7.6 Injection nozzle installation
Injection nozzles are used to mix the metered process fluid into a main stream and simultaneously fulfill a
non-return function. The injection nozzle is usually installed in the main line from above. Installation from
below is only recommended in the case of media with a tendency to crystallize. Thus entrapped air is able
to leave.
In the case of media with a tendency to contaminate the injection nozzle, it is advisable to use an injection
nozzle which can be dismantled for maintenance and shut off.
Injection fitting mounted from above
Injection nozzle mounted from below
(for media with a tendency to crystallize)
Fig. 7.4: Injection nozzle installation
7.7 Installation example/ Example for accessories
Excerpt of the comprehensive metering technology acessory program of the manufacturer.
Mounting of the MAGDOS LB on a container with a container adapter.
a
MAGDOS LB
b
Chemical tank
c
Suction line
d
Priming aid
e
Electric agitator
f
Pulsation dampener
g
Injection nozzle with non-return and shutoff valve
h
back-pressure valve
⑨
Pressure relief valve (safety valve)
j
Container adapter
Mul-
tifunction valve PENTABLOC (without figure)
Fig. 7.5: Example of installation of a dosing pump with accessories
2
1
3
4
5
6
7
8
9
1
12