Jesco MULTI-LINX MLX Series Installation Instructions Manual Download Page 1

INSTALLATION INSTRUCTIONS

MLX

MULTI-LINX LED Fixture

Modular Linkable Linear Fixture

www.jescolighting.com

[email protected]

Tech Support: 

855.592.0029

Instruction sheet subject to change without prior notice.

15 Harbor Park Drive

Port Washington, NY 11050

Main Line: 

800.527.7796

Fax Line:

 855.265.5768

219 South 6th Ave

City of Industry, CA 91746

Main Line: 

855.654.0110

Fax Line

: 626.333.2955

Designed, Developed and

Assembled in the U .S.A

Page 1 of 8

JW 06/14/2017

MULTI-LINX

Please read and save these instructions. Read carefully before using product.  Protect yourself and others by observing all 

safety information, warnings and cautions.  Failure to comply with instructions could result in personal injury and/or damage 

to product or property.   Please retain instruction sheet for future reference.

IMPORTANT SAFETY INSTRUCTIONS 

Read completely before beginning. If you feel you do not have adequate electrical wiring experience, have this installed by 

a qualified licensed electrican.

All electrical connections must be in accordance with local codes, ordinances and the National Electric Code.  This product 

operates on 120V AC; always confirm the maximum wattage of the linear fixture does not exceed the maximum wattage of 

the circuit it is connected to. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified 

licensed electrician.

Read and follow all safety instructions.
Read completely before beginning.  If you feel you do not have adequate electrical wiring experience, have this 

installed by a qualified licensed electrician.

All electrical connections must be in accordance with local codes, ordinances and the National Electric Code.  

This product operates on 120V AC; always confirm the maximum wattage of the linear fixture does not exceed the 

maximum wattage of the circuit it is connected to. If you are unfamiliar with methods of installing electrical wiring, 

secure the services of a qualified licensed electrician.
Do not install the linear fixture if any damage is seen on the product or power cables.

Prior to starting the installation, disconnect the power by turning off the circuit breaker or removing the appropriate 

fuse.  (Turning off power using the light switch is not sufficient to prevent electrical shock).

1.
2.

3.

4.
5.

TURN OFF ELECTRICITY 

at main fuse box (or circuit breaker box) 

before beginning installation by switching 

circuit breaker off or removing fuse. 

MIN 90º C SUPPLY CONDUCTORS.

MOUNTING OPTIONS

FOR ELECTRICAL CONNECTION, SEE PAGE 8

Surface Mounting

 

with Clips

Single or Multiple fixtures connected

linearly. (See page 7)

Single or Linearly Connected

Ceiling Mounting with Cables

Single or multiple fixtures connected 

linearly. (See page 2)

Multiple Side-by-Side

Ceiling Mounting with Cables

Multiple fixtures connected side-by-side.

(See page 4)

RATED 120 VOLT AC

20W per 2 feet fixture (15units MAX)

40W per 4 feet fixture (7 units MAX)

80W per 8 feet fixture (3 units MAX)

CONSULT A QUALIFIED ELECTRICIAN TO 

ENSURE CORRECT BRANCH CIRCUIT

300W MAX

connected run

Summary of Contents for MULTI-LINX MLX Series

Page 1: ...structions Read completely before beginning If you feel you do not have adequate electrical wiring experience have this installed by a qualified licensed electrician All electrical connections must be...

Page 2: ...r MLX PC HW into MLX fixture s input port and secure power connector to fixture with provided mounting screws with a mini phillips screwdriver 1 B B Top feed cable is pre wired onto MLX fixture Single...

Page 3: ...5 B B Connect second MLX fixture via input port to direct connector in first MLX fixture 5 C C Slide RIGID PLATE and T NUT BAR to the center of 2 connected MLX fixtures Tighten nuts on T Bar with a N...

Page 4: ...SUPPLY WIRES MLX 24 18 46cm MLX 48 44 112cm MLX 96 88 224cm Recommended MLX SCK Spacing MLX SCK C C1 C1 C2 C2 CABLE C3 CABLE C3 COUPLER MOUNT COUPLER C1 C2 C3 C4 C5 MASONRY DRYWALL CEILING TILE METAL...

Page 5: ...de by side making sure all input ports are together on one side and all output ports are on the other Align and place MLX XB over T NUT secure MLX XB with NUT using a NUT DRIVER 3 Insert 2 T NUT onto...

Page 6: ...4 102mm T NUT MLX FBCON MLX FBCON MLX PC 5 10 MLX PC HW 5 10 NUT T NUT H3 H1 H2 H3 H F H1 H2 H3 MLX X A MLX XB 2 3 4 5 6 B A B E D G G F INPUT OUTPUT 110V B 110V B 110V B 110V B 110V G G G G G G G D...

Page 7: ...BLACK SUPPLY WIRES INPUT OUTPUT MLX MLX TOOLS REQUIRED HARDWARE REQUIRED REQUIRED COMPONENTS FOR SINGLE FIXTURE INSTALLATION ADDITIONAL COMPONENTS REQUIRED FOR CONNECTING MULTIPLE FIXTURES MINI PHILL...

Page 8: ...BLACK HOT WHITE NEUTRAL GREEN OR COPPER GROUND SUPPLY WIRES A A B B MLX PC HW 05 10 MLX PC HW 05 10 TF MLX PC 05 10 MLX PC 05 10 TF MLX 24 18 46cm MLX 48 44 112cm MLX 96 88 224cm Recommended MLX SCK S...