17
Measurements in mm
8
TECHNICAL SPECIFICATIONS
Model(s) JetStream TREVI/TREVI LUX Typ 8203/2a/2aL
JetStream TREVI/TREVI LUX Typ 8203/7a/7aL
Characteristics:
8203/7a/7aL
8203/2a2aL
Power supply:
-
-
Nominal voltage:
230 V AC
400 V 3N AC
Rated frequency:
50 Hz
50 Hz
Rated input:
1,7 kW
2,5 kW
Protection class:
I
I
Protection:
IP 55
IP 55
Pump unit:
Nominal voltage:
230 V AC
400 V 3N AC
Rated frequency:
50 Hz
50 Hz
Rated input:
1,7 kW
2,5 kW
Current Rating:
7,9 A
4,3 A
Flow rate:
650 l / min.
720 l / min.
Head:
18m
19m
Floodlights:
Nominal voltage:
12V AC 50Hz SELV
12V AC 50Hz SELV
Rated input:
120 W
120 W
Protection class:
III
III
8.1 Dimensions: (230 V / 400 V)
gum buffer
fixing screw
with plug
water-
level
nozzle
insert of
cable
(standard
version)
special
version:
insert of
cable from below
(empty pipe)
9
CIRCUIT DIAGRAM FOR JETSTREAM TREVI,
TREVI LUX
9.1 With Single Phase Motor (TREVI 230 V)
Mains 1 N 230 V AC 50 Hz
Pneumaticswitch
Pneumatic-
switch
Floodlight
12 V 100 W
Cable type
circuitbreaker
Cable type
Circuit
T 0,8 A
Reed-
switch
PE-
converter
T-hose
connector
Low
pressure
cable
Plug-in
inductor
Pumping set
F2 Circuit
T 0,8 A
Outlet box
Mains switch (Disconnector)
Fuse T 16 A
board
control
9.2 with Pneumaticswitch Mains 3 N 400 V 50 Hz
Fuse T 16 A
(inert) or. K-resp.
G - automat 6 A
Outlet box
Mains switch
(Disconnector)
F2 Circuit
T 0,8 A
circuitbreaker
Cable-type
board
control
Reed-
switch
Plug-in
inductor
Circuit
T 0,8 A
T-hose
connector
PE-
converter
Cable
type
Floodlight
12 V 100 W
Pneumaticswitch
Pneumaticswitch
Low
pressure
cable