background image

JET   

 

Setup and Assembly 

Any missing parts or damage should be reported 
immediately to your JET

®

 distributor. Do not use a 

damaged  tool.  Read  this  instruction  manual 
thoroughly for operation, maintenance and safety 
instructions. 

Box contents: 

Pneumatic drill 

1  

Chuck key 

Dead handle 

(JAT-601 only)

 

Operation and parts manual  

Warranty card 

 

Model  JAT-601  only

:  To  install  dead  handle 

(Figure  1),  rotate  handle  counterclockwise  to 
loosen retainer; then slide retainer over chuck and 
onto drill body, and rotate to a convenient angle. 
Retighten handle to secure. 

Note: Chuck must remain clear of retainer. 

Operation 

 

The  pneumatic  drill  must  be 

properly  lubricated  before  operation.  See 
“Lubrication” section. 

 

 

Figure 1 

 

1. 

Remove protective cap from air inlet (Figure 
1). If an in-line oiler is not being used, add 4 
or 5 drops of air tool oil (not included) into the 
air inlet. 

2. 

Blow  out  air  line  to  remove  any  dirt  or 
moisture,  then  connect  air  supply  hose  to 
tool. Set air pressure to 90 psi. 

IMPORTANT:

  Connecting  a  quick-change 

coupling  directly  to  the  tool  is  not 
recommended,  as  vibration  may  cause  the 
connection to fail. Instead, add a leader hose 
and  install  any  quick-change  couplings 
farther down the line. 

3. 

Insert chuck key into one of the holes on the 
chuck, so it meshes with teeth on drill chuck. 
Rotate counterclockwise to open chuck jaws. 

4. 

Insert  bit  (not  provided)  into  chuck,  and 
center it between the jaws. Tighten chuck by 
hand while aligning bit.  

Note: Insert only the shank of a twist drill bit; 
its  flutes  should  remain  free  of  the  chuck 
jaws. 

5. 

Insert chuck key and rotate clockwise to fully 
tighten chuck. 

6. 

Select rotation direction (F/R). 

7. 

Place bit against work item and gently press 
trigger.  Speed  is  variable,  determined  by 
pressure  against  trigger.  Begin  at  slow 
speed and gradually increase as you drill. 

8. 

Release trigger to stop drill. 

Maintenance 

Lubrication 

The  drill  should  be  lubricated 

daily

  (or  before 

each  use)  with  air  tool  oil  through  the  air  inlet. 
During  continual  operation,  it  should  be  re-oiled 
every 1 to 2 hours. This can be done with an in-
line oiler, or manually. If done manually, proceed 
as follows: 

1. 

Disconnect air hose from tool. 

2. 

Place 4 or 5 drops of air tool oil into air inlet. 

NOTE: Air tool oil not provided; it is available 
at most major hardware and tool stores. SAE 
#10 oil or sewing machine oil may be used 
as a substitute. Do not use detergent oil. 

Summary of Contents for JAT-600

Page 1: ...c Reversible Drill 505600 JAT 600 505601 JAT 601 Operation Parts Manual M 505600 Edition 2 11p 2018 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET JAT 6...

Page 2: ...needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JE...

Page 3: ...against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol or any medicatio...

Page 4: ...ded for use with a pneumatic drill and which match the chuck size of the tool 37 Keep drill bits sharp and clean for best and safest performance 38 Make sure bit is centered between chuck jaws and sec...

Page 5: ...in this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense A...

Page 6: ...Power setting Variable speed trigger Variable speed trigger Grip Pistol style Pistol style Overall Length 7 3 16 in 182 58 mm 8 1 4 in 209 55 mm Housing material Aluminum Aluminum Net weight 2 49 lb 1...

Page 7: ...he connection to fail Instead add a leader hose and install any quick change couplings farther down the line 3 Insert chuck key into one of the holes on the chuck so it meshes with teeth on drill chuc...

Page 8: ...ize tool for the job Poor maintenance practices such as using excessive air pressure or air volume Improper or no lubrication Rule of Thumb If it takes more than 8 seconds to tighten or loosen a bolt...

Page 9: ...the environment Your tool contains materials which can be recovered or recycled When its useful life has expired please leave tool at a specialized facility Figure 2 Recommended arrangement of air pip...

Page 10: ...tion Bearings worn Disassemble and inspect bearing Grease or replace as needed Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator...

Page 11: ...llowing pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available wh...

Page 12: ...12 JAT 600 601 Pneumatic Drill 505600 JAT 600 3 8 inch Pneumatic Drill exploded view 3 33 32 2 1 13 11 14 17 18 15 16 14 19 13 17 7 5 31 6 9 10 8 4 23 25 24 28 22 38 28 26 34 29 35 30...

Page 13: ...80216 Rotor vane 5 17 JAT600 17 Spring pin 2 5x10L 1 18 JSM7572 18 Cylinder 1 Index Part No Description Qty 19 80219 Spacer 1 22 80222 Internal gear 1 23 JAT620 23 Planet gear 3 24 30124 Pin 4x13 8L 3...

Page 14: ...T 600 601 Pneumatic Drill 505601 JAT 601 1 2 inch Pneumatic Drill exploded view 3 33 32 2 1 13 11 14 17 18 15 16 14 19 13 17 7 5 31 6 9 10 8 4 38 20 23 25 24 27 21 23 25 24 26 28 28 22 22 36 29 37 30...

Page 15: ...SM7572 18 Cylinder 1 19 80219 Spacer 1 20 SM 70420 Pinion gear 1 Index Part No Description Qty 21 SM 70421 Center gear 1 22 80222 Internal gear 1 23 SM 70423 Planet gear 6 24 30124 Pin 4x13 8L 6 25 70...

Page 16: ...16 JAT 600 601 Pneumatic Drill 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...

Reviews: