Jetmaster UNIVERSAL 850 Installation Instructions Manual Download Page 2

Jetmaster gas logs are fuel effect appliances intended for use in a

fireplace suitable for the burning of wood. It is recommended that

the Jetmaster gas log be placed in a properly installed Jetmaster

Convector firebox in order to ensure an adequate draught and

greater efficiency.The Jetmaster open fire is an approved open fire

to burn wood. The following size fireboxes are available for the 

Type 1 burner to be inserted into.The firebox can be installed into

an existing fireplace subject to the chimney being the appropriate

size and in sound condition. The firebox can also be installed from

new with a gather and flue.

( D I M E N S I O N S   I N   M I L L I M E T E R S )

A

A1

B

C

D

E

850

920

950

450

750

250

220

850 LOW

920

950

450

700

250

220

850 MK 4 gas log Burner. Suitable for model fireboxes 850 - 1050

IMPORTANT: An authorised person in accordance with the

manufacturer instructions should only carry out installation of this

appliance. All relevant codes including AS5601/A.G. 601 and

regulations laid down by the gas supply authorities, uniform building

regulations and the requirements of local municipal Authorities

must be observed.

Model Type  1 
Decorative Gas Log Fire 

8 5 0   G A S   L O G   B U R N E R

MODEL

WIDTH

HEIGHT

DEPTH

WEIGHT

850MK4

841mm

215mm

260mm

17kg

DATA PLATE: Refer to date place for information in respect of gas

pressure, consumption and gas type, Natural or LPG.The data place is

located to the side of the grate.

Location Requirements

1.

The fireplace construction must be non- combustible and in

accordance with the current Building Regulations for chimney and

fireplaces intended for solid fuel use.

2.

The flue and/or chimney should be tested and proven to have

an adequate updraft  which shall be sufficient to remove all waste

products of combustion. A minimum cross-sectional area of 40

000-sq. mm is required with a minimum chimney flue height of 3.6

meters. The installer must satisfy himself that the fireplace is

functioning properly and a smoke test is recommended.

3.

In cases where a twin walled metal flue is used and provided

such flue shall comply with the clearances specified in AS 2918

and AS5601 or manufacturer instructions in respect of clearances

to combustibles.

4.

A space of 40mm between the side wall of the fireplace and

grate is required.

5.

In cases where a metal flue is used, such flue shall comply

with the standards relating to grade, quality and thickness as are

current.

6.

An AGA approved flue cowl with a minimum cross-section of

40 000-sq. mm shall be affixed to the top of the flue or chimney.

Refer to AS5601 Clause 5.12.13.5.

7.

When the fire is installed into an existing firebox/fireplace,

the damper plate must be permanently fixed in the fully open

position. Refer  to AS5601  5.12.13.4. Where  a “Jetmaster”  firebox

is supplied as part of the Jetmaster Gas Log Fire Model 850 mark

4 appliance, the damper has been factory set and sealed and is not

to be adjusted.

8.

It should be noted that the Code AS2286 (Space heating

appliances-secondary guards) requires a dress guard to be affixed

to the appliance or fireplace.

9.

Ventilation- An opening to outside with a minimum free

ventilation area of 400 Square centimeters shall be provided for

each decorative gas log fire. Note: The chimney in which the

appliance is installed is not to be considered as ventilation

opening. Refer AS5601 Clause 5.12.13.2 and 5.12.13.3.

10. The appliance shall be installed into a fireplace with a minimum

opening of 850 width and 300mm depth 500mm height and shall be

no greater than 1050 mm width and 400mm depth and 530mm

height. (Note diagram indicating firebox sizes.)

11. Combustible materials to be no closer than 100mm either side

of fireplace opening and no closer than 150mm above the opening.

The firebox should have a non- combustible hearth in front of the

firebox.

Installation Instructions Jetmaster 850 Gas Log 

Electricity
Supply

Gas
Supply

Fan
Switch

Summary of Contents for UNIVERSAL 850

Page 1: ...Installation Instructions Jetmaster 850 Gas Log ...

Page 2: ...mum chimney flue height of 3 6 meters The installer must satisfy himself that the fireplace is functioning properly and a smoke test is recommended 3 In cases where a twin walled metal flue is used and provided such flue shall comply with the clearances specified in AS 2918 and AS5601 or manufacturer instructions in respect of clearances to combustibles 4 A space of 40mm between the side wall of t...

Page 3: ... control knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly depressed for 20 seconds Check that pilot stays lit If it goes out repeat ignition procedure MAIN BURNER IGNITION Depress and turn control knob anti clockwise from PILOT position to the ON positio...

Page 4: ... the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Log NO 6 10 9 and 4 mus...

Page 5: ...he centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear log in the position where the log reduces in height The charred end is located on the front log 3 with the charred effect facing toward the right hand side 4 LOCATE LOG NO 4 Place it on the left side of the rear log Charred end facing ...

Page 6: ... with a slightly blue flame After approximately 20 minutes the fire will settle down and burn with a yellow flame 3 As with all gas appliances your gas log fire should be regularly serviced We recommend once each year Contact your nearest Jetmaster authorised agent to provide service The routine for an authorised person to follow has been set out in an attached leaflet 4 PLEASE NOTE Only logs prov...