9
Mounting the Inlet Guard Assembly
Referring to Figure 4:
1. Position the inlet guard assembly over the dust
port, and push it down until the holes (V) align.
2. Insert the provided 4mm tapping screw through
the holes using a screwdriver. Tighten it securely.
Filter Bag Kit Assembly
If you purchased Model DC-650BK or DC-650MK Dust
Collector, this section describes the assembly and
installation of the contents of the Filter Bag Kit
(SN 708642B and 708642MF).
Filter Bag Installation
Referring to Figure 5:
1. Thread an M6
hex nut
onto the filter bag
support
rod
(B), followed by an M6
flat washer
and M6
lock
washer
(A). Thread the
support rod
(B) into the
motor/fan housing and tighten nut against the
housing using a 10 wrench.
2. Place
the
retaining strap
(C) through the loops on
the filter bag and hang the filter bag from the hook.
3. Secure bag to housing with retaining strap.
Note:
The retainer strap should be tight enough to
provide a good seal.
Collector Bag Installation (30 Micron Kit)
1. Insert
the
snap ring
of
collector bag
into the bottom
of
housing
at an angle (Figure 5).
2. Pull down on the ring and bag to make sure it
“seats” in the housing.
Collector Bag Installation (5 Micron Kit)
The 5-Micron Filter Bag Kit includes clear plastic
collector bags. Refer to Figures 8 and 9 on the next
page, along with the accompanying instructions, to
install these.
After completing the filter bag and collector bag
installation, proceed to
Electrical Connections
.
Figure 4
Figure 5
Figure 6