3.8.4
Switching operations in the motor cable
NotICe
Switching operations in the motor cable are not permitted. Failure to do so
may result in malfunctions and lead to the servo amplifier being switched
off. It cannot be ruled out that switching operations in the motor cable may
destroy the servo amplifier.
To safely interrupt the power supply to the servomotor, the safety function
STO is available (see „Standardausführung S1“ auf Seite 75).
3.9
encoder connection
All encoder connections are located on the top of the device.
encoder connection of
Jetter motors
To connect synchronous motors by Jetter AG, use pre-assembled motor
and encoder cables from Jetter AG (see Accessories Catalog).
Matching of motor
encoder cable and servo
amplifier
Compare the nameplates of the components. Make absolutely sure that
you use the correct components according to the respective variant (A, B
or C)!
Resolver
high-resolution encoder
HIPERFACE®/
SSI/EnDat 2.1 interface
high-resolution encoder
HIPERFACE-
DSL® interface
Variant
D
Variant
B+C
Variant
A