background image

VAC Controller CVS/VIP

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. 121315143

Doc. Rev.: 5 (2020-11-30)

6

Operation

Start-up Procedures

First Start-up / Power-up the VAC Controller

At first start-up, CVS (Auto Mode) and English language is set as default. All vacuum and alarm settings are pre-set.

The VAC Controller is not a touch screen. Use the arrow keys to navigate through the system (refer to Navigation Principles below for more 
information).

To change the mode for the VAC Controller, go to Operations menu 1:

1.1 - CVS (Auto Mode)
1.2 - Auto VIP Mode
1.3 - Manual Mode
1.4 - System Off

To change the date and time, go to Menu 2.6:

2.6.1 - Date
2.6.2 - Time

To change the language, go to menu 2.7.

Navigation Principle

● A dark frame around a setting or an arrow (►) insde the selection indicates which setting you are currently on.

● Arrow up/down indicates that there are several choices in the menu you are currently on.

● Activating and changing values occurs by having a blue frame around a current setting, then OK is pressed and the value begins to blink. Use 

the arrow keys to adjust, then press OK or Done to save. The blinking will stop and the value will be saved.

● Each time a keystroke activates a button, a small beep will be heard, if the alarm sound is turned on/off in menu 2.6.8.

● Press and hold the return button for 5 seconds to restart the VAC Controller. The controller's long running time and warning tank level values 

will reset.

● Press the return button to go back to the main menu.

Factory Settings

CVS (Auto Mode) and English language is set as default. All vacuum and alarm settings are pre-set.

The default setting is based on:

● The Vacuumarator™ is set to start at 30% vacuum, and stop at 50% vacuum.

● Maximum run time for the Vacuumarator™ is set to 10 minutes.

● Low vacuum alarm is set at 20%.

● Maximum run time after full tank alarm is 00 minutes.

● Vacuum if present setting is set at 5 minute delay run time.

If the default setting can be used, the system is ready for immediate use.

Manual Mode

Manual mode may be required in troubleshooting, i.e. to provide an extra powerful flush or when emptying a tank.

To run the Vacuumarator™ pump MANUALLY:

Go to Manual Mode in the Operations 1 menu. Press On to run the pump manually and Off to stop the pump. The pump will automatically 
stop after the long running time is reached.

WARNING: The pump will not stop at high vacuum when in manual mode.

Summary of Contents for 121315143

Page 1: ...ed herein is solely for information purposes does not constitute any warranty or representation of any kind and is subject to change without notice We strive to reproduce product colors reasonably accurate Without prior written approval this document or any part of may not be reproduced in any form Jets Vacuumarator Helivac VC VOD CVS and Softsound are trademarks and or registered trademarks of Je...

Page 2: ...ng Time Engages and activates alarm output I Vacuum Transmitter Fault Alarm is based on vacuum transmitter not connected connected wrong not working Full Tank Warning If the time setting in runtime after full tank has been set over 00 a pre warning alarm will sound This means that the pump will run in xx minutes before the full tank alarm sounds Start planning to have the tank emptied Operation AU...

Page 3: ...ning Avoid touching the connector with wet hands Do not disconnect the plug by pulling the electrical cord 2 14 Warning The equipment safety is guaranteed only if used in compliance with the instructions provided Do not exceed the limits provided 6 11 Notice Immediately upon receipt check the equipment for external damage Any damage detected after dispatch should be reported immediately to Jets Va...

Page 4: ...al information in this document The document contains important information related to the installation and settings for your installation Electrical Connections Diagram A Pre wired B Signal cable to the Vacuumarator pump C Vacuum transmitter D VIP signal optional E Tank level optional F Alarm Power on normally open contact G Alarm Low vacuum H Alarm Full tank I Alarm Long running time J Optional ...

Page 5: ... Installation Steps 1 Insert a screwdriver into both of the slots on the front cover to open the controller 2 Lift the display out of the housing 3 Using the four screw holes in the corners of the housing secure the controller to the wall screws not provided 4 Return the display back into position on the housing 5 Close both side covers Ensure both sides are locked in place ...

Page 6: ...Done to save The blinking will stop and the value will be saved Each time a keystroke activates a button a small beep will be heard if the alarm sound is turned on off in menu 2 6 8 Press and hold the return button for 5 seconds to restart the VAC Controller The controller s long running time and warning tank level values will reset Press the return button to go back to the main menu Factory Setti...

Page 7: ...umarator pump s power is disconnected the VAC Controller s power must also be disconnected 3 28 Warning Never work on the equipment when power is applied Setting Selections 1 Menu screen 2 Return Reset button 3 Scroll down button 4 Scroll right button 5 Scroll left button 6 Scroll up button 7 OK Save selection button 8 Power light Main Menu Vacuum Level Shows the current vacuum level Menu To enter...

Page 8: ...ent vacuum level 1 3 Manual Mode Manual start and stop of the Vacuumarator pump 1 4 System OFF ___________________________________________________________________________________________________________________ Main Menu 2 Selecting Menu from the main menu screen will take you to Main Menu 2 Alarm Alarm history Alarm setting Vacuum setting VIP setting Operation data Language Factory setting 2 1 2 ...

Page 9: ...newest alarm will show in the display when the history log opens ___________________________________________________________________________________________________________________ Alarm setting 2 3 2 3 1 Long running time Default 10 minutes Maximum constant pump running time 1 60 minutes 2 3 2 Low vacuum alarm Default 20 Low vacuum alarm 0 30 2 3 3 Runtime after full tank Default 0 minutes Maximu...

Page 10: ...twen set point in xx minutes after activated sensor or level switch 1 60 minutes ___________________________________________________________________________________________________________________ Operation data 2 6 2 6 1 Date Press OK and the value will blink Arrow up and down and press OK to set the day month and year 2 6 2 Time Press OK and the value will blink Arrow up and down and press OK to...

Page 11: ...ontroller Alarm sound ON default OFF function will deactivate all the sound from the controller alarm and key stroke sounds Alarm outputs NC default normally closed NO normally open alarm output Choose if alarm output long running time full tank and low vacuum should be normally open or normally closed Alarm output Power ON should always be pre set at NO and is not included in this selection This ...

Page 12: ...high level tank signal input is active closed signal The pump does not stop immediately but a running time count starts runtime after full tank alarm The runtime time is adjustable in the settings menu 2 3 3 The counter will be reset by a power failure The full tank alarm is activated The runtime after full tank time in alarm setting 2 3 3 can be adjusted Start planning to have the tank emptied Fu...

Reviews: