![Jesco MAGDOS LK Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/jesco/magdos-lk/magdos-lk_operating-instructions-manual_3808024019.webp)
Hydraulic installation
Connecting a leakage drain
19
© Lutz-Jesco GmbH 2015
Subject to technical changes.
150225
BA-10221-02-V03
Stepper Motor-driven Diaphragm Dosing Pump
MAGDOS LK
Operating Instructions
8.5 Connecting a leakage drain
Lutz-Jesco GmbH dosing pumps are produced to the highest quality
standards and have a long service life. However, some parts are subject
to operational wear. This is the case particularly with the diaphragms that
are continuously subjected to forces during the suction and discharge
strokes and to the effects of the dosing medium.
If a diaphragm ruptures, the dosing medium starts to leak. This leakage is
drained via the leakage opening. On the flange of the dosing head, there
are three openings for this purpose. Depending on the alignment of the
dosing pump, the leakage is drained via the downward opening.
Fig. 14: Openings of the leakage drain
NOTICE
Damage to drives due to effervescent media
If a hose is connected to the leakage drain and it is routed back into
the dosing tank, effervescent media can enter the drive and damage
it.
ð
Collect the leakage in a collecting pan.
ð
As an alternative, you can route the leakage back to to the dosing
tank using a funnel. You should install the funnel at an adequate
distance from the leakage opening.
8.6 Connecting the dosing head venting facility
The MAGDOS LK dosing heads have an integrated dosing head venting
facility (except for dosing heads made of stainless steel).
For the procedure when venting, refer to “Venting the dosing pump” on
page 34.
Fig. 15: Dosing head venting facility with hose connection
Perform the following working steps:
1.
Connect a 4/6 hose to the dosing head venting facility.
2.
Route the other end of the hose into the dosing tank or a collecting
tank.
ü
Dosing head venting facility connected.