 2  New Features 

2.1 Festo CPX-CP Interface 

The CPX-CP interface is an expansion module for the CPX terminal of the 
Festo AG & Co. KG. The CPX-CP interface serves to connect the fitting CPI 
modules by Festo (CP valve terminals and CPI-I/O modules). 

Introduction 

 

 

192 digital inputs and 192 digital outputs can be directly connected to a 
CPX-FB14 

 

Further, up to 4 analog inputs and outputs can be connected 

 

The individual modules of the CPX and CPI system have been specifically 
described in the documentation published by Festo AG & Co. KG. Giving heed 
to the safety regulations listed there, as well as only using the modules for 
their intended purpose are imperative. 

Documentation 
published by Festo AG & 
Co. KG 

 

The following hardware and operating system versions are required for 
applying the CPX-CPI interfaces to Jetter AG controllers: 

Required Hardware and 
Operating System 
Versions 

 

Module 

Comment 

As of Software 

Release 

JC-24x Controller 

3.26 

JX6-SB / JX6-SB-I 

JX6 submodule 

V 2.21 

CPX-CP-4-FB 

Festo: CPX-CP interface 

 

CPX-FB14 

Festo: CANopen field bus node 

 

 

This chapter contains the following topics: 

Contents 

 

Topic Page 

Restrictions at Using the CAN System Bus .................................................... 9
Access to the Modules at the CPX-CP Interface .......................................... 10

 
 
 

Jetter AG 

 

Summary of Contents for JC-24x

Page 1: ...JC 24x Version Update from V 3 25 to V 3 26 Revision 1 01 December 2008 Printed in Germany...

Page 2: ...cumented in every single case This User Manual and the information contained herein have been compiled with due diligence However Jetter AG assume no liability for printing or other errors or damages...

Page 3: ...X CP Interface 8 Restrictions at Using the CAN System Bus 9 Access to the Modules at the CPX CP Interface 10 3 Fixed Software Bugs 12 N_COPY_TO FROM 2 with more than 64 registers in mode 2 13 Writing...

Page 4: ...ou to Operating System Update Why add new functions to your controller fix software bugs make sure your controller is working with a definite OS version for example if a definite OS version has been r...

Page 5: ...in the support area or on the page of the JC 24x controller via quicklink Downloading the OS File To update your OS proceed as follows Operating System Update by means of JetSym Step Action 1 Downloa...

Page 6: ...es and fixed software bugs in OS version 3 26 V 3 26 Feature New Bug Festo CPX Terminal Support for CPX CPI interface N_COPY_TO FROM 2 More than 64 registers in copy mode 2 BWU1821 Communication via c...

Page 7: ...the controller JC 24x By updating your OS you are given the possibility to enhance the functionality of your controller To do so you need the following Introduction an OS file the software tool JetSy...

Page 8: ...ed by Festo AG Co KG Giving heed to the safety regulations listed there as well as only using the modules for their intended purpose are imperative Documentation published by Festo AG Co KG The follow...

Page 9: ...reduced Restrictions at Connecting Analog I Os If at the CP string 1 or 2 Then the number of CP CPI output modules are connected the analog outputs is reduced to 8 CP valve terminals are connected th...

Page 10: ...13 CP CPI input modules IN 7201 7232 14 CP CPI input modules IN 7233 7264 The I Os at the JC 647 connected with the JX6 SB I submodule are numbered in analogy with the I O numbering at the JC 24x The...

Page 11: ...strings 3 and 4 are represented by the next but one I O module number The numbers of the additionally occuppied I O modules are entered into the module array as a virtual CPX FB14 Entries in the Modul...

Page 12: ...system release Introduction This chapter contains the following topics Contents Topic Page N_COPY_TO FROM 2 with more than 64 registers in mode 2 13 Writing Commands to the BWU1821 14 Reading and Wri...

Page 13: ...addressed The following revisions are affected by this bug Affected Revisions OS revision JC 24x JC 24x STX JM D203 JC24x 3 26 0 00 10 04 0 00 1 13 0 00 Hardware revision not applicable Configuration...

Page 14: ...to profile 7 4 Reading input data of AS interface slaves according to profile 7 4 Writing output data to AS interface slaves according to profile 7 4 The following revisions are affected by this bug A...

Page 15: ...The following revisions are affected by this bug Affected Revisions OS revision JX6 SB I JC 24x JM D203 JC24x 2 21 0 00 3 26 0 00 1 13 0 00 Hardware revision not relevant Configuration or operating m...

Page 16: ...21 0 00 3 26 0 00 1 13 0 00 Hardware revision not relevant Configuration or operating mode not relevant Comment 698 Carry out the following steps for a workaround Remedy Workaround Step Action 1 Star...

Page 17: ...Revisions OS revision JC 24x JM D203 JC24x 3 26 0 00 1 13 0 00 Hardware revision not applicable Configuration or operating mode not applicable Note none There is no remedy for affected revisions Remed...

Reviews: