5. Technical data
MAGDOS DE/DX 01...100
Unit 01 03
07
2
4
8
12
20
40 100
Delivery rate at max. pressure *
l/h
0.1 0.46 0.72 1.86 3.9 6
12 20.2 50.4 115
Max. delivery pressure *
bar
10
6
10
10 10 10
4
10
4
1.5
max. stroke frequency
rpm
100
70
Suction head for non-gassing media
m
water
col.
3
2
1.2
Max. supply pressure
(∑ static and dynamic)
mbar
800
700 400 200 100
0
Voltage supply
V AC
115 or 230. +/- 10 %. 50/60 Hz
Power cable
2 m cable with:
- Shock-proof plug. 230 V AC
- with UL/CSA connector. 115 V AC
Power consumption
230 V AC
W
21
30
70
115 V AC
33
66
Max. current consumption
during dosing stroke
230 V AC
A
2.3
4.1
115 V AC
3.6
7.4
Soldered fuse
230 V AC
A
T 0.8
T 2
115 V AC
T 1.6
T 4
Protection class
IP 65
Insulation class
F
Input pulse duration
ms
> 30
Solenoid excitation time
per pulse
230 V AC
ms
60
160
115 V AC
80
190
Fault signalling relay
with changeover contact
(optional)
230 V AC
A
2.5
115 V AC
2.5
Voltage, level monitoring connection
V DC
5. for potential-free switching outputs
Voltage, pulse input
V DC
5. for potential-free switching outputs
Load for 0/4...20 mA input
Ω
150
Max. ambient temperature
°C
40
Max. temperature of the medium
°C
50 (35 with PVC parts)
Weight
Plastic
kg
2.9 approx.
10.5
12.5
Stainless steel
3.5 approx.
12
20
Max. sound pres. level, depressurised dB(A)
58
66
61
Max. sound pres. level at test pres.
dB(A)
60
68
62
* The precise metered quantities can be derived from the Delivery Characteristic Curves, Section 6.
Technical data | Operation & Maintenance Instructions |