Auto-dialer interface 

The circuit board has a 
connector configured to 
provide power and a 
triggering signal to select 
models of commercial, 
automatic telephone voice 
dialers.  If an Auto-Dialer is 
installed on the model 197 
Control Panel use wire ties 
to secure RJ-10 cable to 
LED array mounting posts to 

ensure there is no contact 
between the RJ-10 cable 
and 197 control panel 
printed circuit board or 
components

  (see image at 

right) 
 
 

RS232 interface circuit 

An interface circuit for RS232 
communications allows for 
connection of the panel to a 
computer or other data logging 
equipment.  If this equipment is 
connected to the model 197 Control 
Panel use wire ties to secure RS232 
cable to LED array mounting posts to 

ensure there is no contact 
between the RS232 cable and 197 
control panel printed circuit board 
or components

  (see image at 

below). 
 
 
 
 

Fuse and power switch 

The power to the on-board circuitry and to the auxiliary outputs is fused and there 
is an on-board power switch for use by service or maintenance personnel. 

Summary of Contents for 197

Page 1: ...ircuits Three auxiliary output circuits Three auxiliary input circuits with normally open or normally closed selection One power indicator LED and four additional error indicator LED s An alarm buzzer with circuit board provision for an alternate or externally mounted buzzer A 9 position DIP switch for selection of configuration options User accessible reset switch and circuit board master reset s...

Page 2: ...L PANEL MAINTAIN ALL SAFETY DECALS Install ground and wire according to local and National Electrical Code Requirements Disconnect and lockout electrical power before installing or servicing the control panel Electrical supply must match nameplate specifications inside of the control panel Incorrect voltage can cause fire damage control panel and void the warranty All single phase pump motors and ...

Page 3: ...ove grade entrance to the house is recommended if the control panel is mounted inside the dwelling If direct burial cable is used conduit should be in place from the beginning of the foundation to the entrance of the dwelling 5 Jet recommends burying cable and conduit at least two feet deep to prevent accidental damage to the external wiring 6 Proper procedures and solvents must be used to protect...

Page 4: ... Carlon or T B liquidtight non metallic conduit and fittings for field installations Sample instructions have been provided refer to the proper model connector fitting instructions provided by the manufacturer for exact installation instuctions 5 Assure that all connections are properly installed and watertight 6 Pull all cables and wiring through the conduit and connectors into the control panel ...

Page 5: ... system components and the panel 13 If an integrated pump control is desired the model 197 control panel is equipped with an internal pump control relay The pump should always be operated on an independent circuit The pump control relay is designed to supply continuous power to the pump circuit provided there is not an active alarm condition In the event of an alarm state the pump control relay wi...

Page 6: ... a wrench tighten compression nut one quarter 1 4 turn past hand tight Do not over tighten fitting To prevent damage to conductors conduit and fittings do not twist Carflex during installation LT43D New LT43E New LT20D New LT20E New 1 Cut the end of the Carflex conduit or Carflex X Flex tubing square 2 Install compression nut over the end of the conduit or tubing 3 Insert the ferrule end of the fi...

Page 7: ...Off 15 min On On Off On 40 min Off 20 min Off Off On On 35 min Off 25 min On Off On On 30 min Off 30 min On On On Continuous Run Switch Four Inactive Auxiliary Output Control Switch Five Switch Six Auxiliary Alarm Function Off Off All Outputs Inactive On Off Output One Active Off On Outputs One and Two Active On On All Outputs Active Multiple Aerator Controls Switch Seven Toggle multiple aeration ...

Page 8: ...e circuit is will not function properly the program enters a one hour delay cycle If the circuit cannot function properly after the one hour delay cycle the power control relay for the corresponding aerator circuit is turned off and the panel enters the alarm condition which is indicated by a flashing LED and central alarm beacon and an audible signal If so equipped the panel will also signal an a...

Page 9: ...h no error conditions present only the blue power indicator LED will be on Auxiliary alarm circuits should be properly labeled on the wiring diagram or control panel cover Alarm buzzer The alarm buzzer sounds when an error condition exists There is circuit board provision for an externally mounted or alternate model buzzer When power is initially turned on the buzzer will sound for second to confi...

Page 10: ...d 197 control panel printed circuit board or components see image at right RS232 interface circuit An interface circuit for RS232 communications allows for connection of the panel to a computer or other data logging equipment If this equipment is connected to the model 197 Control Panel use wire ties to secure RS232 cable to LED array mounting posts to ensure there is no contact between the RS232 ...

Page 11: ...eaker panel for all of the system circuits Turn on the control panel power the self test should alarm for two seconds then all alarms should return to normal state The blue indicator light should now indicate that there is power to the panel and circuits Check to make sure all system components are operational If a pump is connected to the system it may not immediately function depending on additi...

Page 12: ...rnal devices and floats No Power to Aerators Inbound power inactive Timer setting in Off cycle Check connections and main breaker panel Reset panel to override Off cycle No Power to Pump Inbound power inactive Alarm condition active Check connections and main breaker panel Resolve alarm conditions Auxiliary Outputs Inactive DIP settings incorrect Excessive load on external device Check DIP setting...

Page 13: ...ing Diagram Refer to the wiring diagram below when connecting aerators compressors pumps and auxiliary equipment to the Jet model 197 control panels Note The location of the terminal blocks has been re formatted for this manual and does not exactly correspond to the location of the terminal blocks on the circuit board ...

Page 14: ...cted to external damage III damaged due to improper or altered wiring or overload protection or IV damaged by failure to follow the suggestions outlined in any associated product documentation or Owners Manuals Items normally consumed in service such as fuses filter cartridges spin plates grease oil etc are not warranted This warranty applies only to the Jet system components supplied by Jet Inc a...

Reviews: