Jet 505921 Operations & Parts Manual Download Page 10

10 

JAT-920 Pneumatic Riveter 

 

Troubleshooting JAT-920 Pneumatic Riveter

 

Any disassembly of the tool should be done by qualified service personnel. For problems not addressed 
below, contact JET technical service at 800-274-6846. 

Problem 

Possible cause 

Remedy 

Riveting force insufficient. 

Air valve obstructed. 

Clear any obstructions. 

Low air pressure. 

Verify compressor has proper CFM 
rating for tool. 
Check compressor regulator 
setting; set air pressure to 90 psi.   
Check for loose connections.  

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
If problem persists, disassemble, 
clean and lubricate internal parts. 

Internal components are worn. 

Replace worn components.  

Trigger or trigger lever is 
malfunctioning. 

Inspect and repair trigger and/or 
trigger lever. 

Riveter stops operating. 

No air pressure. 

Check air compressor and hoses. 
Make sure compressor is set at 
90psi, and air lines are not twisted. 

Trigger or trigger lever is 
malfunctioning. 

Inspect and repair trigger and/or 
trigger lever. 

Insufficient pulling action. 

Air valve obstructed. 

Clear any obstructions. 

Low air pressure. 

Verify compressor has proper CFM 
rating for tool. 
Check compressor regulator 
setting; set air pressure to 90 psi.   
Check for loose connections.  

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
If problem persists, disassemble, 
clean and lubricate internal parts. 

Jaws slipping. 

Obstruction in jaw area. 

Clean jaw parts. 

Worn jaws or jaw spring. 

Replace parts as needed. 

Loose jaw case. 

Tighten. 

Short stroke. 

Incorrect size rivet. 

Use proper rivet for hole. 

Insufficient lubrication. 

Lubricate according to instructions. 

Jaws will not open. 

Dirty jaws or loose nosepiece. 

Clean or tighten as needed. 

Slow piston return. 

Obstruction in cylinder. 

Disassemble and clean cylinder. 

Fires immediately as soon 
as air is connected. 

Trigger or trigger lever is 
malfunctioning. 

Inspect and repair trigger and/or 
trigger lever. 

Severe air leakage. 
(Note: Minimal escape of 
air is often normal for air 
tools.) 

Air valve obstructed or damaged. 

Clean or replace. 

O-rings damaged. 

Replace 0-rings 

Housing loose or damaged. 

Tighten or replace as needed. 

Summary of Contents for 505921

Page 1: ...Pneumatic Riveter 505921 JAT 920 Operation Parts Manual M 505921 Edition 1 11 2018 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2018 JET...

Page 2: ...eeded JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET...

Page 3: ...against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired or under the influence of drugs alcohol or any medicatio...

Page 4: ...eter without safety cap installed as mandrel may be expelled from the tool forcefully causing injury 36 Do not install rivets close to the edge of a work surface as it may cause workpiece to split cau...

Page 5: ...ion of your tool on the cover of this manual for quick access Retain this manual for future reference If the tool transfers ownership the manual should accompany it Tool specifications Model number JA...

Page 6: ...re 2 3 Push new nosepiece into jaws against the spring tension and rotate until threads engage Tighten nosepiece with wrench 4 Remove protective cap from air inlet Figure 1 If an in line oiler is not...

Page 7: ...sassembled jaw case jaw halves jaw pusher and the spring 4 Clean each of the disassembled parts Use a cleaning brush on the internal threads of the jaw and inside the rivet head 5 Reassembled parts in...

Page 8: ...e of the tool Air System Recommendations Equip the air compressor intake with a replaceable air filter that can be easily cleaned Use safety shut off valves so air flow can be stopped quickly in case...

Page 9: ...JET 9 Figure 3 Recommended arrangement of air piping and air line system...

Page 10: ...t and repair trigger and or trigger lever Insufficient pulling action Air valve obstructed Clear any obstructions Low air pressure Verify compressor has proper CFM rating for tool Check compressor reg...

Page 11: ...llowing pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available wh...

Page 12: ...12 JAT 920 Pneumatic Riveter 505921 JAT 920 Pneumatic Riveter exploded view...

Page 13: ...2 26 706 20 Back up ring P12 1 27 706 22 Frame lock nut 1 Index Part No Description Qty 28 JAT920 28B Rubber cushion 1 29 JAT920 29B Air cylinder 1 30 1 706 25 Air piston stem 1 30 2 JAT920 30 2B Air...

Page 14: ...14 JAT 920 Pneumatic Riveter This page intentionally left blank...

Page 15: ...JET 15 This page intentionally left blank...

Page 16: ...16 JAT 920 Pneumatic Riveter 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...

Reviews: