VFD Valve, Piston Complete

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. 054100973

Doc. Rev.: 8 (2022-03-04)

6

9

Unscrew and remove the Hose, steel 
braided (500mm) 

from the VPC-V 

Controller.

10

Remove the Gasket 

.

11

Remove the Hose (140mm) 

from 

the VPC-V Controller.

12

Remove the Distributor w/NR 
Valve 

NOTE: If the Distributor w/NR 
Valve is to be reassembled/
replaced, it is not recommended 
to remove the Distributor Clamp 
(unless it is damaged) from the 
assembly. 

For Distributor Clamp removal 
details, see disassembly 
information described in the 
technical data for the Distributor 
w/NR Valve.

13

Remove the two (2) screws (Screw, 
M5x10) 

.

14

Remove the Bracket BR1 

from 

the VPC-V Controller.

Service and Maintenance - Assembly Instructions

Assembly is to be performed in the reverse order of the disassembly procedure.

Scheduled Maintenance

Interval

Action

Note

Maintenance depends on flushes per 
year. This will vary depending on the 
segment i.e. ship, cabin, train, public, 
etc.

Inspect the discharge valve.  Clean 
and change any worn parts, if 
necessary.

The shut off membrane is normally the 
first item that needs to be replaced.

The piston valve has been tested and has reached 200,000 
flushes without any need of maintenance.

Troubleshooting

Jets Vacuum AS provides the following troubleshooting information to assist in resolving issues that may arise with your installation. For more 
detailed information or assistance, please contact Jets Vacuum AS.

Problem

Cause

Action

No reaction or insufficient flushing 
when pressing the release button.

No vacuum in the discharge pipe line.

Check the vacuum.

The release button does not open.

Replace the release button.

Dirt/blockage in the Non-return Valve, 
located on the toilet valve.

Clean the Non-return Valve.

Only flushing and no discharge is 
taking place.

The vacuum is below 25%.

Check the vacuum level and take action to increase the 
vacuum.

Summary of Contents for VFD Valve

Page 1: ...r products and services are offered and sold subject to Jets Vacuum AS General Sales Conditions copies of which will be furnished upon request Information provided herein is solely for information purposes does not constitute any warranty or representation of any kind and is subject to change without notice We strive to reproduce product colors reasonably accurate Without prior written approval th...

Page 2: ...VFD Valve Piston Complete Tel 47 70 03 91 00 www jetsgroup com Product No 054100973 Doc Rev 8 2022 03 04 2 Dimension Drawings A 235mm B 195mm C 290mm D 50mm E Ø60 ...

Page 3: ...the Source C Outlet from the Source D Air Inlet E D Valve Outlet Vacuum in the piping as indicated Normal Position Closed Valve VPC V Controller ℯ CLOSED D Valve Ⅎ CLOSED Emptying Sequence 1 Release Mechanism ℰ OPEN 2 VPC V Controller ℯ OPEN 3 D Valve Ⅎ OPEN Closing Sequence 1 Release Mechanism ℰ CLOSED 2 Air is sucked into the VPC Controller ℯ deciding the controller s timing 3 VPC V Controller ℯ...

Page 4: ...nce with the instructions provided Do not exceed the limits provided 2 2 Warning The client is responsible for installation service and maintenance by a qualified person 2 9 Warning Do not disassemble repair or modify the product without contacting a qualified tradesman 12 5 Notice Use this equipment only in the manner intended by Jets Vacuum AS If you have questions after reading these instructio...

Page 5: ...val of the valve Service and Maintenance Disassembly Instructions 1 Turn off the water supply to the valve Release any liquid in the water source i e toilet urinal etc 2 Pull the release mechanism hose from the controller 3 Remove the hose clip and pull to remove the flushing device 4 If a transport spring is installed release the spring connecting the lower housing of the valve to the bowl and re...

Page 6: ...nterval Action Note Maintenance depends on flushes per year This will vary depending on the segment i e ship cabin train public etc Inspect the discharge valve Clean and change any worn parts if necessary The shut off membrane is normally the first item that needs to be replaced The piston valve has been tested and has reached 200 000 flushes without any need of maintenance Troubleshooting Jets Va...

Page 7: ...elease button and the VPC V Controller is leaking Check the signal hose and connections for air leakages Replace if required The normal water level in the toilet bowl is reducing or low Low pressure on the water supply Increase pressure on the water supply Impurities prevent the shut off membrane from closing Lower housing to be cleaned Dirt in the water supply filter Clean or replace the filter S...

Reviews: