![Jetter JetWeb JX2-PRN1 Operator'S Manual Download Page 22](http://html1.mh-extra.com/html/jetter/jetweb-jx2-prn1/jetweb-jx2-prn1_operators-manual_646592022.webp)
5.1 Description of Connections
JetWeb
22
Jetter AG
5.1.1
Register Description
*)
Once a character is entered into this register, this character is sent to the printer.
Prior to sending this character, a STROBE pulse with a pulse length of 5
µ
s is
generated and sent.
The status register is bit-coded, i.e. each bit indicates a specific state.
The status register is cleared when reading.
Note!
With the JX2-PRN1 module, register
3yy0
has got no function.
Register 3yy1: Data Register
Function
Description
Read
Last sent character
Value following reset: 0
Write
Sending the character to the printer
*)
Value Range
0 .. 255
Register 3yy2: Status register
Function
Description
Read
present interface state
Bit 0: 1 = No function
Bit 1: 1 = No function
Bit 2: 1 = No function
Bit 3: 0 = Error message
Bit 4: 1 = Printer is online
Bit 5: 1 = Paper tray is empty
Bit 6: 0 = Acknowledge
Bit 7: 0 = Printer is busy
Value following reset: Depending on printer status
Write
Illegal
Value Range
0 .. 255
Note!
In case the printer is ready, register
3yy2
contains the value 223 (0xDF)