile 8 3 I Os General overview Register areas Description 361000 361007 Bit coded map of input keys 8 4 Flags General overview Register ranges...

Page 32: ...0708 Day 100709 Month 100710 Year Identification 100950 Internal version number 100951 Module ID 100952 100962 Module name register string 100965 Config ID 100966 Vendor ID 100967 Variant ID 100968 Ty...

Page 33: ...running 200008 Error register identical with 210004 Bit 8 Illegal jump Bit 9 Illegal call Bit 10 Illegal index Bit 11 Illegal opcode Bit 12 Division by 0 Bit 13 Stack overflow Bit 14 Stack underflow B...

Page 34: ...13 Stack overflow Bit 14 Stack underflow Bit 15 Illegal stack Bit 16 Error when loading the application program Bit 24 Timeout Cycle time Bit 25 Timeout Task lock Bit 31 Unknown error 210006 Highest t...

Page 35: ...a file function Register ranges Description 312977 Status of file operation 312978 Task ID 8 13 Application registers Register ranges Description 1000000 1005999 32 bit integer remanent 8 14 Display R...

Page 36: ...gs 203132 2048 2063 203140 2176 2191 203133 2064 2079 203141 2192 2207 203134 2080 2095 203142 2208 2223 203135 2096 2111 203143 2224 2239 203136 2112 2127 203144 2240 2255 203137 2128 2143 203145 225...

Page 37: ...19 1000024 1024 1055 1000052 1920 1951 1000025 1056 1087 1000053 1952 1983 1000026 1088 1119 1000054 1984 2015 1000027 1120 1151 1000055 2016 2047 8 16 System Functions For reasons of compatibility th...

Page 38: ...function 50 Function QSort DataPtr Int ElementCnt Int Element Size Int SortOffset Int SortType STXBASETYPE SortMode QSORTMODE Int 90 91 Function FileDAWrite Const Ref FileName String Const Ref Mode S...

Page 39: ...vice and its functions are not allowed In the case of modifications to the device any liability is excluded The original parts are specifically designed for the device Parts and equipment from other m...

Page 40: ...r use the contact form on our homepage Technical hotline Jetter We automate your success You are also welcome to send an e mail to our technical hotline hotline jetter de Please supply the following i...

Page 41: ...be obtained from Jetter AG Accessories Item number Mounting plate for RAM Mount ball consisting of mounting plate and screws for housing with Deutsch or M12 connector without RAM Mount attachments 100...

Page 42: ...Device configuration 8 Fig 2 Nameplate 9 Fig 3 Dimensions in mm 10 Fig 4 Space requirements for installation work in mm 14 Fig 5 All dimensions of screw holes are in millimeters 15 Fig 6 Installation...

Page 43: ...e 12 Tab 8 CAN interface specification 12 Tab 9 Line lengths 12 Tab 10 Pulses to ISO 7637 2 12 Tab 11 Irradiation to ISO 11452 12 Tab 12 ESD EN 61000 4 2 13 Tab 13 Unsuitable installation locations 14...

Page 44: ...60884475 We automate your success Jetter AG Graeterstrasse 2 71642 Ludwigsburg www jetter de E mail info jetter de Phone 49 7141 2550 0...

Reviews: