JETI model MUI EX Operation Manual Download Page 3

Sensor MUI EX

  

-3- 

C

 – the set current has been exceeded and current alarm has been activated 

D

  –  the  measured  current  decreased  beyond  the  set  alarm  value,  alarm  will  be  cut  off.  The  measured 

current  decreased beyond the set  level 

Start  Trigger

. The timer 

Run Time 

is  switched off. Recording of 

extremes and consumed capacity is going on. 

 
Connection of the MUI Sensor 
1.

  The triple cable with JR connector can be connected directly to the JETIBOX (the connector marked 

Pulse, + - ). Connect to the other JETIBOX input marked by (+ - ) the power supply voltage of 5-8,4V. 
This  connection  mode  does  not  take  advantage  of  wireles  data  transmission,  measured  data  are  shown 
directly on the JETIBOX LCD display. This mode does not allow acoustic alarm generation because the 
siren is a part of the transmitter module which is not connected in this case. Alarms are only shown on the 
LCD display.  

 

 

2.

  Connect the MUI sensor triple cable with JR connector to the DUPLEX receiver socket (marked Ext.) 

on the receiver back side. For parameter setup connect the JETIBOX to the transmitter module. The MUI 
sensor gets its power supply from the receiver. 

 

 

3.

  Connect  the  MUI  sensor  triple  cable  with  JR  connector  to  one  of  the  EXPANDER  inputs.  The 

expander  renders  it  possible  to  connect  several  telemetric  sensors  to  a  single  receiver.  In  this  case  the 
MUI sensor  gets its power suply from the Expander and the  Expander from the receiver. 

 

Firmware Update 

The  equipment  firmware  may  be  updated  by  a  PC  via  the 

converter  unit  JETI  USB  Adapter

.  In  the 

USB  Adapter  instructions  you  will  find  a  description  of  the  installation  procedure  of  the  USB  Adapter 
controller as well as the update program.   

 
Connection of the MUI Sensor

 

 

There are two inputs available at the MUI sensor, one for current measurement purposes (marked A) 

and the other one for connection of the measured voltage (marked V).  
The current must pass through the MUI, it is therefore necessary to connect it in series with the current 
supply (battery). If the current polarity is reversed the sensor will show instead of the real current value 
just 0 A. In that case reverse the current measurement input wires. Do not forget to use proper connectors 
with  sufficient  load  capacity  for  current  measurements.  For  currents  up  to  30A  we  recommend  G3,5 
connectors, up to 75A G4 connectors and up to 150A G5,5 connectors or even better. 