Recommended Operation:
Mixers installed on tanks with existing sediment accumulation should be operated continuously as
long as oil level is above 10 feet (3 meters) and sediment content in outgoing stream is acceptable.
Angle variation from full left to full right and to center should be made periodically – once each month
during continuous running. Recommended positions –30º to –5º to 30º then repeat
For effective sediment control on clean tanks, start mixer 8 hours before pump-out. Continue until
tank is half full. This procedure will need to be modified to suit climate and conditions. In controlling
sediment, angle variation need be made only about once each month.
Periodic Maintenance:
WEEKLY: Observe Center Sight Glass on Sentry System for fluid, this will be indication of seal issues.
WEEKLY: Check external moving parts for abnormal wear.
MONTHLY: With the mixer running, check for noise and vibration. (See Troubleshooting if occurs)
MONTHLY or AS NEEDED: Check belt defection and wear. Be sure the pulleys are not worn and are clean.
QUARTERLY: Grease hinge zerk if Jensen Actuator is installed.
Tenney Company
www.tenneyco.com
For Jensen Mixer Parts - Call 281-350-1200