Jetter AG
Product description | 3
JCM-501-E00 User Manual
9 / 59
3.3.1 Diagnostics capabilities by means of status indication
Colors and flashing patterns of the LEDs are an excellent source of information to
analyze problems.
Diagnostics via the setup window of the JetSym software is another option.
LED
Status
Color
Description
D2
OFF
---
This LED is controlled by register 108008. If bit
2 and bit 3 of register 108008 are 0 at the same
time, the LED is off.
ON
Red
Bit 3 is set in register 108008.
ON
Green
Bit 2 is set in register 108008.
ON
Orange
In register 108008, bits 2 and 3 are set simulta-
neously.
D1
OFF
---
This LED is controlled by register 108008. If bit
0 and bit 1 of register 108008 are 0 at the same
time, the LED is off.
ON
Red
Bit 1 is set in register 108008.
ON
Green
Bit 0 is set in register 108008.
The system is switched on (MR 108008=1).
ON
Orange
In register 108008, bits 0 and 1 are set simulta-
neously.
3.4 Scope of delivery
Scope of delivery
Item number
Quantity
JCM-501-E00
10001811
1
Installation manual
60884761
1
3.5 Nameplate
Fig. 3:
Nameplate
1
Logo
2
Serial number
3
Barcode
4
Article number and hardware re-
vision
5
Model code number