to avoid the danger of physical injury and corrosion at the dosing pump. Leaking
chemicals may also damage the diaphragm pump at its mounting points.
CAUTION!
• When changing the chemical medium, check whether the pump and the system’s
materials of construction are chemically resistant. If there is danger of a chemical
reaction between different media, a thorough cleaning is first mandatory.
IMPORTANT!
• After adjusting the stroke length, the locking screw must be retightened. Otherwise
the adjusting knob may change its position. Thus causing irregular flow rates.
CAUTION!
• The base area of the dosing pump must be kept clear to allow sufficient air circula-
tion to cool the motor down. If there is a danger of fluid collecting underneath the
base of the pump, the pump must be elevated.
DANGER!
• Fire hazard. Pressure surge: catapulting parts could kill you. MIDIDOS E must not be
used under any circumstances in an explosive environment.
1.12 Scope of delivery
IMPORTANT!
Please unpack the dosing pump and ordered accessories with great care in order not to
miss any small parts. Immediately compare the scope of delivery with the delivery note.
The cause of any discrepancies must be determined.