background image

EN

MAX BEC / SBEC

MAX BEC / SBEC

®

User manual

EN

MAX BEC / SBEC

MAX BEC / SBEC

Summary of Contents for MAX BEC

Page 1: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC User manual EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC...

Page 2: ...ettingandLEDfunction 7EN 2 3 2Wiring 8EN 2 3 3Switch 8EN 2 3 4ParametersMAXBEC2 9EN 2 4 MAXBEC2Dplus 10EN 2 4 1OutputvoltagesettingandLEDfunction 10EN 2 4 2Wiring 10EN 2 4 3Switch Magneticswitch 11EN...

Page 3: ...C30D 16EN 3 2 1Outputvoltagesetting 16EN 3 2 2 Wiring 16 EN 3 2 3Switch Magneticswitch 16EN 3 2 4Switch RCswitch 17EN 3 2 5Heatprotection 18EN 3 2 6 Setup 18 EN 3 2 6 1 Configuration via JETIBOX 18 EN...

Page 4: ...ch uses LiXX cells to power it The regulator ensures that the power supply to the servos is constant at all times and the result is the same speed of movement of the servos regardlessofthestateofdisch...

Page 5: ...oad occurs the output voltage decreases to zero untiltheshortcircuitoroverloadisremoved Its great advantage is that it allows the use of standard servos in systems designed for the so called High Volt...

Page 6: ...is above 7 0 V all three green LEDs are ON While the cells are gradually discharging particularLEDsgoOFFdependingoninputvoltage lowerthen7V 6 7V 6 45V If the input voltage is under 6 5V the red LED go...

Page 7: ...requested output voltage of the regulatorcan be adjustedin stepsof 5 0V 5 4 V 5 7V and 6 0V The MAX BEC 2 supply can consist of LiXX or NiXX cells For this purpose we recommend application of 2 LiXX...

Page 8: ...ies is equal current is drawn from both of them and LEDs of batteries 1 and 2 are ON There exists no energy exchange between the batteries if the voltages of both batteries are different therefore bot...

Page 9: ...e Output MPX connector Electronic switch LED Accu 1 2 Power input Accu 1 2 2 3 4 Parameters MAX BEC 2 Dimensions 100x29x16 mm Weight 85 g Recommended input voltage 5 5 8 4 V Input voltage max 16 V Out...

Page 10: ...and 6 5V If the input voltage becomeslower than 6 5 V the red LED lights up indicating discharged cells This shows in case of 2S LiXX batteries that the voltage per cell decreased below 3 25V 2 4 2 Wi...

Page 11: ...netickeyispresent buttheunitisnotswitchedonyet If the green LED is continuously active this indicates that the MAXBEC2D PLUS is active and ready to power your receiver and servos SafetyPrecautionsfort...

Page 12: ...eand separatethemagneticswitch 2 Connect MAX BEC 2D Plus with RC Switch conrol output using three wirecable 3 Bind the RC Switchwith your transmitterand configure it in main menu model deviceexplorer...

Page 13: ...r input voltage Pins for jumper selection of output voltage Output MPX connector LED Accu A B Power input Accu A B 13 EN 2 3 4 Parameters MAX BEC 2D plus Dimensions 100x29x16 mm Weight 85 g Recommende...

Page 14: ...egulator SBEC comprises two battery input cables with cross sections of 1mm2 as well as two pairs of output servo cables with cross sections of 0 5mm2 each These output cablesareequippedwithJR plugs 3...

Page 15: ...ustained current A 6 2 5 7 5 4 5 1 4 7 4 5 4 1 3 8 3 5 Sustainedcurrentvaluesarevalidonlyforoperatingconditions withsufficientcoolingairflow 3 1 5 ParametersSBEC Dimensions 60x28x10mm Weight 29g Recom...

Page 16: ...e external switch such as Universal Magnetic Switch or RC Switch On the output there are two cables with cross sections of 2 5mm2 which are connected to the receiver via MPX connector In addition SBEC...

Page 17: ...he magnetic switch and key Key Target Led ON SafetyPrecautionsfortheManipulationofMagnets Since the MAXBEC 2D Plus contains magnetic components it is necessary to follow some simple rules for the hand...

Page 18: ...gher Otherwise the output voltage may decline during the load The switch on state of the regulator is signaled by thegreenLED Notice 1 Always make sure that all the connected devices such as receivers...

Page 19: ...ection OutputVoltage actualvalueofBEC soutputvoltage Temperature actualtemperaturevalue in C Theitemsof MIN MAX Reset MIN MAX by pushing the arrows R and L left and right together the minimum and maxi...

Page 20: ...sfromthesensors Only keep the pin disconnected or connected to the common groundoftheSBEC30D 1 Contact end switch Typ 40kW FIG 8 Example of logic input connection 20 EN Toswitchbetweenitems presslefto...

Page 21: ...andnewer ThereceivermustbeconnectedtotheSBEC30DviaEXbus Transmitterfirmwareversion4 28andnewer FileSBEC30D binstoredinthe Devices folderonthetransmitter SDcard When everything is properly connected an...

Page 22: ...citytakenfromthebattery Temperature actualtemperatureoftheBEC TelemetryMin Max Clear Min Max switch here you can assign a control on the DC DStransmitterwhichclearsbatterycapacityandtherecorded minimu...

Page 23: ...ound in the user manualfortheUSBadapter oStarttheJETIStudioupdateprogramonyourPC o Connect the USB adapter via three wire cable to the main EXT of theSBEC30D redJRconnector o Connect the power supply...

Page 24: ...EC30D Dimensions 72x28x14mm Weight 50g Recommendedinputvoltage 6 42V Inputvoltagemax 59V Outputvoltage 5 0V 8 4V Sustainedcurrent 8 2A withsupply 2SLiXX seetab Peakcurrent 30A max 1s Number of Lixx ce...

Page 25: ...he assumption that it has been operated in conformity with these instructions at recommended voltages and that it has not been damaged mechanically Warranty and post warrantyserviceisprovidedbythemanu...

Page 26: ...public The stated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic...

Page 27: ...ated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic compatibilit...

Page 28: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC JETI model s r o Lomen 1530 742 58 P bor Czech Republic www jetimodel com www jetimodel cz info jetimodel cz 28 EN...

Reviews: