JETI model MUI EX Operation Manual Download Page 2

Sensor MUI EX

  

-2- 

MUI MENU

MIN / MAX

 – by pushing the button D (downward arrow) you will select the display of 

extreme  voltage  and  current  value  recordings  which  occurred  during  the  measurement.  The  extreme 
recordings are deleted automatically or they can be deleted in the menu 

Setting - Erase Data.

 Automatic 

deletion occurs when the MUI sensor has just been connected to the voltage supply and the current, as set 
in the menu 

Setting-Start Trigger,

 will be exceeded. If after connection of the sensor the set current will 

not be exceeded, values of the previous sensor operation will be displayed. 

U MIN / MAX

 – shows the minimum and maximum value of the measured voltage 

I AVG / MAX

 – shows the average value of the measured current and its maximum 

 

MUI MENU: 

Setting

 – by pushing the button D (downward arrow) you will enter the basic sensor setup 

menu   

Start  Trigger

  –  setup  of  a  current  value,  at  which  after  sensor  connection  recording  of  values  like 

minimum, maximum and  current transit time starts. If the adjusted value is 0 A, values will be recorded 
immediately after connection of the sensor to its power supply and data read out of the previous operation 
will not be possible.  

Erase  Data

  –  by  pushing  arrows  R  and  L  (right  and  left)  simultaneously  the  records  of  measured 

parameters will be deleted 

First Parametr

 – adjustment of the display of the first parameter in the JETIBOX LCD, which is shown 

in the second line of the basic sensor menu  (the first line  shows the identification, for instance SENSOR 
MUI 30)  

Second  Parametr

  -  adjustment  of  the  display  of  the  second  parameter  in  the  JETIBOX  LCD,  which  is 

shown  in  the  second  line  of  the  basic  sensor  menu  (the  first  line    shows  the  identification,  for  instance 
SENSOR MUI 30) 
Auto. Erase - This function of automatical deletion after overstepping the trigger level can be  activated or 
deactivated.  
 

MUI MENU: 

ALARMS

 – by pushing button D (downward arrow) you enter setup of particular alarms.  

If one of the adjusted parameters becomes exceeded, the JETIBOX LCD will  in the second line of the 
basic menu alternately show the original display with the pertinent alarm and the transmitter module siren 
will emit an acoustical alarm. The first tone is a revelation signal and the second one is signalling a Morse 
Code character of the relevant alarm. If the alarm is set to OFF, this kind of alarm will be switched off.  

Voltage  alarm

  –  (alarm  U 

..- 

)  adjustment  of  the  value  of  voltage  signalling,  if  the  measured  voltage 

decreases beyond the set value, the voltage alarm U will be activated.  

Current  alarm 

–  (alarm  I 

.. 

)  adjustment  of  the  value  of  current  signalling,  if  the  measured  current 

increases beyond the set value, the current alarm I will be activated.  

Capacity  alarm

  –  (alarm  C 

-.-. 

)  adjustment  of  the  signalling  value  of  consumed  capacity  ,  if  the 

adjusted value of maximum consumed capacity is exceeded, alarm C will be activated.  
 

MUI  MENU

SERVICE

  –  by  pressing  button  D  (arrow  down)  you  will  change  to  depiction  of  the 

firmware version and to renewal of the sensor default setting. 

Factory Defaults

 – by simultaneous pressing of arrows R and L (right and left) the factory settings of the 

MUI are loaded.  

MUI v. xx.xx ID xxxxx:xxxxx

 – product marking with firmware version and series number (ID). 

 

Particular phases of current measurements

 

A

  –  when  after  switching  on  of  the  sensor  the 

current  did  not  exceed  the  set  value 

Start  Trigger

Measured  values 

(U  MIN  /  MAX,  I  AVG  /  MAX, 

Capacity,  Run  Time)

  correspond  with  measured 

values of the previous operation. 

B

  –  the  value 

Start  Trigger 

has  been  exceeded

.

  

Previous measured values 

(U MIN /  MAX, I AVG / 

MAX,  Capacity,  Run  Time)

  will  be  deleted  and 

actualized by the actual measurement course. 

 

 

 

         