Jesco MULTI-LINX MLX Series Installation Instructions Manual Download Page 2

MLX

MULTI-LINX LED Fixture

Modular Linkable Linear Fixture

www.jescolighting.com

[email protected]

Tech Support: 

855.592.0029

Instruction sheet subject to change without prior notice.

15 Harbor Park Drive

Port Washington, NY 11050

Main Line: 

800.527.7796

Fax Line:

 855.265.5768

219 South 6th Ave

City of Industry, CA 91746

Main Line: 

855.654.0110

Fax Line

: 626.333.2955

Designed, Developed and

Assembled in the U .S.A

Page 2 of 8

JW 06/14/2017

MULTI-LINX

MLX-24 18”(46cm)  |  MLX-48 44”(112cm)  |  MLX-96 88”(224cm)

Recommended MLX-MC Spacing:

PLASTIC ANCHOR

MLX-MC

#8 SELF-TAPPING SCREW

DRILL 1/4” HOLE

MASONRY

DRYWALL/CEILING TILE

MLX-PC(05/10)

MLX-PC-HW(05/10)

MLX

MLX

MLX- MEC

Locking Screw

METAL STUD

WOOD

DRILL 1/8” HOLE

MLX-MC

MLX-DC

OR

MLX-CC-06/12/18

INPUT

OUTPUT

END FEED

TOP FEED

#8 SELF-TAPPING SCREW

MLX-PC(05/10)-TF

MLX-PC-HW(05/10)-TF

MLX- MEC

MLX- FEC

BLACK to BLACK

WHITE to WHITE

GREEN or COPPER to GREEN 

SUPPLY WIRES

 

INPUT

OUTPUT

MLX

MLX

CABLE SUSPENSION (LINEARLY CONNECTED) INSTALLATION INSTRUCTIONS

PLASTIC ANCHOR

COUPLER MOUNT 

MOUNTING  SCREW

DRILL 1/4” HOLE

DRILL 1/8” HOLE

COUPLER

COUPLER

CABLE GRIP

T-NUT MOUNT

CABLE 

COUPLER MOUNT 

MOUNTING SCREW

BLACK (HOT)

WHITE (NEUTRAL)

GREEN 

OR COPPER 

(GROUND)

SUPPLY WIRES

A-A

B-B

MLX-PC-HW(05/10)

MLX-PC-HW(05/10)-TF

 

MLX-PC (05/10)

MLX-PC (05/10)-TF

MLX-24 18”(46cm)  |  MLX-48 44”(112cm)  |  MLX-96 88”(224cm)

Recommended MLX-SCK Spacing:

MLX-SCK 

C

C1

C1

C2

C2

CABLE

C3

CABLE

C3

COUPLER MOUNT 

COUPLER

C1

C2

C3

C4

C5

MASONRY

DRYWALL/CEILING TILE

METAL STUD

WOOD

TOOLS REQUIRED

HARDWARE INCLUDED 

with MLX-SCK

REQUIRED COMPONENTS FOR SINGLE FIXTURE INSTALLATION

ADDITIONAL COMPONENTS REQUIRED FOR CONNECTING MULTIPLE FIXTURES

MINI PHILLIPS 

SCREWDRIVER

1

 

A-A

 Plug in      MLX-PC or MLX-PC-HW into       MLX fixture’s 

input port and secure power connector to fixture with 
provided mounting screws with a mini-phillips screwdriver. 

1 B-B      

Top feed cable is pre-wired onto      MLX fixture 

Single Pendant

 

Installation

 

End feed fixture Insert:       MLX-MEC into       MLX’s output 
port. Top feed fixture insert:       MLX-MEC into       MLX’s 
output port and insert      MLX-FEC into       MLX’s input port.

Multiple Fixtures

 

Installation

 Insert  (1)      MLX-DC or (1)     

MLX-CC to the output connection of all connecting fixtures. 
For the last connecting fixture.  Insert      MLX-MEC to the 

output connection.  

2

 Based on building material of intended mounting surface, 

determine the best mounting method. Each      MLX fixture 
requires (2)       MLX-SCK for installation, recommended 
distance between each      MLX-SCK is determined by
      MLX fixture’s length. 

2 A-A 

Drill a 1/4” hole in mounting surface and make sure 

the depth is at least 1/4” past the length of the plastic 
anchor.  Insert plastic anchor in drilled hole.  Insert mounting 
screw through       COUPLER MOUNT and screw into plastic 
anchor. Repeat the process for second      COUPLER MOUNT, 
then secure       COUPLER with       CABLE to       COUPLER 
MOUNT by hand.

2 B-B 

Drill a 1/8” pilot hole and fasten mounting screw and

      COUPLER MOUNT on to mounting surface. Repeat the 
process for second       COUPLER MOUNT.

SUSPENSION WI

TH CABLES

Single or Multiple fixtures connected

linearly.

MLX-PC(05/10)

MLX-PC-HW(05/10)

MLX-PC(05/10)-TF

MLX-PC-HW(05/10)-TF

MLX-(24/48/96)

MLX-DC

with

MLX-CC-(06/12/18)

MLX-DCS

OR

MLX-SCK-(1/2)

MLX-MEC

MLX-FEC

required for top 

feed (-TF) input

MOUNTING SCREWS 

WIRE CUTTER

PLASTIC ANCHOR

FOR USE WITH DRYWALL

2

A-A

B-B

POWER DRILL WITH: 

1/4” DRILL BIT

1/8” DRILL BIT

PHILLIPS BIT

A

B

C

D

E

F

G

H

1

B

B

A

A

E

D

D

B

B

A

A

A

A

A

A

C

C

C1

C1

C1

C1

C1

C2

C3

A

D

E

F

H

D

D

A-A

B-B

Continue on page 3 ---->

Summary of Contents for MULTI-LINX MLX Series

Page 1: ...structions Read completely before beginning If you feel you do not have adequate electrical wiring experience have this installed by a qualified licensed electrician All electrical connections must be...

Page 2: ...r MLX PC HW into MLX fixture s input port and secure power connector to fixture with provided mounting screws with a mini phillips screwdriver 1 B B Top feed cable is pre wired onto MLX fixture Single...

Page 3: ...5 B B Connect second MLX fixture via input port to direct connector in first MLX fixture 5 C C Slide RIGID PLATE and T NUT BAR to the center of 2 connected MLX fixtures Tighten nuts on T Bar with a N...

Page 4: ...SUPPLY WIRES MLX 24 18 46cm MLX 48 44 112cm MLX 96 88 224cm Recommended MLX SCK Spacing MLX SCK C C1 C1 C2 C2 CABLE C3 CABLE C3 COUPLER MOUNT COUPLER C1 C2 C3 C4 C5 MASONRY DRYWALL CEILING TILE METAL...

Page 5: ...de by side making sure all input ports are together on one side and all output ports are on the other Align and place MLX XB over T NUT secure MLX XB with NUT using a NUT DRIVER 3 Insert 2 T NUT onto...

Page 6: ...4 102mm T NUT MLX FBCON MLX FBCON MLX PC 5 10 MLX PC HW 5 10 NUT T NUT H3 H1 H2 H3 H F H1 H2 H3 MLX X A MLX XB 2 3 4 5 6 B A B E D G G F INPUT OUTPUT 110V B 110V B 110V B 110V B 110V G G G G G G G D...

Page 7: ...BLACK SUPPLY WIRES INPUT OUTPUT MLX MLX TOOLS REQUIRED HARDWARE REQUIRED REQUIRED COMPONENTS FOR SINGLE FIXTURE INSTALLATION ADDITIONAL COMPONENTS REQUIRED FOR CONNECTING MULTIPLE FIXTURES MINI PHILL...

Page 8: ...BLACK HOT WHITE NEUTRAL GREEN OR COPPER GROUND SUPPLY WIRES A A B B MLX PC HW 05 10 MLX PC HW 05 10 TF MLX PC 05 10 MLX PC 05 10 TF MLX 24 18 46cm MLX 48 44 112cm MLX 96 88 224cm Recommended MLX SCK S...

Reviews: