Jet 952 Installation Instructions Manual Download Page 3

FIGURE 3

UV INSERT INSTALLATION

1.  Place the 1” Schedule 40 PVC pipe  

 

in the coupler of the UV insert to help  
determine where the 1” pipe should be  
trimmed so that it is easily reached when  
in the riser.

2.  Remove the 1” Schedule 40 PVC pipe    

from the coupler and trim it.  

3.  Glue the single side of the union to one    

end of the 1” PVC pipe.  See figure 3.     

The opposite end will already be glued    
to the bushing on the control  

 

 

panel UV lamp wire.

4.  Glue the other end of the 1” PVC pipe    

into the coupler that is on the  

 

 

UV insert.

5.  Using a soft clean cloth moistened with    

isopropyl alcohol wipe off the quartz  

 

tube.

6.  Gently set the UV insert in the UV  

 

housing using the lifting handle.  Be  

 

sure that the Kapton edges curl into  

 

the openings in the keyway shown in 

      Figure 4.

JET Model 952 UV Disinfection 

Device Installation Instructions

FIGURE 4

Summary of Contents for 952

Page 1: ...g components should be supplied by the installer 1 All Purpose Cement 2 Clear Cleaner for plastics 3 Drill with Universal Bit 4 Clean soft cloth 5 Isopropyl alcohol 6 Small slotted screwdriver 7 Wire...

Page 2: ...not flow through the device correctly and the UV disinfection will not be effective See Figure 1 2 Clean the ends of the upstream and downstream piping and the hubs of the UV cross with clear plastic...

Page 3: ...of the 1 PVC pipe See figure 3 The opposite end will already be glued to the bushing on the control panel UV lamp wire 4 Glue the other end of the 1 PVC pipe into the coupler that is on the UV insert...

Page 4: ...remaining lead to the common C terminal WIRE THE CONTROL PANEL 1 The UV unit operates on 120 VAC single phase power A 15 amp circuit breaker on the main electrical panel should be used for the UV dis...

Page 5: ...the disinfection chamber and riser until even with the final grade being no more than 6 below the bottom of the control panel 11 Turn the UV disinfection device on at the main electrical panel 12 The...

Page 6: ...hose Water in Enclosure Enclosure cover not secure Conduit hub not secure Align and tighten enclosure cover Tighten conduit hub Lamp Active Light Not Lit No power from main breaker panel No power to U...

Page 7: ...ure to follow the suggestions outlined in any associated product documentation or Owners Manuals Items normally consumed in service such as fuses filter cartridges spin plates grease oil etc are not w...

Reviews: