Cold Metals Lab
V1.0 11/7/2017
To adjust the vise for angle cutting:
•
Loosen bolts and move vise jaw ( C ) to desired location.
•
Set the vise to desired angle, re-install nuts and tighten the nut and bolt assemblies.
•
Adjust the movable vise parallel to the fixed vise by loosening bolt (D) adjusting to parallel, and
re-tightening bolt.
Controls
•
Power Indicator Light (A)
–
lit whenever machine is running.
•
Start Button (B)
–
press to start band saw.
•
Emergency Stop Button (C)
–
press to immediately stop all machine functions.
•
Coolant Switch (D)
–
Turn arrow to “I” to turn on coolant flow. Turn arrow to “O” to stop coolant
flow.
•
Cutting Pressure Control (E)
–
turn clockwise to decrease cutting pressure. Turn counter-
clockwise to increase cutting pressure.
•
Hydraulic On-Off Valve (F)
–
turns hydraulic cylinder on and off.