background image

4

 

 

The data can be found on the data badge located at the left side of the inner fire box

 

 

Fire Details

 

 

Serial Number

 

 

Model

 

 

Installation Date

 

 

 

Purchased From

 

 

Name

 

 

Address

 

 

Tel

 

 

Date

 

 

 

Installation By

 

 

Installer Name

 

 

Company

 

 

Address

 

 

Tel

 

 

 

Commissioning

 

Please Circle One

 

 

Flue type correct

 

YES

 

NO

 

Flue swept and soundness checked

 

YES

 

NO

 

Smoke draw test (spillage) carried out

 

YES

 

NO

 

Air supply checked

 

YES

 

NO

 

Controls explained

 

YES

 

NO

 

HETAS Number

 

 

 

 

 

Signature

 

 

 

Print name

 

 

Summary of Contents for INSET STOVE MKIII 16i

Page 1: ...JETMASTER INSET STOVE MKIII 16i 18i 50i 60i 70i 60i Low 70i Low Installation Operating and Servicing Instructions Please leave these instructions with the customer...

Page 2: ...eparation for Fitting 13 Builders Opening 13 Inglenook Installations or freestanding 13 Appliance Preparation 14 Door Removal Replacement 14 Air Control Stop Low Rate Stop 15 Log Retainer Removal and...

Page 3: ...Removal 29 Lighting with Wood 29 Operation with door left open 29 Refuelling with Wood 29 Refuelling on to a low fire bed 30 Basket Grates 30 Lighting with Basket Grate 30 Use of the Air Supply Contro...

Page 4: ...llation Date Purchased From Name Address Tel Date Installation By Installer Name Company Address Tel Commissioning Please Circle One Flue type correct YES NO Flue swept and soundness checked YES NO Sm...

Page 5: ...133 4 133 4 133 4 133 4 133 4 133 4 in OUTPUTS WOOD Room size heated 70 100 130 150 200 130 170 M3 Total nominal heat output 3 6 4 9 6 3 7 5 10 6 5 8 5 kW Net efficiency 85 85 84 84 77 78 73 MINIMUM F...

Page 6: ...r design installation and commissioning of chimneys must be followed In your own interest and for safety in the United Kingdom it is the law that all solid fuel appliances are installed by competent p...

Page 7: ...or aesthetic reasons also this will help prevent the ingestion of any ash from the hearth into the air inlet Paint It is strongly recommended that the fire is protected from cement and plaster splashe...

Page 8: ...oor and the air control mechanism Ensure that all the listed items are present before commencing installation Firebox consisting of an outer box and an inner firebox Finishing Frame Flue Adaptor Roll...

Page 9: ...lations stipulate minimum clearance above windows and ventilation openings Pots should be simple open topped and with the same internal diameter as the flue Unconventional pots or terminals must be so...

Page 10: ...appliance See diagram Superimposed hearth must be 225mm forward from the front face of the appliance and 150mm each side from the edge of the appliance See diagram New hearths fireplaces recesses and...

Page 11: ...see if exposure to heat will cause damage Plastering Hot air can cause staining above the fire in the same manner as on the wall above a radiator This often shows more on lighter coloured finished sur...

Page 12: ...around the room DO NOT place an air supply inlet across the room from the fire The draught of cold air crossing the room will scour the room of warm air and the overall heating effect of the fire will...

Page 13: ...fit with the adaptor supplied Where a closure plate is required then it must conform to the Building Regulations The fire surround should be flat around the sealing area of the fire Check that the hea...

Page 14: ...te Stop Once the door has been removed the low rate stop will be visible This stop prevents the air control lever being slid to the fully closed position This will allow the fire to be turned down to...

Page 15: ...ackets Baffle Boards Upper baffle board and location brackets Tertiary Air Tube and Lower Baffle Removal and Replacement The sequence for easy removal of the air tubes and lower baffles are thus First...

Page 16: ...d The upper baffle is held in place between a recessed bracket in the back panel and a bracket at the top front that supports it The back of the upper board fits in a recess at the rear of the stove T...

Page 17: ...lacement Rear and Sides The internal boards need to be taken out in the following sequence IMPORTANT First remove the Ash Pan then the Bottom Grate followed by the Rear boards and then the Side boards...

Page 18: ...Firebox Engine Removal Finally with the adaptor removed the inner firebox engine can be removed To remove the inner firebox lift slightly at the front to disengage the 2 tags that locate the inner bo...

Page 19: ...amic insulation beneath the bricks to provide an expansion joint on top of the outer firebox in front of the adaptor to allow for expansion and contraction and to protect the wall above from excess he...

Page 20: ...rce An open grille maybe attached to the end of the flexible pipe to stop debris from blocking the pipe Ensure that the grille does not restrict the air supply The air requirements are listed in the d...

Page 21: ...en leave the door removed Check the door seals correctly if door fitted Check the operation of the air control to ensure that the linkage operates correctly Ensure that the low rate stop is fitted if...

Page 22: ...r own interest and for safety in the United Kingdom it is the law that all solid fuel appliances are installed by competent persons a registered installer or approved by your local building control of...

Page 23: ...as described in the appliance preparation section The upper baffle may be trimmed back by 25mm each end and each lower board baffle trimmed back 25mm from their outer edges Trimming can be carried ou...

Page 24: ...ssofmaterialsandshoulddisperseaftera few hours operation The user should be informed that the fire should be serviced annually and the chimney checked for flue pull and blockage Inform the customer of...

Page 25: ...r safety in the United Kingdom it is the law that all solid fuel appliances are installed by competent persons a registered installer or approved by your local building control officer The Heating Equ...

Page 26: ...e after being used a few times Safety Information Carbon Monoxide CO Alarm Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a...

Page 27: ...l will remain hot for a considerable length of time When operating the controls opening the door and re fuelling the fire ALWAYS WEAR A HEAT PROOF GLOVE Only genuine Jetmaster replacement parts shall...

Page 28: ...from side of fire frame to upright of surround 16i 300mm 12 100mm 4 150mm 6 18i 300mm 12 100mm 4 150mm 6 50i 350mm 14 100mm 4 150mm 6 60i 375mm 15 100mm 4 175mm 7 70i 450mm 18 100mm 4 200mm 8 60i Low...

Page 29: ...e door should be closed over but left slightly ajar for a period of up to 5 minutes until the fire is established This allows additional air into the fire reducing smoke emission and helps the glass t...

Page 30: ...Control The air control lever adjusts the primary air The secondary air supply is pre set to create simplicity for the user to operate just one control The primary and secondary air creates an air was...

Page 31: ...t of fuel specified in this manual should not be exceeded overloading can cause excess smoke Recommended Fuel Types The Jetmaster 16i 18i 50i and 60i Stoves have been assessed and been considered suit...

Page 32: ...the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance...

Page 33: ...g retainer as detailed in section on appliance preparation Tertiary Air Tube Lower and Upper Baffle Board Cleaning Remove the tertiary air tubes and baffle boards as detailed in appliance preparation...

Page 34: ...hinge and pull the old ceramic rope seal out of the recess Once removed clean any old adhesive out of the recess surfaces Spread a thin bead of sealer into the channel of the door frame To replace st...

Page 35: ...Maintenance To maintain the finish on Decorative Surrounds wipe with a soft damp cloth only Do not use abrasive cleaners polish or solvents as these can damage the surface finish The visible front pa...

Page 36: ...ion date for the second year of the standard warranty to be valid and within every 12 month anniversary thereafter to maintain the validity and coverage of any extended warranty For this purpose the i...

Page 37: ...rranty Fuels outside of this list are not covered by the warranty 4 Damage caused by burning material with high creosote content or any other painted treated timber 5 Consequential loss to associated...

Page 38: ...Contact Details Hunter Stoves Group 8 Emperor Way Exeter Business Park Exeter Devon EX1 3QS Email info hunterstoves co uk Web www hunterstoves co uk JINJMINA REV A 15 05 18 E OE...

Reviews: