background image

 

14

Changing Operating Frequency 

If several devices are controlled by the same type 
remote control unit, each remote control unit can be 
set to operate at its' own unique operating frequency 
as follows: 

Referring to Figure 15: 

1.  Unplug the DC-RC230 

Remote Power Control 

unit. 

2.  Remove the back covers of the 

main unit

 (A) and 

remote control switch

 (B). 

3. Locate 

the 

DIP switch

 (C) in each unit. 

4.  Change the position of the DIP switches in the 

main unit 

(A) to any combination desired as long 

as they are not the same as other units that may 
be present and located within the radio frequency 
range. 

5. Set the 

DIP

 

switches

 (C) in the 

remote control 

switch

 (B) to match the switch settings in the 

main unit

 (A). 

6.  Replace the back covers to the main unit and 

remote control switch. 

7.  Operate a device as described in 

Turning the 

DC-RC230 On & Off

 and verify that other devices 

using the same type remote control do not turn 
on. 

 

Figure 15 

 

Installing the DC-RC Remote Power 
Control 

The 

DC-RC230 Remote Power Control

 unit can be 

placed anywhere for convenience and portability if 
used to control other machines or it can be mounted 
as a permanent part of a machine, such as the DC-
1200 Dust Collector. 

To mount the 

DC-RC230 Remote Power Control 

(refer to Figure 16): 

Note:

 Mounting hardware is not included and must 

be supplied by the machine’s owner or user. 

1. Place 

RC Power Control Unit

 (A) on the open 

clearing of the 

base

 (B) of the dust collector near 

the 

motor

 (C). 

2.  Using a marker, mark the base through the 

mounting holes of the power control units 
mounting tabs. 

3.  Drill two holes (D) through the base where 

marked. 

4.  Insert screws through the tabs and base. Place 

washers and hex nuts on the threaded ends of 
the screw underneath the base and tighten. 

 

 

Figure 16 

Summary of Contents for DC-1200BK

Page 1: ...ector DC 1200 Series Dust Collectors DC 1200BK DC 1200CK WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Part No M 710700 Ph 800 274 6848 Revision B 11 2010 www waltermeier com Copyright 2010 Walter Meier Manufacturing Inc ...

Page 2: ...age prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must accompany the merchandise If our inspection discloses a defect we will repair or replace the product or refund the purchase price at our option We will return the repaired product or replacement at ou...

Page 3: ...13 All Models 13 Remote Control Optional Accessory 13 Turning the DC RC230 On Off 13 Changing Operating Frequency 14 Installing the DC RC Remote Power Control 14 Maintenance 15 Cleaning the Filter Bag DC 1200BK and DC 1200BK 3 15 Removing the Collector Bag DC 1200BK and DC 1200BK 3 15 Cleaning the Canister Filter DC 1200CK and DC 1200CK 3 15 Removing the Collector Bag DC 1200CK and DC 1200CK 3 15 ...

Page 4: ...rystalline silica from bricks cement and other masonry products Arsenic and chromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as face or dust masks that are specifically designed to filter out microscopic particles...

Page 5: ...mes to a complete stop 28 Remove loose items and unnecessary work pieces from the area before starting the machine 29 Never place hands near the inlet of the machine 30 Always make certain machine is off and unplugged when making any connections to the inlet Familiarize yourself with the following safety notices used in this manual This means that if precautions are not heeded it may result in min...

Page 6: ...in 20 Collector Bag Capacity cu ft 5 3 Collector Bag Length installed in 29 Canister Filter Kit Stock Number 708639B Canister Length in 25 Canister Efficiency 86 of 1 micron particles 98 of 2 micron particles Collector Bag Diameter in 20 Collector Bag Capacity cu ft 5 3 Collector Bag Length installed in 29 5 Micron Filter Bag Kit Optional Accessory Stock Number 708636MF Filter Bag Efficiency 98 of...

Page 7: ...00BK x x DC 1200CK x x DC 1200BK 3 x x DC 1200CK 3 x x Table DC 1200 Dust Collector cartons Hardware Bag for Base Unit SN DC1100 HP 16 M8 x 16 Hex Cap Screws K 22 M8 Flat Washers L 08 M6 x 12 Pan Head Flange Screws M 06 M8 Hex Nuts N Base Assembly Hardware Hardware Bag for Cone Assembly SN DC1100 HP2 1 M8 x 16 Hex Cap Screw O 1 M8 Flat Washer P 1 M8 Hex Nut R 4 M6 x 12 Hex Cap Screws S 4 M6 Hex Nu...

Page 8: ...er Kit Contents Canister Filter Hardware SN DC1100 CHP Canister Filter Hardware 30 Micron Bag Filter Kit SN 708636F 1 Upper Bag Hanger Y 1 Hanger Bracket Z 1 Collector Bag X 1 Filter Bag W 1 Retainer Strap AA 30 Micron Bag Filter Kit Contents 5 Micron Bag Filter Kit Optional SN 708636MF 1 Upper Bag Hanger BB 1 Hanger Bracket CC 1 Filter Bag DD 5 Collector Bags EE 1 Retainer Strap FF 1 Snap Ring GG...

Page 9: ...r each M8 x 16 hex cap screws and M8 flat washers B Tighten with a 13mm wrench The dust collector must not be connected to the power source during assembly Failure to comply may result in serious injury Referring to Figure 3 4 Attach impeller cover A to fan housing D using eight M6 x 12 pan head screws B Press the inlet ports C onto the inlet guard until it snaps into place To reduce the risk of i...

Page 10: ... to the housing with four M6x12 hex cap screws F and tighten from beneath with four M6 hex nuts G 9 Install the cone H from beneath using the M8x16 hex cap screw J M8 flat washer K and M8 hex nut L and tighten Hose Referring to Figure 7 10 Attach the hose B between the fan housing A and the impeller housing D with two clamps C Tighten the clamps to secure the hose This completes the Base Unit asse...

Page 11: ... Slide the filter bag loop C over the hanger hook 3 Feed the retainer strap D through the loops on the filter bag E and fasten to the collector housing F Collector Bag Installation Referring to Figure 9 4 Insert the ring of the collector bag A at an angle into the housing B through the opening at the bottom Pull down on the bag to make sure it seats in the housing 5 Position the plastic window in ...

Page 12: ...on top of the collector housing A Fig 5 and tighten the knobs on the canister filter Figure 10 Collector Bag 3 Place the ring over the top of the plastic bag and fold over the bag approximately three inches Figure 11 4 Insert the snap ring A Fig 12 of the collector bag into the bottom of the housing at an angle 5 Pull down on the ring to make sure it seats in the housing Note make sure the snap ri...

Page 13: ...wer Control unit is available as an optional accessory contact Customer Service by calling the number on the cover Important The DC RC230 Remote Power Control can be used for activating Dust Collection units powered by 230V only up to 3HP single phase only Figure 13A Figure 13B Dust Collector RF Remote Power Control optional The DC RC230 Remote Power Control Figure 14 should be used for activating...

Page 14: ...erate a device as described in Turning the DC RC230 On Off and verify that other devices using the same type remote control do not turn on Figure 15 Installing the DC RC Remote Power Control The DC RC230 Remote Power Control unit can be placed anywhere for convenience and portability if used to control other machines or it can be mounted as a permanent part of a machine such as the DC 1200 Dust Co...

Page 15: ...in maximum performance with JET s dust hoods hoses clamps fittings and blast gates Cleaning the Canister Filter DC 1200CK and DC 1200CK 3 Never perform maintenance on this machine before turning switch off and removing plug from power source Failure to comply may cause serious injury Clean both the filter and collector bags frequently to keep the collector s performance at its optimum To clean the...

Page 16: ...16 Parts Breakdown for the DC 1200 Dust Collector ...

Page 17: ...ord 3 Ph 1 9 420051 Motor Packing 1 10 AB411059 Impeller 12 1 11 411036W Inlet Guard 1 12 427028 Inlet Port 2 4 1 13 420203 Inlet Cap 2 14 430034 Inlet Flange Packing 1 15 411041W Base 1 16 402036 Pivoting Caster 4 17 420012W Housing 1 18 402004W Support 3 20 411009 Hose 5 x65 CM 1 21 420010 Ring Clamp 5 2 31 ST039304 Tapping Screw M3 5x12 AB 6 32 KS050525 Key 5x5x25 1 34 TS 1540061 Nut M8 10 35 T...

Page 18: ...not shown 1 DC1100 HP Hardware Package not shown 1 DC1100 HP2 Hardware Package for cone assy index 49 thru 53 1 DC1200A CS Centrifugal Switch not shown 1 DC1900 53 Warning Label not shown 1 DC1200 53 Grounding Label not shown 1 DC1200 54 Direction Label not shown 1 ...

Page 19: ...t Grip Handle 2 9 TS 1540041 Hex Nut M6 8 10 708739 Filter 1 11 331052 Shaft 1 12 TS 1482041 Hex Cap Screw M6X20 4 13 TS 2361061 Lock Washer M6 4 14 TS 1550041 Flat Washer M6 4 15 331012 Scraper 2 16 331017 Strip 2 17 331015 Press Plate 2 18 TS 1482021 Hex Cap Screw M6x12 4 19 331037 Knob 4 20 331031 Pad 1 21 331009 Support 1 22 ST049200 Tapping Screw M4X8 4 23 331038 Snap Ring 1 24 709563 Plastic...

Page 20: ...Filter Bag Assembly Index No Part No Description Size Qty 1 708698 Filter Bag 30 Micron Bag 1 2 AB410012 Retainer Strap 1 3 708699A Collection Bag 1 4 430038 Hanger 30 Micron Bag Hanger 1 5 523011W Hanger Bracket 1 ...

Page 21: ...dex No Part No Description Size Qty 708636MF 5 Micron Filter and Collection Bag Kit index 1 6 1 708706 Filter Bag 5 Micron 1 2 AB410012 Retainer Strap 1 3 331038 Snap Ring 1 4 709563 Plastic Bag Package of 5 1 5 430038 Hanger 1 6 523011W Hanger Bracket 1 ...

Page 22: ...22 Wiring Diagram For 3 Phase 230V 460V Dust Collector DC 1200M 3 Wiring Diagram For Single Phase 230V Only Dust Collector DC 1200M ...

Page 23: ...23 ...

Page 24: ...24 WALTER MEIER Manufacturing Inc 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www waltermeier com ...

Reviews: