300
SUPER NOVA FULL MASONRY CHIMNEY
INSTALLATION
INSTALLATION INSTRUCTION
S/steel weather tray
With upstand
End open as smoke outlet
Register plate with
vented upstands
Minimum 600mm
below ceiling.
6” Flue
Bottom vent 240 x 90
Top vent 240 x 90
Directly below
register plate
300 min.
Firebox to
combustible
material
300 min.
Firebox to
combustible
material
Improved heating efficiency is achieved by admitting cool air into the brick cavity where it is heated by the
outer skin of the firebox and active flues, then released back into the room via hot air outlet vents.
NOTE: - Top of brick chimney can be left open, where no trees can cause a build up of leaves etc. on top
the weather plate. Weep holes must be left at weather tray level as no smoke outlet holes will be needed in
sides of chimney.
Weep holes
653
9
03/07/2017
Ver.7
6