28. Maintenance and safety check
This unit should be serviced in regular intervals dependent on Operating times and working place conditions.
Before opening the machine switch off the plug!
- Clean unit inside by vacuum cleaner according to degree of soiling.
Attention:
This Welding unit has to be safety checked every year by Jäckle & Ess System GmbH Company or another
special qualified electrician according to the
harmonized standard
IEC 60974 – 4
Safety, maintenance and inspection of arc welding equipment in use
29. Remote control socket (Option)
Pin
Name
Description
A / 1
Actual volt-
age
(U-actual)
Output signal between 0V and +10 V.
The ratio between welding voltage and signal voltage is 10:1.
Example: 40V welding voltage = 4.0V signal voltage
Input impedance should be ≥ 10k. The reference potential is pin 3
B / 2
Actual cur-
rent
(I-actual)
Output signal between 0V and +10 V.
The ratio between welding current and signal voltage is 100:1.
Example: 100A welding current = 1V signal voltage
Input impedance should be ≥ 10k. The reference potential is Pin 3
C / 3
GND
Ground potential for Pin 1, 2, 4, 5
D / 4
Master (U)-
voltage 2
Input signal for the function of EC 2
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
E / 5
Master (U)-
voltage 1
Input signal for the function of EC 1
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
F / 6
+10V
+10V reference voltage output for potentiometer control Pin 4, 5
The maximum output current is 10mA.
G / 7
+24V
+24V reference output voltage for the switch signals Pin 8, 9, 10
The maximum output current is 10mA
H / 8
T – BT
MIG / TIG torch trigger input signal, supply to pin 7
Start signal for automation.
J / 9
T – up
Input signal for an up / down torch, here the increasing (up) signal, supply to pin 7
K / 10 T – down
Input signal for an up / down torch, here the decreasing (down) signal, supply to pin
7
L / 11 Current flow
Potential-free contact. If a current flow is detected, the contact is closed.
The contact opens when the current flow is interrupted.
Maximum voltage 48V, maximum current 1A
M / 12 Current flow
13-17 free
Not used!
For more information on the circuit diagram.
Summary of Contents for ProTIG 350AC/DC
Page 2: ...ProTIG 350 AC DC...
Page 3: ......
Page 22: ...ProTIG 350 AC DC Bedienungsanleitung Seite 18...
Page 26: ...ProTIG 350 AC DC Operating manual Page 22...
Page 27: ...ProTIG 350 AC DC Operating manual Page 23...
Page 48: ...ProTIG 350 AC DC Operating manual Page 44 Seitenansichten side view ProTIG 350...
Page 51: ...ProTIG 350 AC DC Operating manual Page 47...
Page 52: ......