TECHNICAL SPECIFICATIONS

Model(s) JetStream TREVI/TREVI LUX Typ 8203/2a/2aL

JetStream TREVI/TREVI LUX Typ 8203/7a/7aL

Characteristics:

8203/7a/7aL

8203/2a2aL

Power supply:

-

-

Nominal voltage:

230 V AC

400 V 3N AC

Rated frequency:

50 Hz

50 Hz

Rated input:

1,7 kW

2,5 kW

Protection class:

I

I

Protection:

IP 55

IP 55

Pump unit:
Nominal voltage:

230 V AC

400 V 3N AC

Rated frequency:

50 Hz

50 Hz

Rated input:

1,7 kW

2,5 kW

Current Rating:

7,9 A

4,3 A

Flow rate:

650 l / min.

720 l / min.

Head:

18m

19m

Floodlights:
Nominal voltage:

12V AC 50Hz SELV

12V AC 50Hz SELV

Rated input:

120 W

120 W

Protection class:

III

III

8.1 Dimensions: (230 V / 400 V)

gum buffer

fixing screw
with plug

water-
level

nozzle

insert of
cable
(standard
version)

special
version:
insert of
cable from below
(empty pipe)

9

CIRCUIT DIAGRAM FOR JETSTREAM TREVI,
TREVI LUX

9.1  With Single Phase Motor (TREVI 230 V)
       Mains 1 N 230 V AC 50 Hz

Pneumaticswitch

Pneumatic-

switch

Floodlight

12 V 100 W

Cable type

circuitbreaker

Cable type

Circuit

T 0,8 A

Reed-

switch

PE-

converter

T-hose

connector

Low

pressure

cable

Plug-in

inductor

Pumping set

F2 Circuit

T 0,8 A

Outlet box

Mains switch (Disconnector)

Fuse T 16 A

board

control

9.2   with Pneumaticswitch Mains 3 N 400 V 50 Hz

Fuse T 16 A

(inert) or. K-resp.

G - automat 6 A

Outlet box

Mains switch

(Disconnector)

F2 Circuit

T 0,8 A

circuitbreaker

Cable-type

board

control

Reed-

switch

Plug-in

inductor

Circuit

T 0,8 A

T-hose

connector

PE-

converter

Cable

type

Floodlight

12 V 100 W

Pneumaticswitch

Pneumaticswitch

Low

pressure

cable

Pumping set

Summary of Contents for TREVI

Page 1: ...TRANSLATION OF INSTALLATION AND OPERATING INSTRUCTIONS PAGE 10 17 TREVI TREVI LUX 230 V 400 V Read instructions...

Page 2: ...tructions from your dealer If technical problems should occur please contact the nearest customer service centre or your dealer TABLE OF CONTENTS PAGE 1 SAFETY INSTRUCTIONS 11 12 1 1 Before Setting in...

Page 3: ...swimming pools and in open air swimming pools with a water temperature up to 35 C The units are suitable for installing and operating in installations and rooms in areas 1 and 2 as per EN 60335 2 41 T...

Page 4: ...y you wish to massage Massage Hose accessory not included in the delivery Switch the JETSTREAM unit off before you fit or remove the massage hose Fit the massage hose onto the nozzle 2 and lock it in...

Page 5: ...ed 27 cm Further Installation Secure the unit together with the rubber buffer 4 to the pool wall The gap between the pool wall and the back of the housing submerged in the water must be at least 20 mm...

Page 6: ...uffer 55 min 25 max 80 2 400 V 2 230 V Measurements in mm rubber buffer 55 min 25 max 80 Width of equipment 350 mm Measurements in mm rubber buffer 55 min 25 max 80 Width of equipment 350 mm 3 230 V 3...

Page 7: ...r in the pump housing You must continue to fill the pump until the nozzle has its full power 5 ELECTRIC CONNECTION 5 1 Electric Connection Attention All work on stationary swimming pool pumps must onl...

Page 8: ...400 V 7 MAINTENANCE 7 1 Exchanging the Lamp TREVI LUX only Attention Dangerous voltage Unplug the unit from the mains Unscrew both countersunk screws M 8 x 60 from the ring of the lamp housing which s...

Page 9: ...ith plug water level nozzle insert of cable standard version special version insert of cable from below empty pipe 9 CIRCUIT DIAGRAM FOR JETSTREAM TREVI TREVI LUX 9 1 With Single Phase Motor TREVI 230...

Reviews: