background image

3.0 

VII Electric 

 
ELECTRICAL CONNECTION/DISCONNECTION & OPERATION 

 

For three phase : 

1. 

Electrical connection: 

1. 

A cable with four wires is equipped to connect your machine into the 3 phase power supply. 

Please connect your machine into the power supply with hand-operated disconnecting 
device,

 which is in compliance with subclause 5.3 of EN 60204-1, such as on fuse breaker or 

plug/socket combination. 

2. 

For the protection of control device, we recommend the operation to supply 

a fuse with 6 A 

current rating of fuse, 

and the total length between fuse and connection terminal shall not 

exceed 1.5m. 

3. 

The

 exact power source voltage, frequency, and number of phase 

shall be checked 

according to the installation diagram and circuit diagram.

 

4. 

The correct direction of drilling press should be checked after connecting. 

   

2. 

Electrical disconnection: 

1. 

The disconnection is carried out by hand-operated disconnection device. 

2. 

Be sure to disconnect this machining from power source, when you want to stop the job,  
Maintenance, and adjustment. 

 

3. 

Grounding  

   The grounding of the drilling press is carried out

 by connecting the Yellow/Green terminal of 

supply cable 

to the grounding terminal of power source. Be sure to ground your machine before 

connecting machine to power source in any situation. 

 

 
    Do not disconnect grounding terminal before disconnecting power source. 
 
  
 For single phase : 

1. 

The connect, disconnection, and grounding is carried out 

through the plug, 

equipped on the 

drilling press. For the safety reason, 

Do not change this plug into any the other type in any 

situation. 

2. 

For the protection of control device, we recommend the operated to supply 

a fuse with 8 A 

current rating of fuse,

 and the total length between buse and connection terminal shall not 

exceed 1.5m.

 

3. 

The 

exact power source voltage, frequency, and number of phase

 shall be checked according 

to the installation diagram and circuit diagram.

 

 

 Operation: 

 

1. 

"START"

 : Push the button marked with 

" I "

.

 

2. 

"STOP"

: Push the button marked with 

" O ". 

3. 

"Interlock Switch"

: Limit switch in the pulley cover.

 

4. 

“Limited Switch

”: Chuck guard disconnection

 

5. 

“Emergency Switch”

Button with 

”RED” 

   
 

Do not stop machine with interlock switch in normal operation. 

 

 

WARNING ! 

WARNING ! 

Summary of Contents for IDP-15BV

Page 1: ...IDP 15BV DRILL PRESS Original GB Operating Instructions JPW Tool AG Tämperlistrasse 5 CH 8117 Fällanden Switzerland Phone 41 44 806 47 48 Fax 41 44 806 47 58 www jettools com M 50000986M 2017 05 ...

Page 2: ...Directive Maschinenrichtlinie Directive Machines 2014 30 EU electromagnetic compatibility elektromagnetische Verträglichkeit compatibilité électromagnétique designed in consideration of the standards und entsprechend folgender zusätzlicher Normen entwickelt wurde et été développé dans le respect des normes complémentaires suivantes EN ISO 12100 2010 EN 12717 2001 A1 2009 EN 60204 1 2006 A1 2009 EN...

Page 3: ...ely blocked and clamped 6 The chuck shall be securely fastened to the spindle and so that it can t separate from spindle 7 Remove Key from chuck after adjustment 8 The tool is to be disconnected from the power supply while the motor is being mounted connected or reconnected 9 Secure the tool to the supporting structure if during normal operation there is any tendency for the tool to tip over slide...

Page 4: ...job Maintenance and adjustment 3 Grounding The grounding of the drilling press is carried out by connecting the Yellow Green terminal of supply cable to the grounding terminal of power source Be sure to ground your machine before connecting machine to power source in any situation Do not disconnect grounding terminal before disconnecting power source For single phase 1 The connect disconnection an...

Page 5: ...removal 8 5 4 3 Wrench and key storage 8 6 0 ELECTRICAL CONNECTIONS 9 6 1 GROUNDING INSTRUCTIONS 9 6 2 EXTENSION CORDS 9 7 0 ADJUSTMENTS 9 7 1 DEPTH STOP ADJUSTMENT 9 7 2 RETURN SPRING ADJUSTMENT 10 7 3 TABLE TILT ADJUSTMENT 10 8 0 OPERATING CONTROLS 10 9 0 OPERATION 10 10 0 USER MAINTENANCE 11 10 1 LUBRICATION 11 11 0 TROUBLESHOOTING IDP 15BV 12 12 0 REPLACEMENT PARTS 13 12 1 1 IDP 15BV DRILL PRE...

Page 6: ...meter 52mm Number of spindle speeds Variable speed change Maximum no load speed range 450 2000 RPM Maximum spindle to table distance 470mm Maximum spindle to base distance 640mm Maximum chuck to table distance 381mm Maximum chuck to base distance 551mm Drilling capacity cast iron 20mm Drilling capacity mild steel 16mm Materials Head cast iron Table milling cast iron Column steel Forming Base cast ...

Page 7: ...olumn diameter 73mm Dimension and Weights Overall dimensions assembled 565 x 350 x 980mm Net weight approximate 51 kg Shipping weight approximate 53 6kg L length W width H height D depth The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice withou...

Page 8: ...lling crank handle 5 4 1 Chuck and arbor installation 1 Thoroughly clean arbor A Figure 6 2 chuck B and spindle C Any grease or residue in these areas can cause the pieces to separate and create a safety hazard as well as damage to the tool Twist chuck to retract chuck jaws if they are exposed Push chuck B by hand onto arbor A and slide assembly firmly up into spindle C Turn arbor and chuck assemb...

Page 9: ... conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Use only 3 wire extension cords that have 3 prong grounding plugs and 3 pole receptacles that accept the tool s plug Repair or replace damaged or worn cord immediately 6 2 Extension cords The use of extension cords is discouraged try to position machines...

Page 10: ...loosen This could cause table assembly to separate from column fall and cause injury 1 IDP 15BV Loosen set screw H with 1 4 hex wrench 2 IDP 15BV Loosen hex cap screw J with 5 8 or adjustable wrench 3 Tilt table to desired angle referring to scale and pointer atop table bracket 4 Tighten screw or nuts J 5 Tighten set screw H Figure 8 4 table tilt IDP 17 only 8 0 Operating controls Press ON button ...

Page 11: ...o comply may cause serious injury A coat of automobile type wax applied to table and column will help keep surfaces clean Check that bolts are tight and electrical cords are in good condition If an electrical cord is worn cut or damaged in any way have it replaced immediately In dusty environments frequently blow out any dust that accumulates inside the motor fan cover Belts should be in good cond...

Page 12: ... or bit Retract drill bit frequently to remove chips Dull drill bit Resharpen or replace drill bit Feeding too slowly Increase feed rate Drill bit wanders Bit sharpened incorrectly Resharpen bit correctly Bent drill bit Replace drill bit Bit or chuck not installed properly Reinstall the chuck or bit properly Wood splinters on the underside No backing board used Place a scrap board underneath the w...

Page 13: ...ment parts are listed on the following pages Some parts are shown for reference only and may not be available individually Non proprietary parts such as fasteners can usually be found at local hardware stores or may be ordered from JET ...

Page 14: ...14 12 1 1 IDP 15BV Drill Press Exploded View ...

Page 15: ...12V026 Motor 2HP 1 PM 212V026 01 Carbon Brush 2 PM 212V026 02 Terminal To Carbon Brush 2 27 PM 212V027 Screw 5 16 x 3 8 2 28 PM 212V028 Pen 5 x 25 1 29 PM 212V029 Motor Plate 1 30 PM 212V030 Washer 5 16 x 5 x 5 4 31 PM 212V031 Screw 5 16 x 1 1 4 4 32 PM 212V032 Pulley 1 33 PM 212V033 Screw 6 x 8 1 34 PM 212V034 V Belt Cover 1 35 PM 212V035 Screw 1 4 x 3 8 4 36 PM 212V036 Screw 1 37 PM 212V037 Scre...

Page 16: ...aring 6201 1 71 PM 212V071 Rubber Washer Ø40 1 63 75 PM 212V072K Spindle Ass y 1 73 944477 Wedge 1 74 PM 212V074 Ball Bearing 6204 1 76 100188 Taper Mandrel MK2 B18 1 77 9473 SS Chuck 1 13mm 1 78 PM 212V078 Flange 1 79 PM 212V079 Cover 1 80 PM 212V080 Screw 3 16 x 3 8 6 81 PM 212V081 Micro Switch 1 82 PM 212V082 Emergency Stop 1 83 PM 212V083 Chip Guard Ass y 1 83A PM 212V083A Glass 1 83H PM 212V0...

Page 17: ...P Plug for supply Three phase LIAN DUNG LT 32 10 16A 250V Supply cable single phase TIEN TUNG H05VV F 3G 1 5mm2 300 500V VDE 0620 SB1 Start switch KM 240V 10A SB2 OFF Emergency Stop Switch KM 240V 10A SB3 Emergency Stop switch XINQUANG KB2 BE102 10A SQ1 Micro switch Zhejiang Tiande CT 103 250V 10A SQ2 Micro switch HIEHLY CLS 103 220V 10A ...