Sensor MUI EX
-3-
C
– the set current has been exceeded and current alarm has been activated
D
– the measured current decreased beyond the set alarm value, alarm will be cut off. The measured
current decreased beyond the set level
Start Trigger
. The timer
Run Time
is switched off. Recording of
extremes and consumed capacity is going on.
Connection of the MUI Sensor
1.
The triple cable with JR connector can be connected directly to the JETIBOX (the connector marked
Pulse, + - ). Connect to the other JETIBOX input marked by (+ - ) the power supply voltage of 5-8,4V.
This connection mode does not take advantage of wireles data transmission, measured data are shown
directly on the JETIBOX LCD display. This mode does not allow acoustic alarm generation because the
siren is a part of the transmitter module which is not connected in this case. Alarms are only shown on the
LCD display.
2.
Connect the MUI sensor triple cable with JR connector to the DUPLEX receiver socket (marked Ext.)
on the receiver back side. For parameter setup connect the JETIBOX to the transmitter module. The MUI
sensor gets its power supply from the receiver.
3.
Connect the MUI sensor triple cable with JR connector to one of the EXPANDER inputs. The
expander renders it possible to connect several telemetric sensors to a single receiver. In this case the
MUI sensor gets its power suply from the Expander and the Expander from the receiver.
Firmware Update
The equipment firmware may be updated by a PC via the
converter unit JETI USB Adapter
. In the
USB Adapter instructions you will find a description of the installation procedure of the USB Adapter
controller as well as the update program.
Connection of the MUI Sensor
There are two inputs available at the MUI sensor, one for current measurement purposes (marked A)
and the other one for connection of the measured voltage (marked V).
The current must pass through the MUI, it is therefore necessary to connect it in series with the current
supply (battery). If the current polarity is reversed the sensor will show instead of the real current value
just 0 A. In that case reverse the current measurement input wires. Do not forget to use proper connectors
with sufficient load capacity for current measurements. For currents up to 30A we recommend G3,5
connectors, up to 75A G4 connectors and up to 150A G5,5 connectors or even better.