8
JAT-450/451 Angle Grinder
NOTE: Air tool oil not provided; it is available
at most major hardware and tool stores. SAE
#10 oil or sewing machine oil may be used
as a substitute. Do not use detergent oil.
3.
Re-connect air. Run grinder at low throttle
without load for a few seconds to distribute
the oil throughout tool.
4.
When finished operating grinder, disconnect
air hose. Wipe off housing with a dry cloth.
Place 4 or 5 drops of air tool oil into air inlet;
re-connect air and run tool for a few seconds
to distribute the oil. Disconnect air.
The angle grinder has been pre-greased from the
manufacturer, and it is generally unnecessary to
grease the tool during its normal life. However,
should the tool require future servicing, a grease
fitting is supplied atop the housing. Use Lithium
Complex Moly 2 grease or equivalent.
Storage
Avoid storing the grinder in very humid locations
which promotes rusting of internal mechanisms.
Always oil the tool and disconnect air hose before
storage.
Air system requirements
1. Use proper air hose size (refer to tool
specifications). The hose should be just long
enough to serve the working area. Excessive
hose length will cause pressure drop.
2.
Make sure air compressor supplies clean,
dry air at correct CFM for the tool.
3.
Set air pressure to 90 psi.
Excess air pressure
and/or unclean air will shorten the tool’s
life and may create a hazardous situation.
4.
Drain water from air compressor tank daily,
as well as any condensation from air lines.
Water in the air line may enter the tool and
cause damage.
5.
Change filters on the air system on a regular
basis.
6. Air-line pressure may be increased
accordingly to compensate for extra-long air
hoses (usually over 25 feet). Inside diameter
of hose should be minimum 3/8-inch.
General Air Tool
Information
If the air tool is not performing according to
specifications, the following are among the most
common causes. (See also “Troubleshooting”
section.)
•
Contaminated air such as a dirty air system
or water in the system.
•
Using wrong size tool for the job.
•
Poor maintenance practices, such as using
excessive air pressure or air volume.
•
Improper or no lubrication.
Rule of Thumb
If it takes more than 8 seconds to tighten or loosen
a bolt or nut with an air impact wrench at
maximum setting, the air wrench is too small or
the air compressor CFM is not powerful enough
for the job. Continued use in either capacity will
cause damage to the tool.
Tool Pressure
JET Air Tools operate on 70-to-100 psi (pounds
per square inch) air pressure measured at the tool
when the tool is operating. Set tool to 90 psi
unless indicated otherwise. Pressure in excess of
100 psi will shorten the life of the tool.
Air System Recommendations
Equip the air compressor intake with a
replaceable air filter that can be easily cleaned.
Use safety shut-off valves so air flow can be
stopped quickly in case of a line break.
When using multiple hoses, air hoses should be
larger than leader hose. Join multiple hoses
directly, rather than with quick connect fittings
which may cause pressure drops and tool power
reduction.
Use anti-whip devices across hose couplings to
prevent hose from whipping in the event of a hose
failure or coupling disconnect.
Summary of Contents for JAT-451
Page 12: ...12 JAT 450 451 Angle Grinder 505450 JAT 450 4 inch Angle Grinder exploded view...
Page 14: ...14 JAT 450 451 Angle Grinder 505451 JAT 451 5 inch Angle Grinder exploded view...
Page 16: ...16 JAT 450 451 Angle Grinder 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848...
Page 17: ...JET 17 www jettools com...