Sample installation: Installation surface with drilling
holes
No.
Description
No.
Description
1
Screw, e. g. 6 x M8 x 20,
galvanized
Strength class: 8.8
4
Drilled hole without thread in
the mounting surface
The mounting surface must
have a thickness of 5 mm
min. It must be
heat-conducting.
2
Lock washer, 6 x M8
5
Lock washer, 6 x M8
3
Mounting strap of the device
6
Lock nut, 6 x M8, galvanized
Strength class: 8
Installation instructions regarding EMI
The surface of the mounting panel must be conductive for
reasons of sufficient bonding between controller, mounting panel
and the machine.
Avoid coated areas of the mounting panel, or else use lock
washers instead of plain washers.
Install the shielding of connecting cables on conductive
surfaces, such as the chassis.