Jet 550610 Operations & Parts Manual Download Page 6

JCT-2610 Series Rivet Buster

 

Setup and Assembly 

Any missing parts or damage should be reported 
immediately to your JET

®

 distributor. Do not use a 

damaged tool. Read this instruction manual 
thoroughly for operation, maintenance and safety 
instructions. 

Box contents: 

1 Rivet 

buster 

1 Screw 

clamp 

Operation and parts manual  

1 Warranty 

card 

 

Figure 1 

1.  Rotate exhaust deflector (Figure 1) until 

exhaust holes point away from operator and 
bystanders.  

2. 

Install screw clamp on exhaust deflector to 
secure its position. 

Operation 

 

The rivet buster must be 

properly lubricated before operation. See 
“Lubrication” section.

 

1.  Install working steel (not provided) as 

follows. See Figure 2. 

2. 

Place screwdriver or other tool in triangular 
end of retainer spring, and pull spring out of 
groove. 

3. 

Slide retainer off cylinder. If needed, insert 
screwdriver into slot and use as wedge to 
help loosen retainer. 

4. 

Lubricate shank of working steel with grease. 
Insert steel through rear of retainer. (Make 

sure upper sleeve is fitted into cylinder, and 
lower sleeve and bumper are fitted into 
retainer.) 

5. 

Slide steel and retainer onto cylinder. Shank 
of steel should be fully inserted into cylinder, 
and retainer slot should align with groove on 
cylinder.  

 

Figure 2 (chisel not provided) 

6. 

Install spring by feeding it into groove until 
completely installed. If needed, spray 
lubricant into groove to facilitate spring 
insertion. Tug sharply on the working steel to 
ensure it is secure. 

 

An unsecured steel can 

be ejected from the cylinder with force, 
causing injury. Retainer and retainer 
spring must be properly installed before 
using rivet buster.

 

7. 

Remove protective cap from air inlet (Figure 
1). If an in-line oiler is not being used, add 4 
or 5 drops of air tool oil (not included) into the 
air inlet. 

8.  Blow out air line to remove any dirt or 

moisture, then connect air supply hose to 
tool. Set air pressure to 90 psi. 

IMPORTANT:

 Connecting a quick-change 

coupling directly to the tool is not 
recommended, as vibration may cause the 
connection to fail. Instead, add a leader hose 
and install any quick-change couplings 
farther down the line. 

9.  Hold rivet buster firmly with both hands. 

Place end of tool in contact with work 
surface, and press throttle lever. Do not push 
too hard; allow tool to do the work.  

10.  Release throttle lever to stop tool. 

Summary of Contents for 550610

Page 1: ...Buster 550610 JCT 2610 550611 JCT 2611 550612 JCT 2612 Operation Parts Manual M 550610 Edition 1 07 2016 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2016 JET...

Page 2: ...rsenic and chromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated are...

Page 3: ...or best and safest performance 32 Do not use combustible gases carbon dioxide oxygen or any bottled gas as an air source for the tool These can present risk of explosion and serious injury 33 Do not l...

Page 4: ...rnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of oper...

Page 5: ...279mm 22 1 2 in 572mm 20 1 2 in 522mm Handle D style drop forged Retainer style Jumbo 11X Housing material Steel Required oil Air Tool Oil or ISO VG32 SAE 10W equivalent Net weight 33 lb 15 kg 30 lb...

Page 6: ...fitted into retainer 5 Slide steel and retainer onto cylinder Shank of steel should be fully inserted into cylinder and retainer slot should align with groove on cylinder Figure 2 chisel not provided...

Page 7: ...ms Always oil the tool and disconnect air hose before storage Air system requirements 1 Use proper air hose size refer to tool specifications The hose should be just long enough to serve the working a...

Page 8: ...the main distribution line Use moisture traps and in line oilers on each downline that is to be used for air tools See Figure 4 Place oiler as close to air tool as possible for best lubrication Lubri...

Page 9: ...ns in this manual Loss of power erratic action Low air pressure or air volume Verify compressor has proper CFM rating for tool Check compressor regulator setting set air pressure to 90 psi Check for l...

Page 10: ...n or bushing is damaged Inspect and replace elements as needed Blockage in valve area Remove any foreign matter Steel tool is loose Steel shank does not match retainer bushing Use steel with correct s...

Page 11: ...CT2610 08 Throttle valve plug 1 9 JCT2610 09 Throttle valve pin 1 10 JCT2610 10 Valve pin bushing 1 JCT2610 VA Valve assembly 11 15 1 11 JCT2610 11 Valve case 1 12 JCT2610 12 Valve 1 Index Part No Des...

Page 12: ...pring 1 8 JCT2610 08 Throttle valve plug 1 9 JCT2610 09 Throttle valve pin 1 10 JCT2610 10 Valve pin bushing 1 JCT2610 VA Valve assembly 11 15 1 11 JCT2610 11 Valve case 1 12 JCT2610 12 Valve 1 Index...

Page 13: ...2610 08 Throttle valve plug 1 9 JCT2610 09 Throttle valve pin 1 10 JCT2610 10 Valve pin bushing 1 JCT2610 VA Valve assembly 11 15 1 11 JCT2610 11 Valve case 1 12 JCT2610 12 Valve 1 Index Part No Descr...

Page 14: ...ith any additional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Servic...

Page 15: ...JET 15 This page intentionally left blank...

Page 16: ...16 JCT 2610 Series Rivet Buster 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...

Reviews: