VAC Controller CVS/VIP
Tel. +47 70 03 91 00
www.jetsgroup.com
Product No. 121315143
Doc. Rev.: 5 (2020-11-30)
6
Operation
Start-up Procedures
First Start-up / Power-up the VAC Controller
At first start-up, CVS (Auto Mode) and English language is set as default. All vacuum and alarm settings are pre-set.
The VAC Controller is not a touch screen. Use the arrow keys to navigate through the system (refer to Navigation Principles below for more
information).
To change the mode for the VAC Controller, go to Operations menu 1:
1.1 - CVS (Auto Mode)
1.2 - Auto VIP Mode
1.3 - Manual Mode
1.4 - System Off
To change the date and time, go to Menu 2.6:
2.6.1 - Date
2.6.2 - Time
To change the language, go to menu 2.7.
Navigation Principle
● A dark frame around a setting or an arrow (►) insde the selection indicates which setting you are currently on.
● Arrow up/down indicates that there are several choices in the menu you are currently on.
● Activating and changing values occurs by having a blue frame around a current setting, then OK is pressed and the value begins to blink. Use
the arrow keys to adjust, then press OK or Done to save. The blinking will stop and the value will be saved.
● Each time a keystroke activates a button, a small beep will be heard, if the alarm sound is turned on/off in menu 2.6.8.
● Press and hold the return button for 5 seconds to restart the VAC Controller. The controller's long running time and warning tank level values
will reset.
● Press the return button to go back to the main menu.
Factory Settings
CVS (Auto Mode) and English language is set as default. All vacuum and alarm settings are pre-set.
The default setting is based on:
● The Vacuumarator™ is set to start at 30% vacuum, and stop at 50% vacuum.
● Maximum run time for the Vacuumarator™ is set to 10 minutes.
● Low vacuum alarm is set at 20%.
● Maximum run time after full tank alarm is 00 minutes.
● Vacuum if present setting is set at 5 minute delay run time.
If the default setting can be used, the system is ready for immediate use.
Manual Mode
Manual mode may be required in troubleshooting, i.e. to provide an extra powerful flush or when emptying a tank.
To run the Vacuumarator™ pump MANUALLY:
Go to Manual Mode in the Operations 1 menu. Press On to run the pump manually and Off to stop the pump. The pump will automatically
stop after the long running time is reached.
WARNING: The pump will not stop at high vacuum when in manual mode.